2,031 research outputs found

    The gamma-ray emission from 3HWC J1928+178

    Get PDF
    The gamma-ray source 3HWC J1928+178, discovered by HAWC, is coincident with the 82 kyr pulsar PSR J1928+1746, located 4 kpc away. It has not been reported by any Imaging atmospheric Cherenkov Telescope (IACT), until the recent detection of emission from this region by H.E.S.S., using an analysis adapted to extended sources. No counterpart in GeV gamma-rays from Fermi-LAT data or in X-ray has been reported so far. In this contribution, I give the multiwavelength context of the region surrounding 3HWC J1928+178 and present a multi-component model derived using the Multi-Mission Maximum Likelihood framework (3ML). I explore the possibility to model the gamma-ray emission of 3HWC J1928+178 by an extended source with continuous diffuse emission. Together with the age of the pulsar and its extended nature, it may indicate a transition from a pulsar wind nebulae to a halo, where the electrons have started to cool and diffuse away from the source

    Gaussian process tomography for soft x-ray spectroscopy at WEST without equilibrium information

    Get PDF
    International audienceGaussian process tomography (GPT) is a recently developed tomography method based on the Bayesian probability theory [J. Svensson, JET Internal Report EFDA-JET-PR(11)24, 2011 and Li et al., Rev. Sci. Instrum. 84, 083506 (2013)]. By modeling the soft X-ray (SXR) emissivity field in a poloidal cross section as a Gaussian process, the Bayesian SXR tomography can be carried out in a robust and extremely fast way. Owing to the short execution time of the algorithm, GPT is an important candidate for providing real-time reconstructions with a view to impurity transport and fast magnetohydrodynamic control. In addition, the Bayesian formalism allows quantifying uncertainty on the inferred parameters. In this paper, the GPT technique is validated using a synthetic data set expected from the WEST tokamak, and the results are shown of its application to the reconstruction of SXR emissivity profiles measured on Tore Supra. The method is compared with the standard algorithm based on minimization of the Fisher information

    Construction and measurements of a vacuum-swing-adsorption radon-mitigation system

    Full text link
    Long-lived alpha and beta emitters in the 222^{222}Rn decay chain on (and near) detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double-beta decay, and in screening detectors. In order to reduce backgrounds from radon-daughter plate-out onto the wires of the BetaCage during its assembly, an ultra-low-radon cleanroom is being commissioned at Syracuse University using a vacuum-swing-adsorption radon-mitigation system. The radon filter shows ~20×\times reduction at its output, from 7.47±\pm0.56 to 0.37±\pm0.12 Bq/m3^3, and the cleanroom radon activity meets project requirements, with a lowest achieved value consistent with that of the filter, and levels consistently < 2 Bq/m3^3.Comment: 5 pages, 3 figures, Proceedings of Low Radioactivity Techniques (LRT) 2013, Gran Sasso, Italy, April 10-12, 201

    Non-existence of normal tokamak equilibria with negative central current

    Get PDF
    Recent tokamak experiments employing off-axis, non-inductive current drive have found that a large central current hole can be produced. The current density is measured to be approximately zero in this region, though in principle there was sufficient current drive power for the central current density to have gone significantly negative. Recent papers have used a large aspect-ratio expansion to show that normal MHD equilibria (with axisymmetric nested flux surfaces, non-singular fields, and monotonic peaked pressure profiles) can not exist with negative central current. We extend that proof here to arbitrary aspect ratio, using a variant of the virial theorem to derive a relatively simple integral constraint on the equilibrium. However, this constraint does not, by itself, exclude equilibria with non-nested flux surfaces, or equilibria with singular fields and/or hollow pressure profiles that may be spontaneously generated.Comment: 5 pages, 3 figures. Submitted to Physics of Plasmas, Feb. 14, 2003. Revised Feb. 24, 2003. Vers. 2: revised May 29 to clarify points raised by referee, add references to recent work. July 18, accepted for publicatio

    Comparison of two regularization methods for Soft x-ray tomography at Tore Supra

    Get PDF
    International audienceSoft x-ray (SXR) emission in the range 0.1-20 keV is widely used to obtain valuable information on tokamak plasma physics, such as particle transport, magnetic configuration or magnetohydrodynamic activity. In particular, 2D tomography is the usual plasma diagnostic to access the local SXR emissivity. The tomographic inversion is traditionally performed from lineintegrated measurements of two or more cameras viewing the plasma in a poloidal cross-section, like at Tore Supra (TS). Unfortunately, due to the limited number of measured projections and presence of noise, the tomographic reconstruction of SXR emissivity is a mathematical ill-posed problem. Thus, obtaining reliable results of the tomographic inversion is a very challenging task. In order to perform the reconstruction, inversion algorithms implemented in present tokamaks use a priori information as additional constraints imposed on the plasma SXR emissivity. Among several potential inversion methods, some of them have been identified as well suited to tokamak plasmas. The purpose of this work is to compare two promising inversion methods, i.e. the minimum fisher information method already used at TS and planned for WEST configuration, and the alternative 2nd order Phillips-Tikhonov regularization with smoothness constraints imposed on the second derivative norm. Respective accuracy of both reconstruction methods as well as overall robustness and computational time are studied, using several synthetic SXR emissivity profiles. Finally, a real case is studied through tomographic reconstruction from TS SXR database

    Latest news from the HAWC outrigger array

    Get PDF
    The High Altitude Water Cherenkov (HAWC) observatory is a very high energy gamma-ray detector located in Mexico. In late 2018, the HAWC collaboration completed a major upgrade consisting of the addition of a sparse outrigger array of 345 small water Cherenkov detectors (WCDs) surrounding the 300 WCDs of the main array and extending the instrumented area by a factor of 4. It provides an improved reconstruction of the showers whose core and footprint are not well contained in the array and increases the effective area in the range of a few TeV to beyond 100 TeV. This improvement in sensitivity will help to have a better understanding of the Galactic sources that accelerate particles up to the knee of the cosmic ray spectrum. In this contribution, we will show the current status, the performance, and the first results from the HAWC outrigger array

    Measurement of the 0.511 MeV gamma ray line from the Galactic Center

    Get PDF
    The detection of the 0.511 MeV electron positron annihilation line coming from the Galactic Center to provide the means to estimate the rate of positron production and to test some theoretical sources of positrons is addressed. The results of the measurements of the 0.511 MeV line flux made with a gamma ray experiment on board a stratospheric balloon are presented. The detector field of view looked at the galactic longitude range -31 deg l(II) +41 deg. The observed flux is 0.0067 (+ or - 0.0005) photons 1/cm(2)5 which is in very good agreement with the expected flux when assuming that the Galactic Center is a line source emitting uniformly
    • …
    corecore