558 research outputs found
Basic kinetic wealth-exchange models: common features and open problems
We review the basic kinetic wealth-exchange models of Angle [J. Angle, Social
Forces 65 (1986) 293; J. Math. Sociol. 26 (2002) 217], Bennati [E. Bennati,
Rivista Internazionale di Scienze Economiche e Commerciali 35 (1988) 735],
Chakraborti and Chakrabarti [A. Chakraborti, B. K. Chakrabarti, Eur. Phys. J. B
17 (2000) 167], and of Dragulescu and Yakovenko [A. Dragulescu, V. M.
Yakovenko, Eur. Phys. J. B 17 (2000) 723]. Analytical fitting forms for the
equilibrium wealth distributions are proposed. The influence of heterogeneity
is investigated, the appearance of the fat tail in the wealth distribution and
the relaxation to equilibrium are discussed. A unified reformulation of the
models considered is suggested.Comment: Updated version; 9 pages, 5 figures, 2 table
Rheolytic Thrombectomy with or without Adjunctive Indwelling Pharmacolysis in Patients Presenting with Acute Pulmonary Embolism Presenting with Right Heart Strain and/or Pulseless Electrical Activity
Purpose. To evaluate the safety and efficacy of the Possis rheolytic thrombectomy with or without indwelling catheter-directed pharmacolysis for the treatment of massive pulmonary embolus in patients presenting with right heart strain and/or a pulseless electrical activity (PEA). Materials and Methods. Retrospective review of patients undergoing pulmonary pharmacolysis was performed (07/2004â06/2009). Pre- and posttreatment Miller index scoring weres calculated and compared. Patients were evaluated for tPA doses, ICU stay, hospital stay, and survival by Kaplan-Meier analysis. Results. 11 patients with massive PE were found, with 10/11 presenting with a Miller score of >17 (range: 16â27, mean: 23.2). CTPA and/or echocardiographic evidence of right heart strain was found in 10/11 patients. 3 (27%) patients presented with a PEA event. Two (18%) patients had a contraindication to pharmacolysis and were treated with mechanical thrombectomy alone. The intraprocedural mortality was 9% (n = 1/11). Of the 10 patients who survived the initial treatment, 7 patients underwent standard mechanical thrombectomy initially, while 5 received power pulse spray mechanical thrombectomy. Eight of these 10 patients underwent adjunctive indwelling catheter-directed thrombolysis. The mean catheter-directed infusion duration was 18 hours (range of 12â26 hours). The average intraprocedural, infusion, and total doses of tPA were 7âmg, 19.7âmg, and 26.7âmg, respectively. There was a 91% (10/11) technical success rate. The failure was the single mortality. Average reduction in Miller score was 9.5 or 41% (P = 0.009), obstructive index of 6.4 or 47% (P = 0.03), and perfusion index of 2.7 or 28% (P = 0.05). Average ICU and hospital stay were 7.4 days (range 2â27 days) and 21.3 days (range 6â60 days), respectively. Intent to treat survival was 90% at 6, 12, and 18 months. Conclusion. Rheolytic thrombectomy with or without adjunctive catheter-directed thrombolysis provides a safe and effective method for treatment of acute PE in patients who present with right heart strain and/or a PEA event
The Tevatron at the Frontier of Dark Matter Direct Detection
Direct detection of dark matter (DM) requires an interaction of dark matter
particles with nucleons. The same interaction can lead to dark matter pair
production at a hadron collider, and with the addition of initial state
radiation this may lead to mono-jet signals. Mono-jet searches at the Tevatron
can thus place limits on DM direct detection rates. We study these bounds both
in the case where there is a contact interaction between DM and the standard
model and where there is a mediator kinematically accessible at the Tevatron.
We find that in many cases the Tevatron provides the current best limit,
particularly for light dark matter, below 5 GeV, and for spin dependent
interactions. Non-standard dark matter candidates are also constrained. The
introduction of a light mediator significantly weakens the collider bound. A
direct detection discovery that is in apparent conflict with mono-jet limits
will thus point to a new light state coupling the standard model to the dark
sector. Mono-jet searches with more luminosity and including the spectrum shape
in the analysis can improve the constraints on DM-nucleon scattering cross
section.Comment: 20 pages, 8 figures, final version in JHE
Allogeneic endometrial regenerative cells: An "Off the shelf solution" for critical limb ischemia?
Critical limb ischemia (CLI) is an advanced form of peripheral artery disease which is responsible for approximately 100,000 amputations per year in the US. Trials to date have reported clinical improvement and reduced need for amputation in CLI patients receiving autologous bone marrow or mobilized peripheral blood stem cells for stimulation of angiogenesis. While such treatments are currently entering Phase III trials, practical and scientific pitfalls will limit widespread implementation if efficacy is proven. Hurdles to be overcome include: a) reduced angiogenic potential of autologous cells in aged patients with cardiovascular risk factors; b) invasiveness/adverse effects of bone marrow extraction and G-CSF mobilization, respectively; and c) need for on-site cellular manipulation. The Endometrial Regenerative Cell (ERC) is a mesenchymal-like stem cell derived from the menstrual blood that is believed to be associated with endometrial angiogenesis. We discuss the possibility of using allogeneic ERCs as an "off the shelf" treatment for CLI based on the following properties: a) High levels of growth factors and matrix metalloprotease production; b) Ability to inhibits inflammatory responses and lack of immunogenicity; and c) Expandability to great quantities without loss of differentiation ability or karyotypic abnormalities
Dark Matter Capture in the First Stars: a Power Source and Limit on Stellar Mass
The annihilation of weakly interacting massive particles can provide an
important heat source for the first (Pop. III) stars, potentially leading to a
new phase of stellar evolution known as a "Dark Star". When dark matter (DM)
capture via scattering off of baryons is included, the luminosity from DM
annihilation may dominate over the luminosity due to fusion, depending on the
DM density and scattering cross-section. The influx of DM due to capture may
thus prolong the lifetime of the Dark Stars. Comparison of DM luminosity with
the Eddington luminosity for the star may constrain the stellar mass of zero
metallicity stars; in this case DM will uniquely determine the mass of the
first stars. Alternatively, if sufficiently massive Pop. III stars are found,
they might be used to bound dark matter properties.Comment: 19 pages, 4 figures, 3 Tables updated captions and graphs, corrected
grammer, and added citations revised for submission to JCA
Phenomenological Aspects of Gauge Mediation with Sequestered Supersymmetry Breaking in light of Dark Matter Detection
In a recent work, a model of gauge mediation with sequestered supersymmetry
(SUSY) breaking was proposed. In this model, the mass of the gravitino is
O(100) GeV without causing the flavor-changing neutral-current problem. In
contrast to traditional gauge mediation, the gravitino is not the lightest SUSY
particle and the neutralino is the candidate of the dark matter. In this paper,
we investigate phenomenological aspects of this model and discuss the
possibility of the direct detection of the dark matter. In particular, we focus
on the light neutralino case and find that the light-Higgsino scenario such as
the focus point is interesting, taking account of the recent CDMS result.Comment: 17 pages, 8 figures; v2:references added, some corrections;
v3:version accepted for publication in JHE
Hierarchies of Susy Splittings and Invisible Photinos as Dark Matter
We explore how to generate hierarchies in the splittings between
superpartners. Some of the consequences are the existence of invisible
components of dark matter, new inflaton candidates, invisible monopoles and a
number of invisible particles that might dominate during various eras, in
particular between BBN and recombination and decay subsequently.Comment: 16 pages. v3: Ref. 27 has been modified. v4: Published versio
Material screening and selection for XENON100
Results of the extensive radioactivity screening campaign to identify
materials for the construction of XENON100 are reported. This Dark Matter
search experiment is operated underground at Laboratori Nazionali del Gran
Sasso (LNGS), Italy. Several ultra sensitive High Purity Germanium detectors
(HPGe) have been used for gamma ray spectrometry. Mass spectrometry has been
applied for a few low mass plastic samples. Detailed tables with the
radioactive contaminations of all screened samples are presented, together with
the implications for XENON100.Comment: 8 pages, 1 figur
Long Lived Fourth Generation and the Higgs
A chiral fourth generation is a simple and well motivated extension of the
standard model, and has important consequences for Higgs phenomenology. Here we
consider a scenario where the fourth generation neutrinos are long lived and
have both a Dirac and Majorana mass term. Such neutrinos can be as light as 40
GeV and can be the dominant decay mode of the Higgs boson for Higgs masses
below the W-boson threshold. We study the effect of the Majorana mass term on
the Higgs branching fractions and reevaluate the Tevatron constraints on the
Higgs mass. We discuss the prospects for the LHC to detect the semi-invisible
Higgs decays into fourth generation neutrino pairs. Under the assumption that
the lightest fourth generation neutrino is stable, it's thermal relic density
can be up to 20% of the observed dark matter density in the universe. This is
in agreement with current constraints on the spin dependent neutrino-neutron
cross section, but can be probed by the next generation of dark matter direct
detection experiments.Comment: v1: 19 pages, 5 figures; v2: References added; v3: version to appear
in JHE
The XENON100 Dark Matter Experiment
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time
projection chamber (TPC) to search for Xe nuclear recoils resulting from the
scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this
paper we present a detailed description of the detector design and present
performance results, as established during the commissioning phase and during
the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe
veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating
inside the liquid or in Xe gas. The LXe target and veto are contained in a
low-radioactivity stainless steel vessel, embedded in a passive radiation
shield. The experiment is installed underground at the Laboratori Nazionali del
Gran Sasso (LNGS), Italy and has recently published results from a 100
live-days dark matter search. The ultimate design goal of XENON100 is to
achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of
\sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.Comment: 23 pages, 27 figures; version accepted by journa
- âŠ