230 research outputs found

    It is Hobbes, not Rousseau:an experiment on voting and redistribution

    Get PDF
    We perform an experiment which provides a laboratory replica of some important features of the welfare state. In the experiment, all individuals in a group decide whether to make a costly effort, which produces a random (independent) outcome for each one of them. The group members then vote on whether to redistribute the resulting and commonly known total sum of earnings equally amongst themselves. This game has two equilibria, if played once. In one of them, all players make effort and there is little redistribution. In the other one, there is no effort and nothingWe thank Iris Bohnet, Tim Cason, David Cooper, John Duffy, Maia Guell, John Van Huyck and Robin Mason for helpful conversations and encouragement. The comments of the Editor and two referees helped improve the paper. We gratefully acknowledge the financial support from Spain’s Ministry of Science and Innovation under grants CONSOLIDER INGENIO 2010 CSD2006-0016 (all authors), ECO2009-10531 (Cabrales), ECO2008-01768 (Nagel) and the Comunidad de Madrid under grant Excelecon (Cabrales), the Generalitat de Catalunya and the CREA program (Nagel), and project SEJ2007-64340 of Spain’s Ministerio de Educación y Ciencia (Rodríguez Mora).Publicad

    Ground State Vortex Lattice Structures in d-wave Superconductors

    Get PDF
    We show in a realistic dx2y2d_{x^{2}-y^{2}} symmetry gap model for a cuprate superconductor that the clean vortex lattice has discontinuous structural transitions (at and near T=0), as a function of the magnetic field BB along the c-axis. The transitions arise from the singular nonlocal and anisotropic susceptibility of the dx2y2d_{x^{2}-y^{2}} superconductor to the perturbation caused by supercurrents associated with vortices. The susceptibility, due to virtual Dirac quasiparticle-hole excitation, is calculated carefully, and leads to a ground state transition for the triangular lattice from an orientation along one of the crystal axis to one at 45o^o to them, i.e, along the gap zero direction. The field scale is seen to be 5 Tesla (Δ0/ta)2Φ0 \sim (\Delta_{0}/ta)^{2}\Phi_{0}, where Δ0\Delta_{0} is the gap maximum, tt is the nearest neighbour hopping, aa is the lattice constant, and Φ0\Phi_{0} is the flux quantum. At much higher fields (28T\sim 28T) there is a discontinuous transition to a centred square structure. The source of the differences from existing calculations, and experimental observability are discussed, the latter especially in view of the very small (a few degrees KK per vortex) differences in the ground state energy.Comment: To be published in Phys. Rev.

    Cardiovascular Biomarkers in Cardio-Oncology: Antineoplastic Drug Cardiotoxicity and Beyond

    Get PDF
    Serum biomarkers represent a reproducible, sensitive, minimally invasive and inexpensive method to explore possible adverse cardiovascular effects of antineoplastic treatments. They are useful tools in risk stratification, the early detection of cardiotoxicity and the follow-up and prognostic assessment of cancer patients. In this literature review, we aim at describing the current state of knowledge on the meaning and the usefulness of cardiovascular biomarkers in patients with cancer; analyzing the intricate relationship between cancer and cardiovascular disease (especially HF) and how this affects cardiovascular and tumor biomarkers; exploring the role of cardiovascular biomarkers in the risk stratification and in the identification of chemotherapy-induced cardiotoxicity; and providing a summary of the novel potential biomarkers in this clinical setting

    Gaining insight into how women conceptualize satisfaction: Western Australian women's perception of their maternity care experiences

    Get PDF
    BACKGROUND: The concept of maternal satisfaction is challenging, as women's and clinicians' expectations and experiences can differ. Our aim was to investigate women's experiences of maternity care in an urban tertiary obstetric setting, to gain insight into conceptualization of satisfaction across the childbirth continuum. METHODS: This mixed method study was conducted at a public maternity hospital in Western Australia. A questionnaire was sent to 733 women two weeks post birth, which included an invitation for an audio-recorded, telephone interview. Frequency distributions and univariate comparisons were employed for quantitative data. Thematic analysis of interview transcripts was undertaken to extract common themes. RESULTS: A total of 54 % (399 of 733) returned the questionnaire. Quantitative results indicated that women were less likely to feel: involved if they did not have a spontaneous vaginal birth (P?=?0.020); supported by a midwife if they had a caesarean (P?=?<0.001); or supported by an obstetrician if they had a spontaneous vaginal birth (P?=?<0.001). Qualitative findings emerged from 63 interviews which highlighted the influence that organization of care, resources and facilities had on women's satisfaction. These paradigms unfolded as three broad themes constructed by four sub-themes, each illustrating a dichotomy of experiences. The first theme 'how care was provided' encompassed: familiar faces versus a different one every time and the best place to be as opposed to so disappointed. The second theme 'attributes of staff' included: above and beyond versus caring without caring and in good hands as opposed to handled incorrectly. The third theme 'engaged in care' incorporated: explained everything versus did not know why and had a choice as opposed to did not listen to my needs. CONCLUSIONS: Quantitative analysis confirmed that the majority of women surveyed were satisfied. Mode of birth influenced women's perception of being involved with their birth. Being able to explore the diversity of women's experiences in relation to satisfaction with their maternity care in an urban, tertiary obstetric setting has offered greater insight into what women value: a sensitive, respectful, shared relationship with competent clinicians who recognise and strive to provide woman focused care across the childbirth continuum

    Lung-to-Heart Nano-in-Micro Peptide Promotes Cardiac Recovery in a Pig Model of Chronic Heart Failure

    Get PDF
    Background: The lack of disease-modifying drugs is one of the major unmet needs in patients with heart failure (HF). Peptides are highly selective molecules with the potential to act directly on cardiomyocytes. However, a strategy for effective delivery of therapeutics to the heart is lacking. Objectives: In this study, the authors sought to assess tolerability and efficacy of an inhalable lung-to-heart nano-in-micro technology (LungToHeartNIM) for cardiac-specific targeting of a mimetic peptide (MP), a first-in-class for modulating impaired L-type calcium channel (LTCC) trafficking, in a clinically relevant porcine model of HF. Methods: Heart failure with reduced ejection fraction (HFrEF) was induced in Göttingen minipigs by means of tachypacing over 6 weeks. In a setting of overt HFrEF (left ventricular ejection fraction [LVEF] 30% ± 8%), animals were randomized and treatment was started after 4 weeks of tachypacing. HFrEF animals inhaled either a dry powder composed of mannitol-based microparticles embedding biocompatible MP-loaded calcium phosphate nanoparticles (dpCaP-MP) or the LungToHeartNIM only (dpCaP without MP). Efficacy was evaluated with the use of echocardiography, invasive hemodynamics, and biomarker assessment. Results: DpCaP-MP inhalation restored systolic function, as shown by an absolute LVEF increase over the treatment period of 17% ± 6%, while reversing cardiac remodeling and reducing pulmonary congestion. The effect was recapitulated ex vivo in cardiac myofibrils from treated HF animals. The treatment was well tolerated, and no adverse events occurred. Conclusions: The overall tolerability of LungToHeartNIM along with the beneficial effects of the LTCC modulator point toward a game-changing treatment for HFrEF patients, also demonstrating the effective delivery of a therapeutic peptide to the diseased heart

    Development of Cheaper Embryo Vitrification Device Using the Minimum Volume Method

    Full text link
    [EN] This study was designed to compare the efficiency of the Cryotop and Calibrated plastic inoculation loop (CPIL) devices for vitrification of rabbit embryos on in vitro development and implantation rate, offspring rate at birth and embryonic and fetal losses. CPIL is a simple tool used mainly by microbiologists to retrieve an inoculum from a culture of microorganisms. In experiment 1, embryos were vitrified using a Cryotop device and a CPIL device. There were no significant differences in hatched/hatching blastocyst stage rates after 48 h of culture among the vitrified groups (62±4.7% and 62±4.9%, respectively); however, the rates were significantly lower (P<0.05) than those of the fresh group (95±3.4%). In experiment 2, vitrified embryos were transferred using laparoscopic technique. The number of implanted embryos was estimated by laparoscopy as number of implantation sites at day 14 of gestation. At birth, total offspring were recorded. Embryonic and fetal losses were calculated as the difference between implanted embryos and embryos transferred and total born at birth and implanted embryos, respectively. The rate of implantation and development to term was similar between both vitrification devices (56±7.2% and 50±6.8% for implantation rate and 40±7.1% and 35±6.5% for offspring rate at birth); but significantly lower than in the fresh group (78±6.6% for implantation rate and 70±7.2% for offspring rate at birth, P<0.05). Likewise, embryonic losses were similar between both vitrification devices (44±7.2% and 50±6.8%), but significantly higher than in the fresh group (23±6.6%, P < 0.05). However, fetal losses were similar between groups (10±4.4%, 15±4.8% and 8±4.2%, for vitrified, Cryotop or CPIL and fresh, respectively). These results indicate that the CPIL device is as effective as the Cryotop device for vitrification of rabbit embryos, but at a cost of 0.05 per device.This research was supported by the projects Spanish Research project AGL2014-53405-C2-1-P Comision Interministerial de Ciencia y Tecnologia (FMJ, JSV) and Generalitat Valenciana research program (Prometeo II 2014/036, JSV, FMJ).Marco Jiménez, F.; Jiménez Trigos, ME.; Almela-Miralles, V.; Vicente Antón, JS. (2016). Development of Cheaper Embryo Vitrification Device Using the Minimum Volume Method. PLoS ONE. 11(2):1-9. https://doi.org/10.1371/journal.pone.0148661S1911
    corecore