38 research outputs found

    Bond between glass fibre reinforced polymer bars and high - strength concrete

    Get PDF
    YesIn this study, bond properties of glass fibre reinforced polymer (GFRP) bars embedded in high-strength concrete (HSC) were experimentally investigated using a pull-out test. The experimental program consisted of testing 84 pull-out specimens prepared according to ACI 440.3R-12 standard. The testing of the specimens was carried out considering bar diameter (9.5, 12.7 and 15.9 mm), embedment length (2.5, 5, 7.5 and 10 times bar diameter) and surface configuration (helical wrapping with slight sand coating (HW-SC) and sand coating (SC)) as the main parameters. Twelve pull-out specimens reinforced with 16 mm steel bar were also tested for comparison purposes. Most of the specimens failed by a pull-out mode. Visual inspection of the tested specimens reinforced with GFRP (HW-SC) bars showed that the pull-out failure was due to the damage of outer bar surface, whilst the detachment of the sand coating was responsible for the bond failure of GFRP (SC) reinforced specimens. The bond stress – slip behaviour of GFRP (HW-SC) bars is different from that of GFRP (SC) bars and it was also found that GFRP (SC) bars gave a better bond performance than GFRP (HW-SC) bars. It was observed that the reduction rate of bond strength of both GFRP types with increasing the bar diameter and the embedment length was reduced in the case of high-strength concrete. Bond strength predictions obtained from ACI-440.1R, CSAeS806, CSA-S6 and JSCE design codes were compared with the experimental results. Overall, all design guidelines were conservative in predicting bond strength of both GFRP bars in HSC and ACI predictions were closer to the tested results than other codes

    Axial load-axial deformation behaviour of circular concrete columns reinforced with GFRP bars and helices

    Get PDF
    Fibre Reinforced Polymer (FRP) bars has attracted a significant amount of research attention in the last three decades to overcome the problems associated with the corrosion of steel reinforcing bars in reinforced concrete members. A limited number of studies, however, have investigated the behaviour of concrete columns reinforced with FRP bars. Also, available design standards either ignore the contribution of or do not recommend the use of GFRP bars in compression members. This study reports the results of experimental investigations of concrete specimens reinforced with GFRP bars and GFRP helices as longitudinal and transverse reinforcement, respectively. A total of five circular concrete columns of 205 mm in diameter and 800 mm in height were cast and tested under axial compression. The experimental results showed that reducing the spacing of the GFRP helices or confining the specimens with CFRP sheet led to improvements in the strength and ductility of the specimens. Also, an analytical model has been developed for the axial load-axial deformation behaviour of the circular concrete columns reinforced with GFRP bars and helices. The model has been validated with the experimental results
    corecore