33 research outputs found

    Gadolinium-enhanced magnetic resonance angiography for hepatomesenteric vascular evaluation: single and double doses comparison in schistosomiasis patients

    Get PDF
    OBJECTIVE: To evaluate the visibility of hepatomesenteric vascular segments by 3D gadolinium-enhanced magnetic resonance (MR) angiography and to compare the method effectiveness between two different gadolinium doses (single and double doses). MATERIALS AND METHODS: A prospective study was performed with 36 schistosomiasis patients who were submitted to 3D contrast-enhanced MR angiography. Scans were performed in a high-field equipment (1.5 T), with body coil and power injector for intravenous contrast administration. Contrast double doses (Gd-DTPA 0.2 mmol/kg) and single doses (0.1 mmol/kg) were randomly used respectively in 21 and 15 patients. Studies were interpreted by consensus between two observers who have rated the visualization degree of 25 proximal vascular segments without knowing the dose used. RESULTS: Proximal and calibrous vascular segments have presented higher visualization degree in the greatest part of the sample studied. The celiac trunk, common hepatic artery, splenic artery, proximal and medium third of superior mesenteric artery, portal vein, splenic vein and superior mesenteric vein have presented grade 2 visualization in more than 70% of the sample studied. As regards comparison between different doses, there was no significant difference (p < 0.05) in the visualization degree of several structures evaluated, between double dose and single dose groups, except for an isolate case of evaluation of right hepatic artery (p = 0.008) in which the single dose group has presented a higher frequency of grade 2 visualization with statistical significance. CONCLUSION: The visualization degree of hepatomesenteric vascular segments by 3D gadolinium-enhanced MR angiography is high, especially in the proximal and calibrous segments. The comparison between groups using single and double contrast doses has demonstrated similar results.OBJETIVO: Determinar a freqüência de visualização dos segmentos da circulação hepatomesentérica pela angiografia por ressonância magnética (angio-RM) com contraste e comparar o valor do método, utilizando-se duas diferentes dosagens de gadolínio (doses simples e dupla). MATERIAIS E MÉTODOS: Estudo prospectivo de 36 pacientes esquistossomóticos submetidos a angio-RM. Os exames foram realizados em equipamento de RM de 1,5 T, usando-se bobina de corpo e bomba injetora para a administração endovenosa do contraste. Foram utilizadas, de maneira randomizada, dose dupla do contraste paramagnético (0,2 mmol/kg de Gd-DTPA) em 21 pacientes e dose simples (0,1 mmol/kg) em outros 15 pacientes. Os exames foram interpretados por dois observadores em consenso, que classificaram o grau de visualização de 25 segmentos vasculares estabelecidos para análise, sem conhecimento da dose de gadolínio utilizada. RESULTADOS: Os segmentos vasculares proximais e de maior calibre foram as estruturas com melhor grau de visualização na maioria da amostra em estudo. O tronco celíaco, a artéria hepática comum, a artéria esplênica, a croça e terço médio da artéria mesentérica superior, a veia porta, a veia esplênica e a veia mesentérica superior apresentaram grau 2 de visualização em mais de 70% da amostra. Quanto à comparação das diferentes dosagens, não houve diferença significante (p < 0,05) no grau de visualização das diversas estruturas analisadas entre os grupos dose simples e dose dupla, com uma exceção isolada: na avaliação da artéria hepática direita (p = 0,008), o grupo dose simples apresentou maior freqüência de visualização grau 2, com valor significante. CONCLUSÃO: O grau de visualização dos segmentos vasculares hepatomesentéricos pela angio-RM com contraste é elevado, sendo maior nos segmentos proximais e de maior calibre. A comparação entre os grupos que utilizaram dose simples e dupla de contraste demonstrou resultados semelhantes.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de Diagnóstico por ImagemUNIFESP, EPM, Depto. de Diagnóstico por ImagemSciEL

    Interobserver variability of ultrasound parameters in portal hypertension

    Get PDF
    The aim of this study was to assess interobserver agreement of ultrasound parameters for portal hypertension in hepatosplenic mansonic schistosomiasis. Spleen size, diameter of the portal, splenic and superior mesenteric veins and presence of thrombosis and cavernous transformation were determined by three radiologists in blinded and independent fashion in 30 patients. Interobserver agreement was measured by the kappa index and intraclass correlation coefficient. Interobserver agreement was considered substantial (κ = 0.714-0.795) for portal vein thrombosis and perfect (κ = 1) for cavernous transformation. Interobserver agreement measured by the intraclass correlation coefficient was excellent for longitudinal diameter of the spleen (r = 0.828-0.869) and splenic index (r = 0.816-0.905) and varied from fair to almost perfect for diameter of the portal (r = 0.622-0.675), splenic (r = 0.573-0.913) and superior mesenteric (r = 0.525-0.607) veins. According to the results, ultrasound is a highly reproducible method for the main morphological parameters of portal hypertension in schistosomiasis patients.Universidade Federal de São Paulo (UNIFESP) Departamento de Diagnóstico por ImagensUniversidade de Brasília Faculdade de MedicinaUNIFESP, Depto. de Diagnóstico por ImagensSciEL

    Validation of ultrasound examination for assessment of the abdominal visceral fat in clinically serious obese patient

    Get PDF
    RACIONAL: A tomografia computadorizada é o padrão-ouro para a medida da gordura abdominal visceral. No entanto é dispendiosa e envolve submeter os doentes à radiação ionizante. OBJETIVO: Validar o método ultrassonográfico para avaliação da gordura abdominal visceral em obesos clinicamente graves de ambos os sexos. MÉTODOS: A amostra incluiu adultos com obesidade clinicamente grave que apresentavam índice de massa corporal de 40kg/m² ou entre 35kg/m² e 40kg/m² com comorbidades associadas. Os exames realizados para medição da espessura da gordura visceral foram: ultrassonografia e de tomografia computadorizada. Foram realizados dois exames para avaliação da reprodutibilidade interobservador em uma subamostra de pacientes. O estudo ultrassonográfico foi validado comparando-o aos resultados do exame tomográfico. RESULTADOS: Participaram do estudo 13 pacientes, sendo 61,54% mulheres com IMC médio de 38,82kg/m². A validação foi feita pelo coeficiente de correlação de Pearson resultando ser igual a 0,94 (p = 0,0005). Evidenciou-se correlação positiva e forte entre as duas medidas. Quanto aos resultados da reprodutibilidade, o coeficiente de correlação intraclasse interobservador foi igual a 0,822 com intervalo de confiança de 95% (-0,076 a 0,980), o que revela boa concordância interobservador. A diferença média entre os dois observadores na ultrassonografia foi igual a 0,10 ± 1,51 (p = 0,8898), não significativa e sem viés significativo interobservador. CONCLUSÃO: Foi efetiva a validação do exame ultrassonográfico como substituição ao tomográfico para avaliar a gordura abdominal visceral entre obesos clinicamente graves. A medida ultrassonográfica independe do examinador.BACKGROUND: Computerized tomography is the gold-standard for measurement of abdominal visceral fat. However, it is costly and involves submitting patients to ionizing radiation. AIM: To validate the use of ultrasonography in assessing abdominal visceral fat among clinically serious obese patients of both genders. METHODS: The sample included adult patients with clinically serious obesity with body mass index of 40kg/m2 or from 35kg/m2 to 40kg/m2 with co-morbidities. Abdominal visceral fat thickness was measured using ultrasound and tomography. Two ultrasonographic exams were conducted to assess the interobserver reproducibility among a patient subsample. Validation was done by comparing these results with the tomographic findings. RESULTS: The study included 13 patients (61.54% female) with an average BMI of 38.82 kg/m2. In terms of validation, the result obtained from applying the Pearson correlation coefficient was equal to 0.94 (p = 0.0005), showing a strong positive correlation between the two measurements. As for the results for reproducibility, the interobserver was equal to 0.822, with a confidence interval of 95% (-0.076 to 0.980), revealing good interobserver agreement. The average difference between the two ultrasound interobserver examination was equal to 0.10 ± 1.51 (p=0.8898) and so not significant. Interobserver bias was also not significant. CONCLUSION: The validation of ultrasonographic examination to replace tomographic method in assessing abdominal visceral fat among clinically serious obese patients was effective. The ultrasound measurement is independent of the examiner

    O valor da espessura cortical renal em predizer a função renal em pacientes renais crônicos

    Get PDF
    Objetivo: determinar se existe relação linear entre a espessura do córtex renal, comprimento bipolar e a espessura do parênquima renal em pacientes com insuficiência renal crônica que apresentam diferentes taxas de filtração glomerular (TFGs) e avaliar a reprodutibilidade dessas medidas. Materiais e métodos: exames ultrassonográficos foram realizados em 54 pacientes com insuficiência renal crônica, por dois radiologistas, de modo independente e duplo-cego. A estimativa da TFG foi calculada pela equação de Cockcroft-Gault. A concordância interobservador e o coeficiente de correlação linear (r) foram calculados para estabelecer se existe relação entre medidas renais e a TFG. Resultados: a espessura do córtex renal apresentou moderada correlação com a TFG (r = 0,478; p < 0,001). O comprimento bipolar e a espessura do parênquima apresentaram fraca correlação, com valores de r = 0,380 (p = 0,004) e r = 0,277 (p = 0,116), respectivamente. A concordância interobservador foi excelente para a espessura cortical (0,754) e comprimento bipolar (0,833) e satisfatória para a espessura do parênquima (0,523). Conclusão: a reprodutibilidade das medidas obtidas entre os radiologistas foi boa. A relação entre a TFG estimada com a espessura do córtex renal apresentou moderada correlação e o comprimento bipolar e a espessura do parênquima renal apresentaram fraca correlação.Objective: to determine the presence of linear relationship between renal cortical thickness, bipolar length, and parenchymal thickness in chronic kidney disease patients presenting with different estimated glomerular filtration rates (GFRs) and to assess the reproducibility of these measurements using ultrasonography. Materials and methods: ultrasonography was performed in 54 chronic renal failure patients. The scans were performed by two independent and blinded radiologists. The estimated GFR was calculated using the Cockcroft-Gault equation. Interobserver agreement was calculated and a linear correlation coefficient (r) was determined in order to establish the relationship between the different renal measurements and estimated GFR. Results: the correlation between GFR and measurements of renal cortical thickness, bipolar length, and parenchymal thickness was, respectively, moderate (r = 0.478; p < 0.001), poor (r = 0.380; p = 0.004), and poor (r = 0.277; p = 0.116). The interobserver agreement was considered excellent (0.754) for measurements of cortical thickness and bipolar length (0.833), and satisfactory for parenchymal thickness (0.523). Conclusion: the interobserver reproducibility for renal measurements obtained was good. A moderate correlation was observed between estimated GFR and cortical thickness, but bipolar length and parenchymal thickness were poorly correlated

    Pervasive gaps in Amazonian ecological research

    Get PDF
    Biodiversity loss is one of the main challenges of our time,1,2 and attempts to address it require a clear un derstanding of how ecological communities respond to environmental change across time and space.3,4 While the increasing availability of global databases on ecological communities has advanced our knowledge of biodiversity sensitivity to environmental changes,5–7 vast areas of the tropics remain understudied.8–11 In the American tropics, Amazonia stands out as the world’s most diverse rainforest and the primary source of Neotropical biodiversity,12 but it remains among the least known forests in America and is often underrepre sented in biodiversity databases.13–15 To worsen this situation, human-induced modifications16,17 may elim inate pieces of the Amazon’s biodiversity puzzle before we can use them to understand how ecological com munities are responding. To increase generalization and applicability of biodiversity knowledge,18,19 it is thus crucial to reduce biases in ecological research, particularly in regions projected to face the most pronounced environmental changes. We integrate ecological community metadata of 7,694 sampling sites for multiple or ganism groups in a machine learning model framework to map the research probability across the Brazilian Amazonia, while identifying the region’s vulnerability to environmental change. 15%–18% of the most ne glected areas in ecological research are expected to experience severe climate or land use changes by 2050. This means that unless we take immediate action, we will not be able to establish their current status, much less monitor how it is changing and what is being lostinfo:eu-repo/semantics/publishedVersio

    Pervasive gaps in Amazonian ecological research

    Get PDF

    Pervasive gaps in Amazonian ecological research

    Get PDF
    Biodiversity loss is one of the main challenges of our time,1,2 and attempts to address it require a clear understanding of how ecological communities respond to environmental change across time and space.3,4 While the increasing availability of global databases on ecological communities has advanced our knowledge of biodiversity sensitivity to environmental changes,5,6,7 vast areas of the tropics remain understudied.8,9,10,11 In the American tropics, Amazonia stands out as the world's most diverse rainforest and the primary source of Neotropical biodiversity,12 but it remains among the least known forests in America and is often underrepresented in biodiversity databases.13,14,15 To worsen this situation, human-induced modifications16,17 may eliminate pieces of the Amazon's biodiversity puzzle before we can use them to understand how ecological communities are responding. To increase generalization and applicability of biodiversity knowledge,18,19 it is thus crucial to reduce biases in ecological research, particularly in regions projected to face the most pronounced environmental changes. We integrate ecological community metadata of 7,694 sampling sites for multiple organism groups in a machine learning model framework to map the research probability across the Brazilian Amazonia, while identifying the region's vulnerability to environmental change. 15%–18% of the most neglected areas in ecological research are expected to experience severe climate or land use changes by 2050. This means that unless we take immediate action, we will not be able to establish their current status, much less monitor how it is changing and what is being lost
    corecore