10 research outputs found

    Long-Term Results from an Epiretinal Prosthesis to Restore Sight to the Blind

    Get PDF
    PurposeRetinitis pigmentosa (RP) is a group of inherited retinal degenerations leading to blindness due to photoreceptor loss. Retinitis pigmentosa is a rare disease, affecting only approximately 100 000 people in the United States. There is no cure and no approved medical therapy to slow or reverse RP. The purpose of this clinical trial was to evaluate the safety, reliability, and benefit of the Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) in restoring some visual function to subjects completely blind from RP. We report clinical trial results at 1 and 3 years after implantation.DesignThe study is a multicenter, single-arm, prospective clinical trial.ParticipantsThere were 30 subjects in 10 centers in the United States and Europe. Subjects served as their own controls, that is, implanted eye versus fellow eye, and system on versus system off (native residual vision).MethodsThe Argus II System was implanted on and in a single eye (typically the worse-seeing eye) of blind subjects. Subjects wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina.Main Outcome MeasuresThe primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests.ResultsA total of 29 of 30 subjects had functioning Argus II Systems implants 3 years after implantation. Eleven subjects experienced a total of 23 serious device- or surgery-related adverse events. All were treated with standard ophthalmic care. As a group, subjects performed significantly better with the system on than off on all visual function tests and functional vision assessments.ConclusionsThe 3-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind from RP. Earlier results from this trial were used to gain approval of the Argus II by the Food and Drug Administration and a CE mark in Europe. The Argus II System is the first and only retinal implant to have both approvals

    Transcriptomic Analysis of Human Retinal Detachment Reveals Both Inflammatory Response and Photoreceptor Death

    Get PDF
    Background Retinal detachment often leads to a severe and permanent loss of vision and its therapeutic management remains to this day exclusively surgical. We have used surgical specimens to perform a differential analysis of the transcriptome of human retinal tissues following detachment in order to identify new potential pharmacological targets that could be used in combination with surgery to further improve final outcome. Methodology/Principal Findings Statistical analysis reveals major involvement of the immune response in the disease. Interestingly, using a novel approach relying on coordinated expression, the interindividual variation was monitored to unravel a second crucial aspect of the pathological process: the death of photoreceptor cells. Within the genes identified, the expression of the major histocompatibility complex I gene HLA-C enables diagnosis of the disease, while PKD2L1 and SLCO4A1 -which are both down-regulated- act synergistically to provide an estimate of the duration of the retinal detachment process. Our analysis thus reveals the two complementary cellular and molecular aspects linked to retinal detachment: an immune response and the degeneration of photoreceptor cells. We also reveal that the human specimens have a higher clinical value as compared to artificial models that point to IL6 and oxidative stress, not implicated in the surgical specimens studied here. Conclusions/Significance This systematic analysis confirmed the occurrence of both neurodegeneration and inflammation during retinal detachment, and further identifies precisely the modification of expression of the different genes implicated in these two phenomena. Our data henceforth give a new insight into the disease process and provide a rationale for therapeutic strategies aimed at limiting inflammation and photoreceptor damage associated with retinal detachment and, in turn, improving visual prognosis after retinal surgery

    TREATMENT OF SUBRETINAL PERFLUOROCARBON LIQUID BUBBLES COMPLICATING RETINAL DETACHMENT SURGERY USING AIR FOR DRAINAGE

    No full text
    PURPOSE: The authors describe an original technique for treating multiple subretinal perfluorocarbon liquid (PFCL) bubbles complicating previous surgery for rhegmatogenous retinal detachment. METHODS: To facilitate the induction of macular redetachment and peripheral displacement of the PFCL bubbles, we performed the subretinal injection of filtered air in addition to balanced salt solution. In this setting, the action of the PFCL in the vitreous cavity, combined with globe manipulation, allowed bubbles' displacement and full aspiration. RESULTS: A 57-year-old man had a history of repeated pars plana vitrectomies for recalcitrant rhegmatogenous retinal detachment, the latter leading to multiple subretinal PFCL bubbles retained at the posterior pole. The described technique was performed 8 weeks after the last pars plana vitrectomy. A complete flattening of the macular region was obtained with visual improvement. CONCLUSION: Direct injection of air into the subretinal space may represent an effective strategy to help the surgical management of multiple retained PFCL bubbles

    TREATMENT OF MACULAR FOLDS COMPLICATING RETINAL DETACHMENT SURGERY USING AIR FOR RETINAL UNFOLDING

    No full text
    We discuss a modified surgical procedure for the treatment of macular folds complicating retinal reattachment surgery

    Choroidal and peripapillary changes in high myopic eyes with Stickler syndrome

    No full text
    International audienceBackground: To compare different clinical and Spectral-Domain Optical Coherence Tomography (SD-OCT) features of high myopic eyes with Stickler syndrome (STL) with matched controls.Methods: Patients with genetically confirmed STL with axial length ≥ 26 mm and controls matched for axial length were included. The following data were obtained from SD-OCT scans and fundus photography: choroidal and retinal thickness (respectively, CT and RT), peripapillary atrophy area (PAA), presence of posterior staphyloma (PS).Results: Twenty-six eyes of 17 patients with STL and 25 eyes of 19 controls were evaluated. Compared with controls, patients with STL showed a greater CT subfoveally, at 1000 μm from the fovea at both nasal and temporal location, and at 2000 and 3000 μm from the fovea in nasal location (respectively, 188.7±72.8 vs 126.0±88.7 μm, 172.5±77.7 vs 119.3±80.6 μm, 190.1±71.9 vs 134.9±79.7 μm, 141.3±56.0 vs 98.1±68.5 μm, and 110.9±51.0 vs 67.6±50.7 μm, always P< 0.05). Furthermore, patients with STL showed a lower prevalence of PS (11.5% vs 68%, P< 0.001) and a lower PAA (2.2±2.1 vs 5.4±5.8 mm2, P=0.03), compared with controls.Conclusions: This study shows that high myopic patients with STL show a greater CT, a lower PAA and a lower prevalence of PS, compared with controls matched for axial length. These findings could be relevant for the development and progression of myopic maculopathy in patients with STL

    Five-Year Safety and Performance Results from the Argus II Retinal Prosthesis System Clinical Trial

    Get PDF
    PurposeThe Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) was developed to restore some vision to patients blind as a result of retinitis pigmentosa (RP) or outer retinal degeneration. A clinical trial was initiated in 2006 to study the long-term safety and efficacy of the Argus II System in patients with bare or no light perception resulting from end-stage RP.DesignProspective, multicenter, single-arm clinical trial. Within-patient controls included the nonimplanted fellow eye and patients' native residual vision compared with their vision with the Argus II.ParticipantsThirty participants in 10 centers in the United States and Europe.MethodsThe worse-seeing eye of blind patients was implanted with the Argus II. Patients wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina.Main Outcome MeasuresThe primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests. Secondary measures included functional vision performance on objectively scored real-world tasks.ResultsTwenty-four of 30 patients remained implanted with functioning Argus II Systems at 5 years after implantation. Only 1 additional serious adverse event was experienced after the 3-year time point. Patients performed significantly better with the Argus II on than off on all visual function tests and functional vision tasks.ConclusionsThe 5-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind as a result of RP. The Argus II is the first and only retinal implant to have market approval in the European Economic Area, the United States, and Canada
    corecore