287 research outputs found

    Real-world gait speed estimation, frailty and handgrip strength: a cohort-based study.

    Get PDF
    Gait speed is a reliable outcome measure across multiple diagnoses, recognized as the 6th vital sign. The focus of the present study was on assessment of gait speed in long-term real-life settings with the aim to: (1) demonstrate feasibility in large cohort studies, using data recorded with a wrist-worn accelerometer device; (2) investigate whether the walking speed assessed in the real-world is consistent with expected trends, and associated with clinical scores such as frailty/handgrip strength. This cross-sectional study included n = 2809 participants (1508 women, 1301 men, [45-75] years old), monitored with a wrist-worn device for 13 consecutive days. Validated algorithms were used to detect the gait bouts and estimate speed. A set of metrics were derived from the statistical distribution of speed of gait bouts categorized by duration (short, medium, long). The estimated usual gait speed (1-1.6 m/s) appears consistent with normative values and expected trends with age, gender, BMI and physical activity levels. Speed metrics significantly improved detection of frailty: AUC increase from 0.763 (no speed metrics) to 0.798, 0.800 and 0.793 for the 95th percentile of individual's gait speed for bout durations < 30, 30-120 and > 120 s, respectively (all p < 0.001). Similarly, speed metrics also improved the prediction of handgrip strength: AUC increase from 0.669 (no speed metrics) to 0.696, 0.696 and 0.691 for the 95th percentile of individual's gait speed for bout durations < 30, 30-120 and > 120 s, respectively (all p < 0.001). Forward stepwise regression showed that the 95th percentile speed of gait bouts with medium duration (30-120 s) to be the best predictor for both conditions. The study provides evidence that real-world gait speed can be estimated using a wrist-worn wearable system, and can be used as reliable indicator of age-related functional decline

    Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease

    Get PDF
    Accurate assessment of Parkinson’s disease (PD) ON and OFF states in the usual environment is essential for tailoring optimal treatments. Wearables facilitate measurements of gait in novel and unsupervised environments; however, differences between unsupervised and in-laboratory measures have been reported in PD. We aimed to investigate whether unsupervised gait speed discriminates medication states and which supervised tests most accurately represent home perfor-mance. In-lab gait speeds from different gait tasks were compared to home speeds of 27 PD patients at ON and OFF states using inertial sensors. Daily gait speed distribution was expressed in percentiles and walking bout (WB) length. Gait speeds differentiated ON and OFF states in the lab and the home. When comparing lab with home performance, ON assessments in the lab showed moderate-to-high correlations with faster gait speeds in unsupervised environment (r = 0.69; p < 0.001), associated with long WB. OFF gait assessments in the lab showed moderate correlation values with slow gait speeds during OFF state at home (r = 0.56; p = 0.004), associated with short WB. In-lab and daily assessments of gait speed with wearables capture additional integrative aspects of PD, reflecting different aspects of mobility. Unsupervised assessment using wearables adds complementary information to the clinical assessment of motor fluctuations in PD.This research was funded by Keep Control from the EU’s Horizon 2020 (H2020) research and innovation program under the Marie Sklodowska-Curie (MSCA-ITN-ETN), grant number 721577. No other financial support and funding for the preceding twelve months are applied

    Metabolic Effects Of Duodenojejunal Bypass Surgery In A Rat Model Of Type 1 Diabetes

    Get PDF
    Background Metabolic surgery has beneficial metabolic effects, including remission of type 2 diabetes. We hypothesized that duodenojejunal bypass (DJB) surgery can protect against development of type 1 diabetes (T1D) by enhancing regulation of cellular and molecular pathways that control glucose homeostasis. Methods BBDP/Wor rats, which are prone to develop spontaneous autoimmune T1D, underwent loop DJB (n = 15) or sham (n = 15) surgery at a median age of 41 days, before development of diabetes. At T1D diagnosis, a subcutaneous insulin pellet was implanted, oral glucose tolerance test was performed 21 days later, and tissues were collected 25 days after onset of T1D. Pancreas and liver tissues were assessed by histology and RT-qPCR. Fecal microbiota composition was analyzed by 16S V4 sequencing. Results Postoperatively, DJB rats weighed less than sham rats (287.8 vs 329.9 g,P = 0.04). In both groups, 14 of 15 rats developed T1D, at similar age of onset (87 days in DJB vs 81 days in sham,P = 0.17). There was no difference in oral glucose tolerance, fasting and stimulated plasma insulin and c-peptide levels, and immunohistochemical analysis of insulin-positive cells in the pancreas. DJB rats needed 1.3 +/- 0.4 insulin implants vs 1.9 +/- 0.5 in sham rats (P = 0.002). Fasting and glucose stimulated glucagon-like peptide 1 (GLP-1) secretion was elevated after DJB surgery. DJB rats had reduced markers of metabolic stress in liver. After DJB, the fecal microbiome changed significantly, including increases inAkkermansiaandRuminococcus, while the changes were minimal in sham rats. Conclusion DJB does not protect against autoimmune T1D in BBDP/Wor rats, but reduces the need for exogenous insulin and facilitates other metabolic benefits including weight loss, increased GLP-1 secretion, reduced hepatic stress, and altered gut microbiome

    Design and test of a MEMS strain-sensing device for monitoring artificial knee implants

    Get PDF
    This paper describes the development of a polyimide-based MEMS strain-sensing device. Finite element analysis was used to investigate an artificial knee implant and assist on device design and to optimize sensing characteristics. The sensing element of the device was fabricated using polyimide micromachining with embedded thin-metallic wires and placed into a knee prosthesis. The device was evaluated experimentally in a mechanical knee simulator using static and dynamic axial load conditions similar to those encountered in vivo. Results indicates the sensor is capable of measuring the strain associated to the total axial forces in the range of approximately 4 times body weight with a good sensitivity and accuracy for events happening within 1 s time windo

    The relationship between video display terminals (VDTs) usage and dermatologic manifestations : a cross sectional study

    Get PDF
    BACKGROUND: Recently, it has been observed that Video Display Terminals (VDTs) usage for long periods can cause some dermatological manifestations on the face. An analytical cross-sectional study was designed in order to determine this relationship. METHODS: In this study, 600 office workers were chosen randomly from an organization in Tehran (Iran). The subjects were then divided into two groups based on their exposure to VDTs. 306 workers were considered exposure negative (non VDT user) who worked less than 7 hours a week with VDTs. The remainders 294 were exposure-positive, who worked 7 hours or more with VDTs. The frequency of dermatologic manifestations was compared in these two groups. RESULTS: In the exposure-positive and exposure-negative groups, the frequency of these dermatologic manifestations were 27 and 5 respectively. After statistical analysis, a P.value of < 0.05 was obtained indicating a statistically significant difference between these two groups for dermatological manifestations. CONCLUSION: According to our study, there is a relationship between dermatologic manifestations on the face and exposure to VDTs

    Applications of the PowerGlove

    Get PDF
    The hand is important in many daily life activities. During aging, quality of fine motor control of hand and fingers is decreasing. Also motor symptoms of the hand are important to define for instance the neurological state of a Parkinson’s disease patient. Although objective and reliable measurement of hand and finger dynamics is of interest, current measurement systems are limited. This paper describes the application of the PowerGlove, a new measurement system based on miniature inertial and magnetic sensors, to study the finger interdependency in healthy elderly and objectively quantify hand motor symptoms in Parkinson’s disease. Results of pilot experiments in young healthy subjects are shown to evaluate the feasibility of the applications

    Cognitive loading affects motor awareness and movement kinematics but not locomotor trajectories during goal-directed walking in a virtual reality environment.

    Get PDF
    The primary purpose of this study was to investigate the effects of cognitive loading on movement kinematics and trajectory formation during goal-directed walking in a virtual reality (VR) environment. The secondary objective was to measure how participants corrected their trajectories for perturbed feedback and how participants' awareness of such perturbations changed under cognitive loading. We asked 14 healthy young adults to walk towards four different target locations in a VR environment while their movements were tracked and played back in real-time on a large projection screen. In 75% of all trials we introduced angular deviations of ±5° to ±30° between the veridical walking trajectory and the visual feedback. Participants performed a second experimental block under cognitive load (serial-7 subtraction, counter-balanced across participants). We measured walking kinematics (joint-angles, velocity profiles) and motor performance (end-point-compensation, trajectory-deviations). Motor awareness was determined by asking participants to rate the veracity of the feedback after every trial. In-line with previous findings in natural settings, participants displayed stereotypical walking trajectories in a VR environment. Our results extend these findings as they demonstrate that taxing cognitive resources did not affect trajectory formation and deviations although it interfered with the participants' movement kinematics, in particular walking velocity. Additionally, we report that motor awareness was selectively impaired by the secondary task in trials with high perceptual uncertainty. Compared with data on eye and arm movements our findings lend support to the hypothesis that the central nervous system (CNS) uses common mechanisms to govern goal-directed movements, including locomotion. We discuss our results with respect to the use of VR methods in gait control and rehabilitation

    Razine antinuklearnoga antitijela i reumatoidnoga faktora u radnika izloženih silicijevu dioksidu

    Get PDF
    A lot of workers in industries such as foundry, stonecutting, and sandblasting are exposed to higher than permissible levels of crystalline silica. Various alterations in humoral immune function have been reported in silicosis patients and workers exposed to silica dust. The aim of this study was to measure antinuclear antibody (ANA) and rheumatoid factor (RF) levels in foundry workers exposed to silica and to compare them with a control group without such exposure. ANA and RF were measured in 78 exposed and 73 non-exposed workers, and standard statistical methods were used to compare them. The two groups did not significantly differ in age and smoking. Mean work duration of the exposed and non-exposed workers was (14.9±4.72) years and (12.41±6.3) years, respectively. Ten exposed workers had silicosis. ANA was negative in all workers in either group. Its mean titer did not differ significantly between the exposed and control workers [(0.39±0.15) IU mL-1 vs. (0.36±0.17) IU mL-1, respectively]. RF was positive in two workers of each group. Other studies have reported an increase in ANA and RF associated with exposure to silica dust and silicosis. In contrast, our study suggests that exposure to silica dust does not increase the level of ANA and RF in exposed workers.Mnogi su radnici izloženi kristalnomu silicijevu dioksidu u razinama iznad dopuštenih. U oboljelih od silikoze i radnika izloženih prašinama koje sadržavaju silicijev dioksid zamijećen je niz oštećenja humoralne obrane. Budući da su radnici u ljevaonicama izloženi visokim razinama kristalnoga silicijeva dioksida, u njih bismo očekivali ovakve humoralne poremećaje. Cilj je ovog ispitivanja bio izmjeriti i usporediti razine antinuklearnih protutijela (ANA) i reumatoidnoga faktora (RF) u krvi radnika u ljevaonici izloženih silicijevu dioksidu i neizložene kontrolne skupine. ANA i RF izmjereni su u 78 izloženih radnika i 73 neizložena radnika te su uspoređeni s pomoću standardnih statističkih metoda. Dvije se skupine nisu bitno razlikovale u broju pušača i u dobi. Prosječna duljina radnog vijeka izloženih radnika bila je (14,9±4,72) godine, a neizloženih (12,41±6,3) godine. Deset izloženih radnika imalo je silikozu. Nalazi ANA bili su negativni u obje skupine radnika. Srednja vrijednost titra ANA iznosila je (0,39±0,15) IU mL-1 u izloženih ispitanika, a (0,36±0,17) IU mL-1 u kontrola, što je statistički zanemariva razlika. Nalaz RF-a bio je pozitivan u dva izložena te dva kontrolna radnika. Naše ispitivanje upućuje na to da prašine silicijeva dioksida ne uzrokuju porast razina ANA i RF-a u izloženih radnika

    Patients with clinically metabolically healthy obesity are not necessarily healthy subclinically: further support for bariatric surgery in patients without metabolic disease?

    Get PDF
    Background: Nonalcoholic fatty liver disease (NAFLD) increases the risk of liver cirrhosis and hepatocellular carcinoma and is also strongly correlated with extrahepatic diseases, including cardiovascular disease and type 2 diabetes. This risk of NAFLD among obese individuals who are otherwise metabolically healthy is not well characterized. Objectives: To determine the prevalence and characteristics of NAFLD in individuals with metabolically healthy obesity. Setting: A tertiary, academic, referral hospital. Methods: All patients who underwent bariatric surgery with intraoperative liver biopsy from 2008 to 2015 were identified. Patients with preoperative hypertension, dyslipidemia, or prediabetes/diabetes were excluded to identify a cohort of metabolically healthy obesity patients. Liver biopsy reports were reviewed to determine the prevalence of NAFLD. Results: A total of 270 patients (7.0% of the total bariatric surgery patients) met the strict inclusion criteria for metabolically healthy obesity. The average age was 38 ± 10 years and the average body mass index was 47 ± 7 kg/m2. Abnormal alanine aminotransferase (>45 U/L) and asparate aminotransferase levels (>40 U/L) were observed in 28 (10.4%) and 18 (6.7%) patients, respectively. A total of 96 (35.5%) patients had NAFLD with NALFD Activity Scores 0 to 2 (n = 61), 3 to 4 (n = 25), and 5 to 8 (n = 10). A total of 62 (23%) patients had lobular inflammation, 23 (8.5%) had hepatocyte ballooning, 22 (8.2%) had steatohepatitis, and 12 (4.4%) had liver fibrosis. Conclusion: Even with the use of strict criteria to eliminate all patients with any metabolic problems, a significant proportion of metabolically healthy patients had unsuspected NAFLD. The need and clinical utility of routine screening of obese patients for fatty liver disease and the role of bariatric surgery in the management of NAFLD warrants further investigation
    corecore