14 research outputs found

    Antibody dynamics and spontaneous viral clearance in patients with acute hepatitis C infection in Rio de Janeiro, Brazil

    Get PDF
    Submitted by Sandra Infurna ([email protected]) on 2017-01-18T10:31:05Z No. of bitstreams: 1 clara_yoshida_etal_IOC_2011.pdf: 146042 bytes, checksum: 8ec889224534b76d755828a99d0660c2 (MD5)Approved for entry into archive by Sandra Infurna ([email protected]) on 2017-01-18T10:59:52Z (GMT) No. of bitstreams: 1 clara_yoshida_etal_IOC_2011.pdf: 146042 bytes, checksum: 8ec889224534b76d755828a99d0660c2 (MD5)Made available in DSpace on 2017-01-18T10:59:52Z (GMT). No. of bitstreams: 1 clara_yoshida_etal_IOC_2011.pdf: 146042 bytes, checksum: 8ec889224534b76d755828a99d0660c2 (MD5) Previous issue date: 2011Innsbruck Medical University. Department of Medical Statistics, Informatics and Health Economics. Innsbruck, Austria.Harvard Medical School. Boston, MA, USA / Massachussets General Hospital. Division of Infectious Diseases. Boston, MA, USA.Harvard Medical School. Boston, MA, USA / Massachussets General Hospital. Gastrointestinal Unit. Boston, MA, USA.Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil.Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil.Laboratório Central de Saúde Pública Noel Nutels. Divisão de Hepatites. Rio de Janeiro, RJ, Brasil.Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil.Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil / Universidade Federal do Estado do Rio de Janeiro. Hospital Universitário Gaffrée Guinle. Unidade de Hepatologia. Rio de Janeiro, RJ, Brasil.Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Desenvolvimento Tecnológico em Virologia. Rio de Janeiro, RJ, Brasil.Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil.Universitätsklinikum Eppendorf. Medizinische Klinik I. Hamburg, Germany.Fondation Merieux. Emerging Pathogens Laboratory. Lyon, France.University of Innsbruck. Institute of Statistics. Innsbruck, Austria.National Institute on Aging. Gerontology Research Center. Baltimore, USA.Innsbruck Medical University. Department of Medical Statistics, Informatics and Health Economics. Innsbruck, Austria.Innsbruck Medical University. Department of Medical Statistics, Informatics and Health Economics. Innsbruck, Austria.Innsbruck Medical University. Department of Medical Statistics, Informatics and Health Economics. Innsbruck, Austria.Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil.Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Hepatites Virais. Rio de Janeiro, RJ. Brasil.Background: The anti-HCV antibody response has not been well characterized during the early phase of HCV infection and little is known about its relationship to the clinical course during this period. Methods: We analyzed serial anti-HCV antibodies longitudinally obtained from a prospective cohort of 65 patients with acute HCV infection by using a microparticle enzyme immunoassay AxSYM HCV 3.0 (Abbott Diagnostics) during the first 12 months from HCV acquisition in Rio de Janeiro, Brazil. Spontaneous viral clearance (SVC) was defined as undetectable HCV RNA in serum, in the absence of treatment, for three consecutive HCV PCR tests within 12-months of follow-up. Results: Baseline antibody values were similar among patient groups with self-limiting HCV evolution (n = 34) and persistent viremia (n = 31) [median (interquartile range) signal/cut-off ratio (s/co) 78.7 (60.7-93.8) vs. 93.9 (67.8- 111.9), p = 0.26]. During 12-months follow-up, patients with acute spontaneous resolving HCV infection showed significantly lower serial antibody response in comparison to individuals progressing to chronic infection [median (interquartile range) s/co 62.7 (35.2-85.0) vs. 98.4 (70.4-127.4), p < 0.0001]. In addition, patients with self-limiting HCV evolution exhibited an expeditious, sharp decline of serial antibody values after SVC in comparison to those measured before SVC [median (interquartile range) s/co 56.0 (25.4-79.3) vs. 79.4 (66.3-103.0), p < 0.0001]. Conclusion: Our findings indicate a rapid short-term decline of antibody values in patients with acute spontaneous resolving HCV infection

    Role of complement and antibodies in controlling infection with pathogenic simian immunodeficiency virus (SIV) in macaques vaccinated with replication-deficient viral vectors

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We investigated the interplay between complement and antibodies upon priming with single-cycle replicating viral vectors (SCIV) encoding SIV antigens combined with Adeno5-SIV or SCIV pseudotyped with murine leukemia virus envelope boosting strategies. The vaccine was applied via spray-immunization to the tonsils of rhesus macaques and compared with systemic regimens.</p> <p>Results</p> <p>Independent of the application regimen or route, viral loads were significantly reduced after challenge with SIVmac239 (p < 0.03) compared to controls. Considerable amounts of neutralizing antibodies were induced in systemic immunized monkeys. Most of the sera harvested during peak viremia exhibited a trend with an inverse correlation between complement C3-deposition on viral particles and plasma viral load within the different vaccination groups. In contrast, the amount of the observed complement-mediated lysis did not correlate with the reduction of SIV titres.</p> <p>Conclusion</p> <p>The heterologous prime-boost strategy with replication-deficient viral vectors administered exclusively via the tonsils did not induce any neutralizing antibodies before challenge. However, after challenge, comparable SIV-specific humoral immune responses were observed in all vaccinated animals. Immunization with single cycle immunodeficiency viruses mounts humoral immune responses comparable to live-attenuated immunodeficiency virus vaccines.</p

    Normal kidney size and its influencing factors - a 64-slice MDCT study of 1.040 asymptomatic patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Normal ultrasound values for pole-to-pole kidney length (LPP) are well established for children, but very little is known about normal kidney size and its influencing factors in adults. The objectives of this study were thus to establish normal CT values for kidney dimensions from a group of unselected patients, identify potential influencing factors, and to estimate their significance.</p> <p>Methods</p> <p>In multiphase thin-slice MDCTs of 2.068 kidneys in 1.040 adults, the kidney length pole to pole (LPP), parenchymal (PW) and cortical width (CW), position and rotation status of the kidneys, number of renal arteries, pyelon width and possible influencing factors that can be visualized, were recorded from a volume data set. For length measurements, axes were adjusted individually in double oblique planes using a 3D-software. Analyses of distribution, T-tests, ANOVA, correlation and multivariate regression analyses were performed.</p> <p>Results</p> <p>LPP was 108.5 ± 12.2 mm for the right, and 111.3 ± 12.6 mm for the left kidney (p < 0.0001 each). PW on the right side was 15.4 ± 2.8 mm, slightly less than 15.9 ± 2.7 mm on the left side (p < 0.0001), the CW was the same (6.6 ± 1.9 mm). The most significant independent predictors for LPP, CW, and PW were body size, BMI, age, and gender (p < 0.001 each). In men, the LPP increases up to the fifth decade of life (p < 0.01). It is also influenced by the position of the kidneys, stenoses and number of renal arteries (SRA/NRA), infarctions suffered, parapelvic cysts, and absence of the contralateral kidney; CW is influenced by age, position, parapelvic cysts, NRA and SRA, and the PW is influenced in addition by rotation status (p < 0.05 each). Depending on the most important factors, gender-specific normal values were indicated for these dimensions, the length and width in cross section, width of the renal pelvis, and parenchyma-renal pyelon ratio.</p> <p>Conclusions</p> <p>Due to the complex influences on kidney size, assessment should be made individually. The most important influencing factors are BMI, height, gender, age, position of the kidneys, stenoses and number of renal arteries.</p

    Comparing penalized splines and fractional polynomials for flexible modelling of the effects of continuous predictor variables

    No full text
    P(enalized)-splines and fractional polynomials (FPs) have emerged as powerful smoothing techniques with increasing popularity in applied research. Both approaches provide considerable flexibility, but only limited comparative evaluations of the performance and properties of the two methods have been conducted to date. Extensive simulations are performed to compare FPs of degree 2 (FP2) and degree 4 (FP4) and two variants of P-splines that used generalized cross validation (GCV) and restricted maximum likelihood (REML) for smoothing parameter selection. The ability of P-splines and FPs to recover the "true" functional form of the association between continuous, binary and survival outcomes and exposure for linear, quadratic and more complex, non-linear functions, using different sample sizes and signal to noise ratios is evaluated. For more curved functions FP2, the current default setting in implementations for fitting FPs in R, STATA and SAS, showed considerable bias and consistently higher mean squared error (MSE) compared to spline-based estimators and FP4, that performed equally well in most simulation settings. FPs however, are prone to artefacts due to the specific choice of the origin, while P-splines based on GCV reveal sometimes wiggly estimates in particular for small sample sizes. Application to a real dataset illustrates the different features of the two approaches.Generalized additive models Simulation study Smoothing

    Elevated γ-glutamyltransferase in implantable cardioverter defibrillator patients

    Full text link
    BACKGROUND: Elevated γ-glutamyltransferase (GGT) is a new risk factor for cardiovascular diseases, but its impact on ventricular tachyarrhythmia occurrence and survival in patients with an implantable cardioverter defibrillator (ICD) is unknown. METHODS AND RESULTS: Considering that GGT levels are gender-dependent, female ICD recipients were excluded from our database because of the low incidence of events. In a retrospective analysis, appropriate ICD therapy (both shocks and antitachycardia pacing due to ventricular tachyarrhythmias) occurred in 31.9% of 320 male patients who had received an ICD for primary prevention (median follow-up of 2.3 years), and in 55.1% of 423 male patients who had received an ICD for secondary prevention (median follow-up of 3.9 years). Compared to normal low GGT plasma levels (below 28 U/L), total mortality but not risk for appropriate ICD therapy was elevated for higher GGT categories (p for trend = 0.004 in primary prevention and p for trend = 0.002 in secondary prevention, respectively). In Cox regression analysis, elevated GGT (>56 U/L) remained an independent predictor of death both in primary (p = 0.011) and in secondary prevention (p = 0.006). Patients with elevated GGT and renal insufficiency defined by an estimated glomerular filtration rate <60 ml/min/1.73 m(2) suffered from excess total mortality jeopardizing the benefit of ICD therapy. CONCLUSION: Elevation of GGT is an important adverse prognostic parameter in ICD patients. A possible role of GGT for improved patient selection for ICD therapy deserves further investigation
    corecore