1,026 research outputs found

    Flow properties of a series of experimental thermoplastic polymides

    Get PDF
    The softening temperature to degradation temperature range of the polymers was about 440 to 650 K. All of the polymers retained small amounts of solvent as indicated by an increase in T(sub g) as the polymers were dried. The flow properties showed that all three polymers had very high apparent viscosities and would require high pressures and/or high temperatures and/or long times to obtain adequate flow in prepregging and molding. Although none was intended for such application, two of the polymers were combined with carbon fibers by solution prepregging. The prepregs were molded into laminates at temperatures and times, the selection of which was guided by the results from the flow measurements. These laminates had room temperature short beam shear strength similar to that of carbon fiber laminates with a thermosetting polyimide matrix. However, the strength had considerable scatter, and given the difficult processing, these polymides probably would not be suitable for continuous fiber composites

    HERMIES-3: A step toward autonomous mobility, manipulation, and perception

    Get PDF
    HERMIES-III is an autonomous robot comprised of a seven degree-of-freedom (DOF) manipulator designed for human scale tasks, a laser range finder, a sonar array, an omni-directional wheel-driven chassis, multiple cameras, and a dual computer system containing a 16-node hypercube expandable to 128 nodes. The current experimental program involves performance of human-scale tasks (e.g., valve manipulation, use of tools), integration of a dexterous manipulator and platform motion in geometrically complex environments, and effective use of multiple cooperating robots (HERMIES-IIB and HERMIES-III). The environment in which the robots operate has been designed to include multiple valves, pipes, meters, obstacles on the floor, valves occluded from view, and multiple paths of differing navigation complexity. The ongoing research program supports the development of autonomous capability for HERMIES-IIB and III to perform complex navigation and manipulation under time constraints, while dealing with imprecise sensory information

    Biomedical research leaders: report on needs, opportunities, difficulties, education and training, and evaluation.

    Get PDF
    The National Association of Physicians for the Environment (NAPE) has assumed a leadership role in protecting environmental health in recent years. The Committee of Biomedical Research Leaders was convened at the recent NAPE Leadership Conference: Biomedical Research and the Environment held on 1--2 November 1999, at the National Institutes of Health, Bethesda, Maryland. This report summarizes the discussion of the committee and its recommendations. The charge to the committee was to raise and address issues that will promote and sustain environmental health, safety, and energy efficiency within the biomedical community. Leaders from every important research sector (industry laboratories, academic health centers and institutes, hospitals and care facilities, Federal laboratories, and community-based research facilities) were gathered in this committee to discuss issues relevant to promoting environmental health. The conference and this report focus on the themes of environmental stewardship, sustainable development and "best greening practices." Environmental stewardship, an emerging theme within and outside the biomedical community, symbolizes the effort to provide an integrated, synthesized, and concerted effort to protect the health of the environment in both the present and the future. The primary goal established by the committee is to promote environmentally responsible leadership in the biomedical research community. Key outcomes of the committee's discussion and deliberation were a) the need for a central organization to evaluate, promote, and oversee efforts in environmental stewardship; and b) immediate need to facilitate efficient information transfer relevant to protecting the global environment through a database/clearinghouse. Means to fulfill these needs are discussed in this report

    Management of Intracranial Meningiomas Using Keyhole Techniques

    Get PDF
    BACKGROUND: Keyhole craniotomies are increasingly being used for lesions of the skull base. Here we review our recent experience with these approaches for resection of intracranial meningiomas. METHODS: Clinical and operative data were gathered on all patients treated with keyhole approaches by the senior author from January 2012 to June 2013. Thirty-one meningiomas were resected in 27 patients, including 9 supratentorial, 5 anterior fossa, 7 middle fossa, 6 posterior fossa, and 4 complex skull base tumors. Twenty-nine tumors were WHO Grade I, and 2 were Grade II. RESULTS: The mean operative time was 8 hours, 22 minutes (range, 2:55-16:14) for skull-base tumors, and 4 hours, 27 minutes (range, 1:45-7:13) for supratentorial tumors. Simpson Resection grades were as follows: Grade I = 8, II = 8, III = 1, IV = 15, V = 0. The median postoperative hospital stay was 4 days (range, 1-20 days). In the 9 patients presenting with some degree of visual loss, 7 saw improvement or complete resolution. In the 6 patients presenting with cranial nerve palsies, 4 experienced improvement or resolution of the deficit postoperatively. Four patients experienced new neurologic deficits, all of which were improved or resolved at the time of the last follow-up. Technical aspects and surgical nuances of these approaches for management of intracranial meningiomas are discussed. CONCLUSIONS: With careful preoperative evaluation, keyhole approaches can be utilized singly or in combination to manage meningiomas in a wide variety of locations with satisfactory results

    The STAR Time Projection Chamber: A Unique Tool for Studying High Multiplicity Events at RHIC

    Full text link
    The STAR Time Projection Chamber (TPC) is used to record collisions at the Relativistic Heavy Ion Collider (RHIC). The TPC is the central element in a suite of detectors that surrounds the interaction vertex. The TPC provides complete coverage around the beam-line, and provides complete tracking for charged particles within +- 1.8 units of pseudo-rapidity of the center-of-mass frame. Charged particles with momenta greater than 100 MeV/c are recorded. Multiplicities in excess of 3,000 tracks per event are routinely reconstructed in the software. The TPC measures 4 m in diameter by 4.2 m long, making it the largest TPC in the world.Comment: 28 pages, 11 figure

    Neglected patellar tendon rupture: a case of reconstruction without quadriceps lengthening

    Get PDF
    Neglected rupture of the patellar tendon is a rare, can be easily missed in a group of patients. We present a 24 year old, male patient who sustained right femoral diaphyseal and tibial plateau fractures and a patellar tendon rupture following a motor vehicle accident. The fractures were treated by open reduction internal fixation but the patellar tendon rupture was missed and the diagnosis was delayed by 7 months. Patella was migrated proximally. It was moved distally to the original location and neglected patellar tendon rupture treated successfully with modified Ecker technique. Neither preoperative traction nor additional intraoperative procedures were performed to relocate the patella to its anatomic position in the extended knee and good functional result was achieved with intensive rehabilitation

    The American Association for the Surgery of Trauma renal injury grading scale: Implications of the 2018 revisions for injury reclassification and predicting bleeding interventions.

    Get PDF
    BackgroundIn 2018, the American Association for the Surgery of Trauma (AAST) published revisions to the renal injury grading system to reflect the increased reliance on computed tomography scans and non-operative management of high-grade renal trauma (HGRT). We aimed to evaluate how these revisions will change the grading of HGRT and if it outperforms the original 1989 grading in predicting bleeding control interventions.MethodsData on HGRT were collected from 14 Level-1 trauma centers from 2014 to 2017. Patients with initial computed tomography scans were included. Two radiologists reviewed the scans to regrade the injuries according to the 1989 and 2018 AAST grading systems. Descriptive statistics were used to assess grade reclassifications. Mixed-effect multivariable logistic regression was used to measure the predictive ability of each grading system. The areas under the curves were compared.ResultsOf the 322 injuries included, 27.0% were upgraded, 3.4% were downgraded, and 69.5% remained unchanged. Of the injuries graded as III or lower using the 1989 AAST, 33.5% were upgraded to grade IV using the 2018 AAST. Of the grade V injuries, 58.8% were downgraded using the 2018 AAST. There was no statistically significant difference in the overall areas under the curves between the 2018 and 1989 AAST grading system for predicting bleeding interventions (0.72 vs. 0.68, p = 0.34).ConclusionAbout one third of the injuries previously classified as grade III will be upgraded to grade IV using the 2018 AAST, which adds to the heterogeneity of grade IV injuries. Although the 2018 AAST grading provides more anatomic details on injury patterns and includes important radiologic findings, it did not outperform the 1989 AAST grading in predicting bleeding interventions.Level of evidencePrognostic and Epidemiological Study, level III

    A Compton-vetoed germanium detector with increased sensitivity at low energies

    Get PDF
    The difficulty to directly detect plutonium in spent nuclear fuel due to the high Compton background of the fission products motivates the design of a Gamma detector with improved sensitivity at low energies. We have built such a detector by operating a thin high-purity Ge detector with a large scintillator Compton veto directly behind it. The Ge detector is thin to absorb just the low-energy Pu radiation of interest while minimizing Compton scattering of high energy radiation from the fission products. The subsequent scintillator is large so that forward scattered photons from the Ge detector interact in it at least once to provide an anti-coincidence veto for the Ge detector. For highest sensitivity, additional material in the line-of-sight is minimized, the radioactive sample is kept thin, and its radiation is collimated. We will discuss the instrument design, and demonstrate the feasibility of the approach with a prototype that employs two large CsI scintillator vetoes. Initial spectra of a thin Cs-137 calibration source show a background suppression of a factor of {approx}2.5 at {approx}100 keV, limited by an unexpectedly thick 4 mm dead layer in the Ge detector

    Electromagnetic Transthoracic Nodule Localization for Minimally Invasive Pulmonary Resection

    Get PDF
    Background: Increased use of chest computed tomography and the institution of lung cancer screening have increased the detection of ground-glass and small pulmonary nodules. Intraoperative localization of these lesions via a minimally invasive thoracoscopic approach can be challenging. We present the feasibility of perioperative transthoracic percutaneous nodule localization using a novel electromagnetic navigation platform. Methods: This is a multicenter retrospective analysis of a prospectively collected database of patients who underwent perioperative electromagnetic transthoracic nodule localization before attempted minimally invasive resection between July 2016 and March 2018. Localization was performed using methylene blue or a mixture of methylene blue and the patient's blood (1:1 ratio). Patient, nodule, and procedure characteristics were collected and reported. Results: Thirty-one nodules were resected from 30 patients. Twenty-nine of 31 nodules (94%) were successfully localized. Minimally invasive resection was successful in 93% of patients (28/30); 7% (2/30) required conversion to thoracotomy. The median nodule size was 13 mm (interquartile range 25%-75%, 9.5-15.5), and the median depth from the surface of the visceral pleura to the nodule was 10 mm (interquartile range 25%-75%, 5.0-15.9). Seventy-one percent (22/31) of nodules were malignant. No complications associated with nodule localization were reported. Conclusions: The use of intraoperative electromagnetic transthoracic nodule localization before thoracoscopic resection of small and/or difficult to palpate lung nodules is safe and effective, potentially eliminating the need for direct nodule palpation. Use of this technique aids in minimally invasive localization and resection of small, deep, and/or ground-glass lung nodules
    • …
    corecore