16 research outputs found
Efficient system for bulk characterization of cryogenic CMOS components
Semiconductor integrated circuits operated at cryogenic temperature will play an essential role in quantum computing architectures. These can offer equivalent or superior performance to their room-temperature counterparts while enabling a scaling up of the total number of qubits under control. Silicon integrated circuits can be operated at a temperature stage of a cryogenic system where cooling power is sufficient (∼3.5+ K) to allow for analog signal chain components (e.g. amplifiers and mixers), local signal synthesis, signal digitization, and control logic. A critical stage in cryo-electronics development is the characterization of individual transistor devices in a particular technology node at cryogenic temperatures. This data enables the creation of a process design kit (PDK) to model devices and simulate integrated circuits operating well below the minimum standard temperature ranges covered by foundry-released models (e.g. -55 °C). Here, an efficient approach to the characterization of large numbers of components at cryogenic temperature is reported. We developed a system to perform DC measurements with Kelvin sense of individual transistors at 4.2 K using integrated on-die multiplexers, enabling bulk characterization of thousands of devices with no physical change to the measurement setup
Rapid cryogenic characterisation of 1024 integrated silicon quantum dots
Quantum computers are nearing the thousand qubit mark, with the current focus
on scaling to improve computational performance. As quantum processors grow in
complexity, new challenges arise such as the management of device variability
and the interface with supporting electronics. Spin qubits in silicon quantum
dots are poised to address these challenges with their proven control
fidelities and potential for compatibility with large-scale integration. Here,
we demonstrate the integration of 1024 silicon quantum dots with on-chip
digital and analogue electronics, all operating below 1 K. A high-frequency
analogue multiplexer provides fast access to all devices with minimal
electrical connections, enabling characteristic data across the quantum dot
array to be acquired in just 5 minutes. We achieve this by leveraging
radio-frequency reflectometry with state-of-the-art signal integrity, reaching
a minimum integration time of 160 ps. Key quantum dot parameters are extracted
by fast automated machine learning routines to assess quantum dot yield and
understand the impact of device design. We find correlations between quantum
dot parameters and room temperature transistor behaviour that may be used as a
proxy for in-line process monitoring. Our results show how rapid large-scale
studies of silicon quantum devices can be performed at lower temperatures and
measurement rates orders of magnitude faster than current probing techniques,
and form a platform for the future on-chip addressing of large scale qubit
arrays.Comment: Main text: 14 pages, 8 figures, 1 table Supplementary: 8 pages, 6
figure
Radiation and Dust Sensor for Mars Environmental Dynamic Analyzer Onboard M2020 Rover
32 pags., 26 figs., 3 tabs. -- This article belongs to the Section Remote SensorsThe Radiation and Dust Sensor is one of six sensors of the Mars Environmental Dynamics Analyzer onboard the Perseverance rover from the Mars 2020 NASA mission. Its primary goal is to characterize the airbone dust in the Mars atmosphere, inferring its concentration, shape and optical properties. Thanks to its geometry, the sensor will be capable of studying dust-lifting processes with a high temporal resolution and high spatial coverage. Thanks to its multiwavelength design, it will characterize the solar spectrum from Mars' surface. The present work describes the sensor design from the scientific and technical requirements, the qualification processes to demonstrate its endurance on Mars' surface, the calibration activities to demonstrate its performance, and its validation campaign in a representative Mars analog. As a result of this process, we obtained a very compact sensor, fully digital, with a mass below 1 kg and exceptional power consumption and data budget features.This work has been funded with the help of the Spanish National Research, Development
and Innovation Program, through the grants RTI2018-099825-B-C31, ESP2016-80320-C2-1-R and
ESP2014-54256-C4-3-R. DT acknowledges the financial support from the Comunidad de Madrid
for an “Atracción de Talento Investigador” grant (2018-T2/TIC10500). ASL is supported by Grant
PID2019-109467GB-I00 funded by MCIN/AEI/10.13039/501100011033/ and by Grupos Gobierno
Vasco IT1366-19. The US co-authors performed their work under sponsorship from NASA’s Mars
2020 project, from the Game Changing Development program within the Space Technology Mission
Directorate, and from the Human Exploration and Operations Directorate.Peer reviewe
Measurement of cryoelectronics heating using a local quantum dot thermometer in silicon
Silicon technology offers the enticing opportunity for monolithic integration of quantum and classical electronic circuits. However, the power consumption levels of classical electronics may compromise the local chip temperature and hence affect the fidelity of qubit operations. In the current work, a quantum-dot-based thermometer embedded in an industry-standard silicon field-effect transistor (FET) was adopted to assess the local temperature increase produced by an active FET placed in close proximity. The impact of both static and dynamic operation regimes was thoroughly investigated. When the FET was operated statically, a power budget of 45 nW at 100-nm separation was found, whereas at 216 μm, the power budget was raised to 150 μW. Negligible temperature increase for the switch frequencies tested up to 10 MHz was observed when operating dynamically. The current work introduced a method to accurately map out the available power budget at a distance from a solid-state quantum processor, and indicated the possible conditions under which cryoelectronics circuits may allow the operation of hybrid quantum–classical systems
Observations of the climate near the surface of Jezero over a half Mars year
International audiencePerseverance landed on Jezero with the most complete suite of environmental sensors ever sent to the surface of another planet. It combines the Mars Environmental Dynamics Analyzer (MEDA), the MastCam-Z and Engineering cameras, SuperCam spectrometers and, finally, the several microphones onboard the Mars 2020 rover. The most recent collection of atmospheric observations at Jezero and their interpretation are building an understanding of what physical processes drive the behavior of the Martian atmosphere near the surface of Jezero. We report on the observed Martian cycles of pressure, temperature, dust opacity with their physical aerosol properties, and the hydrological cycle at Jezero. These cycles have shown different behaviors on time scales from diurnal to seasonal and annual to other locations where we landed before. The differences illustrate the range of environmental processes that one can find near the red planet’s surface. We also report on the observed evolution of the near-surface boundary layer thermodynamics during the day and nighttime regimes
Observations of the climate near the surface of Jezero over a half Mars year
International audiencePerseverance landed on Jezero with the most complete suite of environmental sensors ever sent to the surface of another planet. It combines the Mars Environmental Dynamics Analyzer (MEDA), the MastCam-Z and Engineering cameras, SuperCam spectrometers and, finally, the several microphones onboard the Mars 2020 rover. The most recent collection of atmospheric observations at Jezero and their interpretation are building an understanding of what physical processes drive the behavior of the Martian atmosphere near the surface of Jezero. We report on the observed Martian cycles of pressure, temperature, dust opacity with their physical aerosol properties, and the hydrological cycle at Jezero. These cycles have shown different behaviors on time scales from diurnal to seasonal and annual to other locations where we landed before. The differences illustrate the range of environmental processes that one can find near the red planet’s surface. We also report on the observed evolution of the near-surface boundary layer thermodynamics during the day and nighttime regimes
Switching TNF antagonists in patients with chronic arthritis: An observational study of 488 patients over a four-year period
The objective of this work is to analyze the survival of infliximab, etanercept and adalimumab in patients who have switched among tumor necrosis factor (TNF) antagonists for the treatment of chronic arthritis. BIOBADASER is a national registry of patients with different forms of chronic arthritis who are treated with biologics. Using this registry, we have analyzed patient switching of TNF antagonists. The cumulative discontinuation rate was calculated using the actuarial method. The log-rank test was used to compare survival curves, and Cox regression models were used to assess independent factors associated with discontinuing medication. Between February 2000 and September 2004, 4,706 patients were registered in BIOBADASER, of whom 68% had rheumatoid arthritis, 11% ankylosing spondylitis, 10% psoriatic arthritis, and 11% other forms of chronic arthritis. One- and two-year drug survival rates of the TNF antagonist were 0.83 and 0.75, respectively. There were 488 patients treated with more than one TNF antagonist. In this situation, survival of the second TNF antagonist decreased to 0.68 and 0.60 at 1 and 2 years, respectively. Survival was better in patients replacing the first TNF antagonist because of adverse events (hazard ratio (HR) for discontinuation 0.55 (95% confidence interval (CI), 0.34-0.84)), and worse in patients older than 60 years (HR 1.10 (95% CI 0.97-2.49)) or who were treated with infliximab (HR 3.22 (95% CI 2.13-4.87)). In summary, in patients who require continuous therapy and have failed to respond to a TNF antagonist, replacement with a different TNF antagonist may be of use under certain situations. This issue will deserve continuous reassessment with the arrival of new medications. © 2006 Gomez-Reino and Loreto Carmona; licensee BioMed Central Ltd
Centrality dependence of the charged-particle multiplicity density at mid-rapidity in Pb-Pb collisions at = 2.76 TeV
The centrality dependence of the charged-particle multiplicity density at mid-rapidity in Pb-Pb collisions at = 2.76 TeV is presented. The charged-particle density normalized per participating nucleon pair increases by about a factor 2 from peripheral (70-80%) to central (0-5%) collisions. The centrality dependence is found to be similar to that observed at lower collision energies. The data are compared with models based on different mechanisms for particle production in nuclear collisions.The centrality dependence of the charged-particle multiplicity density at mid-rapidity in Pb-Pb collisions at = 2.76 TeV is presented. The charged-particle density normalized per participating nucleon pair increases by about a factor 2 from peripheral (70-80%) to central (0-5%) collisions. The centrality dependence is found to be similar to that observed at lower collision energies. The data are compared with models based on different mechanisms for particle production in nuclear collisions