74 research outputs found

    An improved method to determine PM-bound nitro-PAHs in ambient air

    Get PDF
    Nowadays, no a standard method for the determination of particulate bound nitro-PAHs (NPAHs) has been developed. Existing methods include complex sampling and extraction procedures. Moreover, their sensitivity does not allow to analyze daily PM10 samples, affecting the temporal resolution of NPAH concentrations. In this study an analytical method for the quantification of NPAHs on half 47 mm-filter samples of daily PM10 was developed and validated. NPAHs were recovered by microwave-assisted extraction, and analyzed by using a gas chromatography-triple quadrupole mass spectrometry in MRM mode. The analytical performance for 14 NPAHs (2-nitrofluorene, 9-nitroanthracene, 9-nitrophenantrene, 3-nitrophenantrene, 2-nitroanthracene, 3-nitrofluoranthene, 1-nitropyrene, 2,7-dinitrofluorene, 7-nitrobenzo[a]anthracene, 6-nitrochrysene, 1,3-dinitropyrene, 1,8-dinitropyrene, 1,6-dinitropyrene, 6-nitrobenza[a]pyrene) was investigated. Recovery extraction percentage exceeded 95% for all target compounds in the range between 0.25 and 10 ng/mL. The repeatability, expressed as Relative Standard Deviation percentage (RSD%) of five determinations, was less than 10% for target compounds except for 2,7-dinitrofluorene, 1,3- and 1,8-dinitropyrene (RSD% < 15%). The limit of detection (LOD) ranged from 12 to 84 pg/mL for most of NPAHs, except for dinitro-pyrenes and nitro-benzo(a)anthracene for which the LOD reached 1.8 ng/mL. The method developed was applied to real samples in order to evaluate the levels of NPAHs in the urban and industrial area of Taranto (South of Italy). The analysis of PM10 samples collected at four industrial and one urban sites, highlighted that in proximity of critical emission source as the biggest European steel plant and under certain weather conditions, combustion processes were the main source of NPAHs in atmosphere

    Late time response analysis in UWB radar for concealed weapon detection : feasibility study

    Get PDF
    Remote detection of body-worn concealed weapons or explosives (CWE) is a field of ongoing research. In this Thesis the feasibility of CWE detection by using the UWB radar is explored. The CWE detection is based on the analysis of the Late Time Response (LTR) of the human which has been illuminated by the UWB signal. A specific set of LTR parameters characterizes the target signature. Therefore the existence of a CWE attached on the human body will influence the LTR characteristics and give the composite object i.e. human-CWE a different signature than the simple object i.e. human. The CWE detection methodology is verified by theoretical analysis, modelling and extensive laboratory experimentation. Investigation of the way the LTR parameters are influenced by the existence of the CWE signifies the differences of the LTR signature between the human and human-CWE. So the resolution of the differences in the LTR of a human with and without a CWE as the main objective of the research, are presented in the Thesis. The results verify that CWE detection with the use of LTR is feasible under the experimental conditions presented. Furthermore consideration of all possible detection scenarios is out of the scope of this Thesis.EThOS - Electronic Theses Online ServiceGBUnited Kingdo

    Review of low-cost sensors for indoor air quality: Features and applications

    Get PDF
    Humans spend the majority of their time indoors, where they are potentially exposed to hazardous pollutants. Within this context, over the past few years, there has been an upsurge of low-cost sensors (LCS) for the measurement of indoor air pollutants, motivated both by recent technological advances and by increased awareness of indoor air quality (IAQ) and its potential negative health impacts. Although not meeting the performance requirements for reference regulatory-equivalent monitoring indoors, LCS can provide informative measurements, offering an opportunity for high-resolution monitoring, emission source identification, exposure mitigation and managing IAQ and energy efficiency, among others. This article discusses the strengths and limitations that LCS offer for applications in the field of IAQ monitoring; it provides an overview of existing sensor technologies and gives recommendations for different indoor applications, considering their performance in the complex indoor environment and discussing future trends

    SARS-CoV-2 RNA Recovery from Air Sampled on Quartz Fiber Filters: A Matter of Sample Preservation?

    Get PDF
    The airborne route of transmission of SARS-CoV-2 was confirmed by the World Health Organization in April 2021. There is an urge to establish standardized protocols for assessing the concentration of SARS-CoV-2 RNA in air samples to support risk assessment, especially in indoor environments. Debates on the airborne transmission route of SARS-CoV-2 have been complicated because, among the studies testing the presence of the virus in the air, the percentage of positive samples has often been very low. In the present study, we report preliminary results on a study for the evaluation of parameters that can influence SARS-CoV-2 RNA recovery from quartz fiber filters spotted either by standard single-stranded SARS-CoV-2 RNA or by inactivated SARS-CoV-2 virions. The analytes were spiked on filters and underwent an active or passive sampling; then, they were preserved at −80 °C for different numbers of days (0 to 54) before extraction and analysis. We found a mean recovery of 2.43%, except for the sample not preserved (0 days) that showed a recovery of 13.51%. We found a relationship between the number of days and the recovery percentage. The results presented show a possible issue that relates to the quartz matrix and SARS-CoV-2 RNA recovery. The results are in accordance with the already published studies that described similar methods for SARS-CoV-2 RNA field sampling and that reported non-detectable concentrations of RNA. These outcomes could be false negatives due to sample preservation conditions. Thus, until further investigation, we suggest, as possible alternatives, to keep the filters: (i) in a sealed container for preservation at 4 °C; and (ii) in a viral transport medium for preservation at a temperature below 0 °C.This research was funded by University of Trieste Atheneum Fund for scientific research (2021) and IRCCS Burlo Garofolo (RC47/20)

    Results of the first European Source Apportionment intercomparison for Receptor and Chemical Transport Models

    Get PDF
    In this study, the performance of the source apportionment model applications were evaluated by comparing the model results provided by 44 participants adopting a methodology based on performance indicators: z-scores and RMSEu, with pre-established acceptability criteria. Involving models based on completely different and independent input data, such as receptor models (RMs) and chemical transport models (CTMs), provided a unique opportunity to cross-validate them. In addition, comparing the modelled source chemical profiles, with those measured directly at the source contributed to corroborate the chemical profile of the tested model results. The most used RM was EPA- PMF5. RMs showed very good performance for the overall dataset (91% of z-scores accepted) and more difficulties are observed with SCE time series (72% of RMSEu accepted). Industry resulted the most problematic source for RMs due to the high variability among participants. Also the results obtained with CTMs were quite comparable to their ensemble reference using all models for the overall average (>92% of successful z-scores) while the comparability of the time series is more problematic (between 58% and 77% of the candidates’ RMSEu are accepted). In the CTM models a gap was observed between the sum of source contributions and the gravimetric PM10 mass likely due to PM underestimation in the base case. Interestingly, when only the tagged species CTM results were used in the reference, the differences between the two CTM approaches (brute force and tagged species) were evident. In this case the percentage of candidates passing the z-score and RMSEu tests were only 50% and 86%, respectively. CTMs showed good comparability with RMs for the overall dataset (83% of the z-scores accepted), more differences were observed when dealing with the time series of the single source categories. In this case the share of successful RMSEu was in the range 25% - 34%.JRC.C.5-Air and Climat

    Breath Analysis: Comparison among Methodological Approaches for Breath Sampling

    No full text
    Despite promising results obtained in the early diagnosis of several pathologies, breath analysis still remains an unused technique in clinical practice due to the lack of breath sampling standardized procedures able to guarantee a good repeatability and comparability of results. The most diffuse on an international scale breath sampling method uses polymeric bags, but, recently, devices named Mistral and ReCIVA, able to directly concentrate volatile organic compounds (VOCs) onto sorbent tubes, have been developed and launched on the market. In order to explore performances of these new automatic devices with respect to sampling in the polymeric bag and to study the differences in VOCs profile when whole or alveolar breath is collected and when pulmonary wash out with clean air is done, a tailored experimental design was developed. Three different breath sampling approaches were compared: (a) whole breath sampling by means of Tedlar bags, (b) the end-tidal breath collection using the Mistral sampler, and (c) the simultaneous collection of the whole and alveolar breath by using the ReCIVA. The obtained results showed that alveolar fraction of breath was relatively less affected by ambient air (AA) contaminants (p-values equal to 0.04 for Mistral and 0.002 for ReCIVA Low) with respect to whole breath (p-values equal to 0.97 for ReCIVA Whole). Compared to Tedlar bags, coherent results were obtained by using Mistral while lower VOCs levels were detected for samples (both breath and AA) collected by ReCIVA, likely due to uncorrected and fluctuating flow rates applied by this device. Finally, the analysis of all data also including data obtained by explorative analysis of the unique lung cancer (LC) breath sample showed that a clean air supply might determine a further confounding factor in breath analysis considering that lung wash-out is species-dependent

    Monitoring techniques for PM and its composition

    No full text
    This chapter discusses the most used methodologies for PM measurement and its chemical characterization. Nowadays, many different instruments and analytical techniques for these purposes are available and the choice of the most suitable one depends on the aim of measurement; therefore, the principles of the methods for PM measurement will be briefly described. Regarding PM chemical composition, techniques for determination of identifiable components, organic and inorganic, will be presented. An overview on conventional techniques and new generation instruments designed to meet the various. goals of the monitoring will also be provided

    An integrated approach using high time-resolved tools to study the origin of aerosols

    No full text
    Long-range transport of natural and/or anthropogenic particles can contribute significantly to PM10 and PM2.5 concentrations and some European cities often fail to comply with PM daily limit values due to the additional impact of particles from remote sources. For this reason, reliable methodologies to identify long-range transport (LRT) events would be useful to better understand air pollution phenomena and support proper decision-making.This study explores the potential of an integrated and high time-resolved monitoring approach for the identification and characterization of local, regional and long-range transport events of high PM. In particular, the goal of this work was also the identification of time-limited event. For this purpose, a high time-resolved monitoring campaign was carried out at an urban background site in Bari (southern Italy) for about 20days (1st-20th October 2011). The integration of collected data as the hourly measurements of inorganic ions in PM2.5 and their gas precursors and of the natural radioactivity, in addition to the analyses of aerosol maps and hourly back trajectories (BT), provided useful information for the identification and chemical characterization of local sources and trans-boundary intrusions. Non-sea salt (nss) sulfate levels were found to increase when air masses came from northeastern Europe and higher dispersive conditions of the atmosphere were detected. Instead, higher nitrate and lower nss-sulfate concentrations were registered in correspondence with air mass stagnation and attributed to local traffic source. In some cases, combinations of local and trans-boundary sources were observed. Finally, statistical investigations such as the principal component analysis (PCA) applied on hourly ion concentrations and the cluster analyses, the Potential Source Contribution Function (PSCF) and the Concentration Weighted Trajectory (CWT) models computed on hourly back-trajectories enabled to complete a cognitive framework and confirm the influence of aerosol transported from heavily polluted areas on the receptor site
    • 

    corecore