87 research outputs found

    Three-Dimensional-Printed Drill Guides for Occipitothoracic Fusion in a Pediatric Patient With Occipitocervical Instability

    Get PDF
    BACKGROUND: Pediatric occipitothoracic fusion can be challenging because of small size pedicles and thin occipital bone. Three-dimensional (3D) printing technology can help with accurate screw insertion but has not been described for occipital keel plate positioning so far. OBJECTIVE: To describe the novel use of 3D technology to position occipital keel plates during pediatric occipitothoracic fixation. METHODS: A young boy with segmental spinal dysgenesis presented with asymmetrical pyramidal paresis in all limbs. Developmental abnormities of the cervical spine caused a thinned spinal cord, and because of progressive spinal cord compression, surgical intervention by means of occipitothoracic fixation was indicated at the age of 3 yr. Because of the small-size pedicles and thin occipital bone, the pedicle screws and occipital plates were planned meticulously using 3D virtual surgical planning technology. The rods were virtually bent in order to properly align with the planned screws. By means of 3D-printed guides, the surgical plan was transferred to the operating theater. For the occipital bone, a novel guide concept was developed, aiming for screw positions at maximal bone thickness. RESULTS: The postoperative course was uneventful, and radiographs showed good cervical alignment. After superimposing the virtual plan with the intraoperative acquired computed tomography, it was confirmed that the occipital plate positions matched the virtual plan and that pedicle screws were accurately inserted without signs of breach. CONCLUSION: The use of 3D technology has greatly facilitated the performance of the occipitothoracic fixation and could, in the future, contribute to safer pediatric spinal fixation procedures

    Clockwise Torque of Sliding Hip Screws: Is There a Right Side?

    Get PDF
    OBJECTIVES: This study evaluated whether patients with a left-sided femoral neck fracture (FNF) treated with a sliding hip screw (SHS) had a higher implant failure rate than patients treated for a right-sided FNF. This was performed to determine the clinical relevance of the clockwise rotational torque of the femoral neck lag screw in a SHS, in relation to the rotational stability of left and right-sided FNFs after fixation. METHODS: Data were derived from the FAITH trial and Dutch Hip Fracture Audit (DHFA). Patients with a FNF, aged ≥50, treated with a SHS, with at least 3-month follow-up data available, were included. Implant failure was analyzed in a multivariable logistic regression model adjusted for age, sex, fracture displacement, prefracture living setting and functional mobility, and American Society for Anesthesiologists Class. RESULTS: One thousand seven hundred fifty patients were included, of which 944 (53.9%) had a left-sided and 806 (46.1%) a right-sided FNF. Implant failure occurred in 60 cases (3.4%), of which 31 were left-sided and 29 right-sided. No association between fracture side and implant failure was found [odds ratio (OR) for left vs. right 0.89, 95% confidence interval (CI) 0.52-1.52]. Female sex (OR 3.02, CI: 1.62-6.10), using a mobility aid (OR 2.02, CI 1.01-3.96) and a displaced fracture (OR 2.51, CI: 1.44-4.42), were associated with implant failure. CONCLUSIONS: This study could not substantiate the hypothesis that the biomechanics of the clockwise screw rotation of the SHS contributes to an increased risk of implant failure in left-sided FNFs compared with right-sided fractures. LEVEL OF EVIDENCE: Therapeutic Level II.See Instructions for Authors for a complete description of levels of evidence

    The legacy of ZikaPLAN: a transnational research consortium addressing Zika

    Get PDF
    Global health research partnerships with institutions from high-income countries and low- and middle-income countries are one of the European Commission's flagship programmes. Here, we report on the ZikaPLAN research consortium funded by the European Commission with the primary goal of addressing the urgent knowledge gaps related to the Zika epidemic and the secondary goal of building up research capacity and establishing a Latin American-European research network for emerging vector-borne diseases. Five years of collaborative research effort have led to a better understanding of the full clinical spectrum of congenital Zika syndrome in children and the neurological complications of Zika virus infections in adults and helped explore the origins and trajectory of Zika virus transmission. Individual-level data from ZikaPLAN`s cohort studies were shared for joint analyses as part of the Zika Brazilian Cohorts Consortium, the European Commission-funded Zika Cohorts Vertical Transmission Study Group, and the World Health Organization-led Zika Virus Individual Participant Data Consortium. Furthermore, the legacy of ZikaPLAN includes new tools for birth defect surveillance and a Latin American birth defect surveillance network, an enhanced Guillain-Barre Syndrome research collaboration, a de-centralized evaluation platform for diagnostic assays, a global vector control hub, and the REDe network with freely available training resources to enhance global research capacity in vector-borne diseases

    Discomfort in children undergoing unsedated MRI

    Get PDF
    Magnetic resonance imaging (MRI) scans for research purposes usually do not directly benefit the children scanned, so that review boards need to assess whether the risk of harm or discomfort is minimal. This study aimed at providing empirical data on discomfort related to unsedated MRI in children aged 5–12 years. Secondary objectives were to determine whether lower age is associated with higher levels of discomfort and to investigate which other characteristics of subjects and/or procedures may be associated with higher levels of discomfort. Self-report scores, observation scores, heart rate standard deviation scores, and incremental salivary cortisol levels were obtained from 54 children aged 5–12 years with non-acute conditions undergoing diagnostic MRI. Of the 54 children, 10 scored relatively high values on the self-report score and on one or two of the other measures, and another 15 scored relatively high on the self-report score alone. Rather than an age effect, associations were found between parents’ trait anxiety and observation score values and between use of contrast fluid (requiring the insertion of a venous cannula) and high incremental salivary cortisol levels. In conclusion, MRI-related discomfort may be regarded as minimal for more than half of children aged 5–12

    Automatic radiographic quantification of hand osteoarthritis; accuracy and sensitivity to change in joint space width in a phantom and cadaver study

    Get PDF
    This is the final version of the article. Available from Springer Verlag via the DOI in this record.OBJECTIVE: To validate a newly developed quantification method that automatically detects and quantifies the joint space width (JSW) in hand radiographs. Repeatability, accuracy and sensitivity to changes in JSW were determined. The influence of joint location and joint shape on the measurements was tested. METHODS: A mechanical micrometer set-up was developed to define and adjust the true JSW in an acrylic phantom joint and in human cadaver-derived phalangeal joints. Radiographic measurements of the JSW were compared to the true JSW. Repeatability, systematic error (accuracy) and sensitivity (defined as the smallest detectable difference (SDD)) were determined. The influence of joint position on the JSW measurement was assessed by varying the location of the acrylic phantom on the X-ray detector with respect to the X-ray beam and the influence of joint shape was determined by using morphologically different human cadaver joints. RESULTS: The mean systematic error was 0.052 mm in the phantom joint and 0.210 mm in the cadaver experiment. In the phantom experiments, the repeatability was high (SDD = 0.028 mm), but differed slightly between joint locations (p = 0.046), and a change in JSW of 0.037 mm could be detected. Dependent of the joint shape in the cadaver hand, a change in JSW between 0.018 and 0.047 mm could be detected. CONCLUSIONS: The automatic quantification method is sensitive to small changes in JSW. Considering the published data of JSW decline in the normal and osteoarthritic population, the first signs of OA progression with this method can be detected within 1 or 2 years.This work was funded by the Dutch Arthritis Association (Reumafonds). The study sponsor had no involvement in study design, data collection, data analysis, or interpretation of the results
    • …
    corecore