12 research outputs found

    Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology: A Multicenter Blinded Randomized Noninferiority Study of 1992 Cases (Pivotal Study)

    Get PDF
    Most prior studies of primary diagnosis in surgical pathology using whole slide imaging (WSI) versus microscopy have focused on specific organ systems or included relatively few cases. The objective of this study was to demonstrate that WSI is noninferior to microscopy for primary diagnosis in surgical pathology. A blinded randomized noninferiority study was conducted across the entire range of surgical pathology cases (biopsies and resections, including hematoxylin and eosin, immunohistochemistry, and special stains) from 4 institutions using the original sign-out diagnosis (baseline diagnosis) as the reference standard. Cases were scanned, converted to WSI and randomized. Sixteen pathologists interpreted cases by microscopy or WSI, followed by a wash-out period of ≥4 weeks, after which cases were read by the same observers using the other modality. Major discordances were identified by an adjudication panel, and the differences between major discordance rates for both microscopy (against the reference standard) and WSI (against the reference standard) were calculated. A total of 1992 cases were included, resulting in 15,925 reads. The major discordance rate with the reference standard diagnosis was 4.9% for WSI and 4.6% for microscopy. The difference between major discordance rates for microscopy and WSI was 0.4% (95% confidence interval, -0.30% to 1.01%). The difference in major discordance rates for WSI and microscopy was highest in endocrine pathology (1.8%), neoplastic kidney pathology (1.5%), urinary bladder pathology (1.3%), and gynecologic pathology (1.2%). Detailed analysis of these cases revealed no instances where interpretation by WSI was consistently inaccurate compared with microscopy for multiple observers. We conclude that WSI is noninferior to microscopy for primary diagnosis in surgical pathology, including biopsies and resections stained with hematoxylin and eosin, immunohistochemistry and special stains. This conclusion is valid across a wide variety of organ systems and specimen types

    Current state of the regulatory trajectory for whole slide imaging devices in the USA

    No full text
    The regulatory field for digital pathology (DP) has advanced significantly. A major milestone was accomplished when the FDA allowed the first vendor to market their device for primary diagnostic use in the USA and published in the classification order that this device, and substantially equivalent devices of this generic type, should be classified into class II instead of class III as previously proposed. The Digital Pathology Association (DPA) regulatory task force had a major role in the accomplishment of getting the application request for Whole Slide Imaging (WSI) Systems recommended for a de novo. This article reviews the past and emerging regulatory environment of WSI for clinical use in the USA. A WSI system with integrated subsystems is defined in the context of medical device regulations. The FDA technical performance assessment guideline is also discussed as well as parameters involved in analytical testing and clinical studies to demonstrate that WSI devices are safe and effective for clinical use

    PIcc: REGULATORY SCIENCE EXPLAINED

    No full text

    Sa région en une gorgée

    No full text
    Background and objective The present randomized, safety-assessor blinded, placebo-controlled trial was designed to assess safety and efficacy of sugammadex, a novel selective relaxant-binding agent, in patients with underlying cardiovascular disease undergoing noncardiac surgery. Methods Overall, 116 patients (New York Heart Association class II-III) were randomized and received sugammadex 2.0 mg kg(-1) (n = 38), sugammadex 4.0 mg kg(-1) (n = 38) or placebo (n=40) for reversal of rocuronium-induced neuromuscular blockade at reappearance of T2. Safety variables included heart rate, blood pressure and electrocardiogram characteristics, including rate-corrected QT (QTc Fridericia and QTc Bazett) interval. Efficacy was evaluated as time to recovery of the T4/T1 ratio to 0.9 after administration of sugammadex or placebo. Results There were no significant differences between groups in terms of QTc (Fridericia) interval. Three serious adverse events, one in each treatment group, considered to be possibly drug-related according to the investigator, were cases of mild QTc (Bazett) interval prolongation. Blood pressure and heart rate decreased after initiation of anaesthesia and remained stable in all groups up to 10 min after administration of study drug. Blood pressure was significantly higher (P <0.05) in both sugammadex dose groups compared with placebo at 30 min. The decrease in heart rate from baseline (prestudy drug) was significantly greater in the 2.0 mg kg(-1) sugammadex group at 2 and 5 min, and, for both sugammadex groups, the increase at 30 min was greater compared with placebo. Both sugammadex doses resulted in considerably shorter time to recovery of the T4/T1 ratio to 0.9 compared with placebo. Conclusion The findings indicate sugammadex 2.0 and 4.0 mg kg(-1) can be given safely and effectively for the reversal of rocuronium-induced neuromuscular blockade in patients with cardiovascular disease undergoing noncardiac surgery. EurJAnaesthesiol 26:874-884 (C) 2009 European Society of Anaesthesiolog

    Objective and Subjective Assessment of Digital Pathology Image Quality

    No full text
    The quality of an image produced by the Whole Slide Imaging (WSI) scanners is of critical importance for using the image in clinical diagnosis. Therefore, it is very important to monitor and ensure the quality of images. Since subjective image quality assessments by pathologists are very time-consuming, expensive and difficult to reproduce, we propose a method for objective assessment based on clinically relevant and perceptual image parameters: sharpness, contrast, brightness, uniform illumination and color separation; derived from a survey of pathologists. We developed techniques to quantify the parameters based on content-dependent absolute pixel performance and to manipulate the parameters in a predefined range resulting in images with content-independent relative quality measures. The method does not require a prior reference model. A subjective assessment of the image quality is performed involving 69 pathologists and 372 images (including 12 optimal quality images and their distorted versions per parameter at 6 different levels). To address the inter-reader variability, a representative rating is determined as a one-tailed 95% confidence interval of the mean rating. The results of the subjective assessment support the validity of the proposed objective image quality assessment method to model the readers’ perception of image quality. The subjective assessment also provides thresholds for determining the acceptable level of objective quality per parameter. The images for both the subjective and objective quality assessment are based on the HercepTestTM slides scanned by the Philips Ultra Fast Scanners, developed at Philips Digital Pathology Solutions. However, the method is applicable also to other types of slides and scanners

    Computational pathology definitions, best practices, and recommendations for regulatory guidance: a white paper from the Digital Pathology Association

    No full text
    In this white paper, experts from the Digital Pathology Association (DPA) define terminology and concepts in the emerging field of computational pathology, with a focus on its application to histology images analyzed together with their associated patient data to extract information. This review offers a historical perspective and describes the potential clinical benefits from research and applications in this field, as well as significant obstacles to adoption. Best practices for implementing computational pathology workflows are presented. These include infrastructure considerations, acquisition of training data, quality assessments, as well as regulatory, ethical, and cyber-security concerns. Recommendations are provided for regulators, vendors, and computational pathology practitioners in order to facilitate progress in the field. (c) 2019 The Authors. The Journal of Pathology published by John Wiley amp; Sons Ltd on behalf of Pathological Society of Great Britain and Ireland

    Digital Imaging and Communications in Medicine Whole Slide Imaging Connectathon at Digital Pathology Association Pathology Visions 2017

    No full text
    As digital pathology systems for clinical diagnostic work applications become mainstream, interoperability between these systems from different vendors becomes critical. For the first time, multiple digital pathology vendors have publicly revealed the use of the digital imaging and communications in medicine (DICOM) standard file format and network protocol to communicate between separate whole slide acquisition, storage, and viewing components. Note the use of DICOM for clinical diagnostic applications is still to be validated in the United States. The successful demonstration shows that the DICOM standard is fundamentally sound, though many lessons were learned. These lessons will be incorporated as incremental improvements in the standard, provide more detailed profiles to constrain variation for specific use cases, and offer educational material for implementers. Future Connectathon events will expand the scope to include more devices and vendors, as well as more ambitious use cases including laboratory information system integration and annotation for image analysis, as well as more geographic diversity. Users should request DICOM features in all purchases and contracts. It is anticipated that the growth of DICOM-compliant manufacturers will likely also ease DICOM for pathology becoming a recognized standard and as such the regulatory pathway for digital pathology products
    corecore