93 research outputs found

    Multi-channel SPR biosensor based on PCF for multi-analyte sensing applications

    Get PDF
    This paper presents a theoretical investigation of a novel holey fiber (Photonic Crystal Fiber (PCF)) multi-channel biosensor based on surface plasmon resonance (SPR). The large gold coated micro fluidic channels and elliptical air hole design of our proposed biosensor aided by a high refractive index over layer in two channels enables operation in two modes; multi analyte sensing and self-referencing mode. Loss spectra, dispersion and detection capability of our proposed biosensor for the two fundamental modes (HE x 11 and HE y 11 ) have been elucidated using a Finite Element Method (FEM) and Perfectly Matching Layers (PML)

    Limited versus full sternotomy for aortic valve replacement

    Get PDF
    Copyright \ua9 2023 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd. BACKGROUND: Aortic valve disease is a common condition easily treatable with cardiac surgery. This is conventionally performed by opening the sternum (\u27median sternotomy\u27) and replacing the valve under cardiopulmonary bypass. Median sternotomy is well tolerated, but as less invasive options become available, the efficacy of limited incisions has been called into question. In particular, the effects of reducing the visibility and surgical access have raised safety concerns with regard to the placement of cannulae, venting of the heart, epicardial wire placement, and de-airing of the heart at the end of the procedure. These difficulties may increase operating times, affecting outcome. The benefits of smaller incisions are thought to include decreased pain; improved respiratory mechanics; reductions in wound infections, bleeding, and need for transfusion; shorter intensive care stay; better cosmesis; and a quicker return to normal activity. This is an update of a Cochrane review first published in 2017, with seven new studies. OBJECTIVES: To assess the effects of minimally invasive aortic valve replacement via a limited sternotomy versus conventional aortic valve replacement via median sternotomy in people with aortic valve disease requiring surgical replacement. SEARCH METHODS: We performed searches of CENTRAL, MEDLINE and Embase from inception to August 2021, with no language limitations. We also searched two clinical trials registries and manufacturers\u27 websites. We reviewed references of primary studies to identify any further studies of relevance. SELECTION CRITERIA: We included randomised controlled trials comparing aortic valve replacement via a median sternotomy versus aortic valve replacement via a limited sternotomy. We excluded trials that performed other minimally invasive incisions such as mini-thoracotomies, port access, transapical, transfemoral or robotic procedures. Although some well-conducted prospective and retrospective case-control and cohort studies exist, these were not included in this review. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial papers to extract data, assess quality, and identify risk of bias. A third review author provided arbitration where required. We determined the certainty of evidence using the GRADE methodology and summarised results of patient-relevant outcomes in a summary of findings table. MAIN RESULTS: The review included 14 trials with 1395 participants. Most studies had at least two domains at high risk of bias. We analysed 14 outcomes investigating the effects of minimally invasive limited upper hemi-sternotomy on aortic valve replacement as compared to surgery performed via full median sternotomy. Upper hemi-sternotomy may have little to no effect on mortality versus full median sternotomy (risk ratio (RR) 0.93, 95% confidence interval (CI) 0.45 to 1.94; 10 studies, 985 participants; low-certainty evidence). Upper hemi-sternotomy for aortic valve replacement may increase cardiopulmonary bypass time slightly, although the evidence is very uncertain (mean difference (MD) 10.63 minutes, 95% CI 3.39 to 17.88; 10 studies, 1043 participants; very low-certainty evidence) and may increase aortic cross-clamp time slightly (MD 6.07 minutes, 95% CI 0.79 to 11.35; 12 studies, 1235 participants; very low-certainty evidence), although the evidence is very uncertain. Most studies had at least two domains at high risk of bias. Postoperative blood loss was probably lower in the upper hemi-sternotomy group (MD -153 mL, 95% CI -246 to -60; 8 studies, 767 participants; moderate-certainty evidence). Low-certainty evidence suggested that there may be no change in pain scores by upper hemi-sternotomy (standardised mean difference (SMD) -0.19, 95% CI -0.43 to 0.04; 5 studies, 649 participants). Upper hemi-sternotomy may result in little to no difference in quality of life (MD 0.03 higher, 95% CI 0 to 0.06 higher; 4 studies, 624 participants; low-certainty evidence). Two studies reporting index admission costs concluded that limited sternotomy may be more costly at index admission in the UK National Health Service (MD 1190 GBP more, 95% CI 420 GBP to 1970 GBP, 2 studies, 492 participants; low-certainty evidence). AUTHORS\u27 CONCLUSIONS: The evidence was of very low to moderate certainty. Sample sizes were small and underpowered to demonstrate differences in some outcomes. Clinical heterogeneity was also noted. Considering these limitations, there may be little to no effect on mortality. Differences in extracorporeal support times are uncertain, comparing upper hemi-sternotomy to full sternotomy for aortic valve replacement. Before widespread adoption of the minimally invasive approach can be recommended, there is a need for a well-designed and adequately powered prospective randomised controlled trial. Such a study would benefit from also performing a robust cost analysis. Growing patient preference for minimally invasive techniques merits thorough quality of life analyses to be included as end points, as well as quantitative measures of physiological reserve

    Performance assessment off a commercial scale solar biomass hybrid dryer for quality seed maize production: Presentation

    Get PDF
    Though several maize varieties have been developed and introduced over the years in Ghana, farmers still face challenges of access to quality seed maize. Among the major constraints is lack of proper drying systems to quarantee quality of seed produced. Peculiar to most parts of Africa, drying of maize in the open, on bare ground along shoulders of roads is still a common practice in Ghana. In this study, a 5-tonne capacity solar biomass hybrid dryer was developed for drying maize for seed and food/feed in Ghana. Effect of drying air temperature in the dryer on the physiological quality and germination of maize kernels was investigated. Maize grains were dried in the open sun simulating farmers practice and using the dryer at 4 varying levels (L1, L2, L3 and L4) with corresponding heights (0.6m, 1.2m, 1.8m and 2.4m) respectively. Harvested maize at 22.8% moisture content was dried at the varying levels until reaching overall mean moisture content of 12.8 ± 0.2% (wb). Results showed that, drying air temperatures in the dryer increased in accordance with height with lowest mean temperature of 44.4 ± 4.6°C recorded at L1 and mean maximum of 52.8 ± 5.4 °C at L4. The increase in drying temperature at L4 increased kernel stress crack index by an average of 14% and reduced germination by 33%. However, drying temperatures at L1-L3 and in the open sun had no significant effect (p > 0.05) on the germination potential of maize grains. This satisfies the dryer’s potential to be used for drying maize grains for high quality seed production on commercial scale.Though several maize varieties have been developed and introduced over the years in Ghana, farmers still face challenges of access to quality seed maize. Among the major constraints is lack of proper drying systems to quarantee quality of seed produced. Peculiar to most parts of Africa, drying of maize in the open, on bare ground along shoulders of roads is still a common practice in Ghana. In this study, a 5-tonne capacity solar biomass hybrid dryer was developed for drying maize for seed and food/feed in Ghana. Effect of drying air temperature in the dryer on the physiological quality and germination of maize kernels was investigated. Maize grains were dried in the open sun simulating farmers practice and using the dryer at 4 varying levels (L1, L2, L3 and L4) with corresponding heights (0.6m, 1.2m, 1.8m and 2.4m) respectively. Harvested maize at 22.8% moisture content was dried at the varying levels until reaching overall mean moisture content of 12.8 ± 0.2% (wb). Results showed that, drying air temperatures in the dryer increased in accordance with height with lowest mean temperature of 44.4 ± 4.6°C recorded at L1 and mean maximum of 52.8 ± 5.4 °C at L4. The increase in drying temperature at L4 increased kernel stress crack index by an average of 14% and reduced germination by 33%. However, drying temperatures at L1-L3 and in the open sun had no significant effect (p > 0.05) on the germination potential of maize grains. This satisfies the dryer’s potential to be used for drying maize grains for high quality seed production on commercial scale

    BISMICS consensus statement: implementing a safe minimally invasive mitral programme in the UK healthcare setting

    Get PDF
    Disseminating the practice of minimally invasive mitral surgery (mini-MVS) can be challenging, despite its original case reports a few decades ago. The penetration of this technology into clinical practice has been limited to centres of excellence and mitral surgery in most general cardiothoracic centres remains to be conducted via sternotomy access as a first line. The process for the uptake of mini-MVS requires clearer guidance and standardisation for the processes involved in its implementation. In this statement, a consensus agreement is outlined that describes the benefits of mini-MVS, including reduced post-operative bleeding, reduced wound infection, enhanced recovery and patient satisfaction. Technical considerations require specific attention and can introduced through simulation and/or use in conventional cases. Either endoballoon or aortic cross clamping are both recommended as well as femoral or central aortic cannulation, with the use of appropriate adjuncts and instruments. A coordinated team-based approach that encourages ownership of the programme by the team members is critical. A designated proctor is also recommended. The organisation of structured training and simulation, as well as planning the initial cases are important steps to consider. The importance of pre-empting complications and dealing with adverse events are described, including re-exploration, conversion to sternotomy, uni-lateral pulmonary oedema and phrenic nerve injury. Accounting for both institutional and team considerations can effectively facilitate the introduction of a mini-MVS service. This involves simulation, team-based training, visits to specialist centres and involvement of a designated proctor to oversee the initial cases

    Changes in Inflammatory Response after Endovascular Treatment for Type B Aortic Dissection

    Get PDF
    This present study aims to investigate the changes in the inflammatory markers after elective endovascular treatment of Type B aortic dissection with aneurysm, as related to different anatomical features of the dissection flap in the paravisceral perfusion. Consecutive patients with type B aortic dissections with elective endovascular stent graft repair were recruited and categorized into different groups. Serial plasma levels of cytokines (Interleukin-1β, -6, -8, -10, TNF-α), chemokines (MCP-1), and serum creatinine were monitored at pre-, peri- and post-operative stages. The length of stent graft employed in each surgery was retrieved and correlated with the change of all studied biochemical parameters. A control group of aortic dissected patients with conventional medication management was recruited for comparing the baseline biochemical parameters. In total, 22 endovascular treated and 16 aortic dissected patients with surveillance were recruited. The endovascular treated patients had comparable baseline levels as the non-surgical patients. There was no immediate or thirty day-mortality, and none of the surgical patients developed post-operative mesenteric ischaemia or clinically significant renal impairment. All surgical patients had detectable pro-inflammatory mediators, but none of the them showed any statistical significant surge in the peri-operative period except IL-1β and IL-6. Similar results were obtained when categorized into different groups. IL-1β and IL-6 showed maximal levels within hours of the endovascular procedure (range, 3.93 to 27.3 higher than baseline; p = 0.001), but returned to baseline 1 day post-operatively. The change of IL-1β and IL-6 at the stent graft deployment was statistically greater in longer stent graft (p>0.05). No significant changes were observed in the serum creatinine levels. In conclusion, elective endovascular repair of type B aortic dissection associated with insignificant changes in inflammatory mediators and creatinine. All levels fell toward basal levels post-operatively suggesting that thoracic endovascular aortic repair is rather less aggressive with insignificant inflammatory modulation

    Increasing incidence and mortality of infective endocarditis: a population-based study through a record-linkage system

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Few population-based studies provide epidemiological data on infective endocarditis (IE). Aim of the study is to analyze incidence and outcomes of IE in the Veneto Region (North-Eastern Italy).</p> <p>Methods</p> <p>Residents with a first hospitalization for IE in 2000-2008 were extracted from discharge data and linked to mortality records to estimate 365-days survival. Etiology was retrieved in subsets of this cohort by discharge codes and by linkage to a microbiological database. Risk factors for mortality were assessed through logistic regression.</p> <p>Results</p> <p>1,863 subjects were hospitalized for IE, with a corresponding crude rate of 4.4 per 100,000 person-years, increasing from 4.1 in 2000-2002 to 4.9 in 2006-2008 (p = 0.003). Median age was 68 years; 39% of subjects were hospitalized in the three preceding months. 23% of patients underwent a cardiac valve procedure in the index admission or in the following year. Inhospital mortality was 14% (19% including hospital transfers); 90-days and 365-days mortality rose through the study years. Mortality increased with age and the Charlson comorbidity index, in subjects with previous hospitalizations for heart failure, and (in the subcohort with microbiological data) in IE due to Staphylococci (40% of IE).</p> <p>Conclusions</p> <p>The study demonstrates an increasing incidence and mortality for IE over the last decade. Analyses of electronic archives provide a region-wide picture of IE, overcoming referral biases affecting single clinic or multicentric studies, and therefore represent a first fundamental step to detect critical issues related to IE.</p

    Determinants of outcomes following surgery for type A acute aortic dissection: the UK National Adult Cardiac Surgical Audit

    Get PDF
    Aims  Operability of type A acute aortic dissections (TAAAD) is currently based on non-standardized decision-making process, and it lacks a disease-specific risk evaluation model that can predict mortality. We investigated patient, intraoperative data, surgeon, and centre-related variables for patients who underwent TAAAD in the UK. Methods and results We identified 4203 patients undergoing TAAAD surgery in the UK (2009–18), who were enrolled into the UK National Adult Cardiac Surgical Audit dataset. The primary outcome was operative mortality. A multivariable logistic regression analysis was performed with fast backward elimination of variables and the bootstrap-based optimism-correction was adopted to assess model performance. Variation related to hospital or surgeon effects were quantified by a generalized mixed linear model and risk-adjusted funnel plots by displaying the individual standardized mortality ratio against expected deaths. Final variables retained in the model were: age [odds ratio (OR) 1.02, 95% confidence interval (CI) 1.02–1.03; P < 0.001]; malperfusion (OR 1.79, 95% CI 1.51–2.12; P < 0.001); left ventricular ejection fraction (moderate: OR 1.40, 95% CI 1.14–1.71; P = 0.001; poor: OR 2.83, 95% CI 1.90–4.21; P < 0.001); previous cardiac surgery (OR 2.29, 95% CI 1.71–3.07; P < 0.001); preoperative mechanical ventilation (OR 2.76, 95% CI 2.00–3.80; P < 0.001); preoperative resuscitation (OR 3.36, 95% CI 1.14–9.87; P = 0.028); and concomitant coronary artery bypass grafting (OR 2.29, 95% CI 1.86–2.83; P < 0.001). We found a significant inverse relationship between surgeons but not centre annual volume with outcomes. Conclusions  Patient characteristics, intraoperative factors, cardiac centre, and high-volume surgeons are strong determinants of outcomes following TAAAD surgery. These findings may help refining clinical decision-making, supporting patient counselling and be used by policy makers for quality assurance and service provision improvement

    Design and analysis of novel photonic crystal fibre and waveguide surface plasmon resonance biosensors operating in aqueous environments

    No full text
    Surface plasmon resonance (SPR) sensors provide high sensitivity without the use of molecular labels. Most commercial SPR biosensors are based on the simple, robust and highly sensitive traditional prism-coupled configuration. However, they are not amenable to miniaturization and integration. This has led to a growing interest in the development of robust, portable and highly sensitive SPR sensing devices capable of out of laboratory measurements. This thesis covers the modelling of these sensors, using the full vectorial finite element and the eigenmode expansion methods with the aim of optimising the proposed sensors for operation in aqueous environments. The thesis focuses on designs based on photonic crystal fibres and planar waveguides to achieve highly sensitive and compact platforms capable of multi analyte I channel operation. It is no longer feasible to optimise designs by simply fabricating and testing a large set of possible alternatives. This can be time consuming for complex devices such as SPR sensors. This requires computer models which can simulate the behaviour of the different designs in an accurate and speedy manner. This will make it possible to accurately predict device performance characteristics for different material and structural configurations, thereby affording designers the opportunity to experiment with different system configurations for optimal performance. In order to maintain modelling accuracy, all materials are modelled as dispersive and a full-wave analysis is undertaken. to account for the important frequency dependent effects. At every stage in this research, .,care was taken to bench-mark our results against the best available data, whether numerical or analytical whenever available, in order to validate our work. The effects of structural and material parameters on sensor performance metrics such as sensitivity are thoroughly investigated to arrive at optimised designs.EThOS - Electronic Theses Online ServiceGBUnited Kingdo
    corecore