619 research outputs found

    Electromagnetic Simulation and Design of a Novel Waveguide RF Wien Filter for Electric Dipole Moment Measurements of Protons and Deuterons

    Full text link
    The conventional Wien filter is a device with orthogonal static magnetic and electric fields, often used for velocity separation of charged particles. Here we describe the electromagnetic design calculations for a novel waveguide RF Wien filter that will be employed to solely manipulate the spins of protons or deuterons at frequencies of about 0.1 to 2 MHz at the COoler SYnchrotron COSY at J\"ulich. The device will be used in a future experiment that aims at measuring the proton and deuteron electric dipole moments, which are expected to be very small. Their determination, however, would have a huge impact on our understanding of the universe.Comment: 10 pages, 10 figures, 4 table

    Diversité des méthodes utilisées par les laboratoires français pour la surveillance des infections à cytomégalovirus humain

    Get PDF
    Monitoring cytomegalovirus circulating viral load is an important parameter of the follow-up in immunocompromised patients. It can be measured either by DNAemia or by pp65 antigenemia. The French national reference center for cytomegaloviruses organized an investigation of practice in 37 teacher hospital virology laboratories to assess the situation in France in 2010. Methods A questionnaire was sent to collect following information: method used in routine for monitoring of circulating viral load of CMV, assay used, sample matrix and extraction method. Results Thirty-six over thirty-seven laboratories filled the questionnaire. Among these, 67% used the quantitative PCR in routine, 11% antigenemia and 22% antigenemia or quantitative PCR; 87% of the laboratories use whole blood for quantitative PCR, whereas 10% and 3% use plasma and leukocytes respectively. Among the laboratories using DNAemia, 100% used real-time PCR assays, 91% use an automated extraction and 9% a manual extraction. Conclusion Thus in France, measurement of DNAemia by real-time PCR is a tool, which gradually replaces the antigenemia for the monitoring of cytomegalovirus infection among immunocompromised patients. The very great diversity of the methods used justifies the installation of a national quality control on total blood, matrix used by 87% of the laboratories

    Phase Measurement for Driven Spin Oscillations in a Storage Ring

    Get PDF
    This paper reports the first simultaneous measurement of the horizontal and vertical components of the polarization vector in a storage ring under the influence of a radio frequency (rf) solenoid. The experiments were performed at the Cooler Synchrotron COSY in J\"ulich using a vector polarized, bunched 0.97GeV/c0.97\,\textrm{GeV/c} deuteron beam. Using the new spin feedback system, we set the initial phase difference between the solenoid field and the precession of the polarization vector to a predefined value. The feedback system was then switched off, allowing the phase difference to change over time, and the solenoid was switched on to rotate the polarization vector. We observed an oscillation of the vertical polarization component and the phase difference. The oscillations can be described using an analytical model. The results of this experiment also apply to other rf devices with horizontal magnetic fields, such as Wien filters. The precise manipulation of particle spins in storage rings is a prerequisite for measuring the electric dipole moment (EDM) of charged particles

    Spin tune mapping as a novel tool to probe the spin dynamics in storage rings

    Get PDF
    Precision experiments, such as the search for electric dipole moments of charged particles using storage rings, demand for an understanding of the spin dynamics with unprecedented accuracy. The ultimate aim is to measure the electric dipole moments with a sensitivity up to 15 orders in magnitude better than the magnetic dipole moment of the stored particles. This formidable task requires an understanding of the background to the signal of the electric dipole from rotations of the spins in the spurious magnetic fields of a storage ring. One of the observables, especially sensitive to the imperfection magnetic fields in the ring is the angular orientation of stable spin axis. Up to now, the stable spin axis has never been determined experimentally, and in addition, the JEDI collaboration for the first time succeeded to quantify the background signals that stem from false rotations of the magnetic dipole moments in the horizontal and longitudinal imperfection magnetic fields of the storage ring. To this end, we developed a new method based on the spin tune response of a machine to artificially applied longitudinal magnetic fields. This novel technique, called \textit{spin tune mapping}, emerges as a very powerful tool to probe the spin dynamics in storage rings. The technique was experimentally tested in 2014 at the cooler synchrotron COSY, and for the first time, the angular orientation of the stable spin axis at two different locations in the ring has been determined to an unprecedented accuracy of better than 2.8μ2.8\murad.Comment: 32 pages, 15 figures, 7 table

    Phase locking the spin precession in a storage ring

    Get PDF
    This letter reports the successful use of feedback from a spin polarization measurement to the revolution frequency of a 0.97 GeV/cc bunched and polarized deuteron beam in the Cooler Synchrotron (COSY) storage ring in order to control both the precession rate (121\approx 121 kHz) and the phase of the horizontal polarization component. Real time synchronization with a radio frequency (rf) solenoid made possible the rotation of the polarization out of the horizontal plane, yielding a demonstration of the feedback method to manipulate the polarization. In particular, the rotation rate shows a sinusoidal function of the horizontal polarization phase (relative to the rf solenoid), which was controlled to within a one standard deviation range of σ=0.21\sigma = 0.21 rad. The minimum possible adjustment was 3.7 mHz out of a revolution frequency of 753 kHz, which changes the precession rate by 26 mrad/s. Such a capability meets a requirement for the use of storage rings to look for an intrinsic electric dipole moment of charged particles

    Occurrence and overlap of natural disasters, complex emergencies and epidemics during the past decade (1995–2004)

    Get PDF
    BACKGROUND: The fields of expertise of natural disasters and complex emergencies (CEs) are quite distinct, with different tools for mitigation and response as well as different types of competent organizations and qualified professionals who respond. However, natural disasters and CEs can occur concurrently in the same geographic location, and epidemics can occur during or following either event. The occurrence and overlap of these three types of events have not been well studied. METHODS: All natural disasters, CEs and epidemics occurring within the past decade (1995–2004) that met the inclusion criteria were included. The largest 30 events in each category were based on the total number of deaths recorded. The main databases used were the Emergency Events Database for natural disasters, the Uppsala Conflict Database Program for CEs and the World Health Organization outbreaks archive for epidemics. ANALYSIS: During the past decade, 63% of the largest CEs had ≥1 epidemic compared with 23% of the largest natural disasters. Twenty-seven percent of the largest natural disasters occurred in areas with ≥1 ongoing CE while 87% of the largest CEs had ≥1 natural disaster. CONCLUSION: Epidemics commonly occur during CEs. The data presented in this article do not support the often-repeated assertion that epidemics, especially large-scale epidemics, commonly occur following large-scale natural disasters. This observation has important policy and programmatic implications when preparing and responding to epidemics. There is an important and previously unrecognized overlap between natural disasters and CEs. Training and tools are needed to help bridge the gap between the different type of organizations and professionals who respond to natural disasters and CEs to ensure an integrated and coordinated response

    Are textbook lungs really normal? A cadaveric study on the anatomical and clinical importance of variations in the major lung fissures, and the incomplete right horizontal fissure.

    Get PDF
    INTRODUCTION: The lungs have three main fissures: the right oblique fissure (ROF), right horizontal fissure (RHF), and left oblique fissure (LOF). These can be complete, incomplete or absent; quantifying the degree of completeness of these fissures is novel. Standard textbooks often refer to the fissures as complete, but awareness of variation is essential in thoracic surgery. MATERIALS AND METHODS: Fissures in 81 pairs of cadaveric lungs were classified. Oblique fissures were measured from lung hila posteriorly to the lung hila anteriorly; and the RHF measured from the ROF to the anteromedial lung edge. The degree of completeness of fissures was expressed as a percentage of the total projected length were they to be complete. The frequency and location of accessory fissures was noted. RESULTS: LOF were complete in 66/81 (81.5%), incomplete in 13/81 (16.0%) and absent in 2/81 (2.47%); ROF were complete in 52/81 (64.2%), incomplete in 29/81 (35.8%) and never absent; RHF were more variable, complete in 18/81 (22.2%), incomplete in 54/81 (66.7%) and absent in 9/81 (11.1%). LOF and ROF were on average 97.1% and 91.6% complete, respectively, being deficient posteriorly at the lung hila. The RHF on average 69.4% complete, being deficient anteromedially. There were accessory fissures in 10 left and 19 right lungs. CONCLUSIONS: This study provides a projection of the anatomy thoracic surgeons may encounter at operation, in particular the variable RHF. This knowledge is essential for optimal outcomes in both benign and oncological procedures influenced by the fissures

    Determinants of parents' reticence toward vaccination in urban areas in Benin (West Africa)

    Get PDF
    Analysis of the data reveals those who are vaccination-reticent say it goes against the will of God, that it is a poison from the “white witch doctor,” and a sin. Members of the control group argued against this, but without conviction. They adhere to the principle of obedience to authority, a biblical precept invoked when the vaccinators oblige them to vaccinate their children. To limit the spread of this phenomenon among the religious population of the cities like Parakou and Cotonou in Benin, more detailed information and negotiation between health authorities and pastors of the churches are essential
    corecore