27,986 research outputs found

    A unified acquisition system for acoustic data

    Get PDF
    A multichannel, acoustic AM carrier system was developed for a wide variety of applications, particularly for aircraft noise and sonic boom measurements. Each data acquisition channel consists of a condenser microphone, an acoustic signal converter, and a Zero Drive amplifier, along with peripheral supporting equipment. A control network insures continuous optimal tuning of the converter and permits remote calibration of the condenser microphone. With a 12.70-mm (1/2-in.) condenser microphone, the converter/Zero Drive amplifier combination has a frequency response from 0 Hz to 20 kHz (-3 db), a dynamic range exceeding 70 db, and a minimum noise floor of 50 db ref. 20 micro Pa) in the band 22.4 Hz to 22.4 kHz. The system requires no external impedance matching networks and is insensitive to cable length, at least up to 900 m (3,000 ft). System gain varies only + or - 1 db over the temperature range 4 to 54 C (40 to 130 F). Adapters are available to accommodate 23.77-mm (1-in.) and 6.35-mm (1/4-in.) microphones and to provide 30-db attenuation. A field test to obtain the acoustical time history of a helicopter flyover proved successful

    Imagery Rescripting : The Impact of Conceptual and Perceptual Changes on Aversive Autobiographical Memories

    Get PDF
    BACKGROUND: Imagery rescripting (ImRs) is a process by which aversive autobiographical memories are rendered less unpleasant or emotional. ImRs is thought only to be effective if a change in the meaning-relevant (semantic) content of the mental image is produced, according to a cognitive hypothesis of ImRs. We propose an additional hypothesis: that ImRs can also be effective by the manipulation of perceptual features of the memory, without explicitly targeting meaning-relevant content. METHODS: In two experiments using a within-subjects design (both N = 48, community samples), both Conceptual-ImRs-focusing on changing meaning-relevant content-and Perceptual-ImRs-focusing on changing perceptual features-were compared to Recall-only of aversive autobiographical image-based memories. An active control condition, Recall + Attentional Breathing (Recall+AB) was added in the first experiment. In the second experiment, a Positive-ImRs condition was added-changing the aversive image into a positive image that was unrelated to the aversive autobiographical memory. Effects on the aversive memory's unpleasantness, vividness and emotionality were investigated. RESULTS: In Experiment 1, compared to Recall-only, both Conceptual-ImRs and Perceptual-ImRs led to greater decreases in unpleasantness, and Perceptual-ImRs led to greater decreases in emotionality of memories. In Experiment 2, the effects on unpleasantness were not replicated, and both Conceptual-ImRs and Perceptual-ImRs led to greater decreases in emotionality, compared to Recall-only, as did Positive-ImRs. There were no effects on vividness, and the ImRs conditions did not differ significantly from Recall+AB. CONCLUSIONS: Results suggest that, in addition to traditional forms of ImRs, targeting the meaning-relevant content of an image during ImRs, relatively simple techniques focusing on perceptual aspects or positive imagery might also yield benefits. Findings require replication and extension to clinical samples

    A transient heat transfer and thermodynamic analysis of the Apollo service module propulsion system. Vol. I, phase I - Transient thermal analysis Final report, 28 Jul. 1964 - 28 Jul. 1965

    Get PDF
    Transient heat transfer and thermodynamic behavior analysis for Apollo service module propulsion system - fuel cell effect on overheatin

    Alternative derivation of the Feigel effect and call for its experimental verification

    Full text link
    A recent theory by Feigel [Phys. Rev. Lett. {\bf 92}, 020404 (2004)] predicts the finite transfer of momentum from the quantum vacuum to a fluid placed in strong perpendicular electric and magnetic fields. The momentum transfer arises because of the optically anisotropic magnetoelectric response induced in the fluid by the fields. After summarising Feigel's original assumptions and derivation (corrected of trivial mistakes), we rederive the same result by a simpler route, validating Feigel's semi-classical approach. We then derive the stress exerted by the vacuum on the fluid which, if the Feigel hypothesis is correct, should induce a Poiseuille flow in a tube with maximum speed ā‰ˆ100Ī¼\approx 100\mum/s (2000 times larger than Feigel's original prediction). An experiment is suggested to test this prediction for an organometallic fluid in a tube passing through the bore of a high strength magnet. The predicted flow can be measured directly by tracking microscopy or indirectly by measuring the flow rate (ā‰ˆ1\approx 1ml/min) corresponding to the Poiseuille flow. A second experiment is also proposed whereby a `vacuum radiometer' is used to test a recent prediction that the net force on a magnetoelectric slab in the vacuum should be zero.Comment: 20 pages, 1 figures. revised and improved versio

    Anisotropy, disorder, and superconductivity in CeCu2Si2 under high pressure

    Full text link
    Resistivity measurements were carried out up to 8 GPa on single crystal and polycrystalline samples of CeCu2Si2 from differing sources in the homogeneity range. The anisotropic response to current direction and small uniaxial stresses was explored, taking advantage of the quasi-hydrostatic environment of the Bridgman anvil cell. It was found that both the superconducting transition temperature Tc and the normal state properties are very sensitive to uniaxial stress, which leads to a shift of the valence instability pressure Pv and a small but significant change in Tc for different orientations with respect to the tetragonal c-axis. Coexistence of superconductivity and residual resistivity close to the Ioffe-Regel limit around 5 GPa provides a compelling argument for the existence of a valence-fluctuation mediated pairing interaction at high pressure in CeCu2Si2.Comment: 12 pages, 7 figure

    Recommendations to support deprescribing medications late in life

    Get PDF
    It is widely acknowledged that patientsā€”particularly those late in lifeā€”are frequently exposed to the harms of medication. To minimize these harms, several frameworks have been developed by which prescribing can be optimized. In the context of diminishing life expectancy, these frameworks can be used to reduce medications that are no longer necessary, but appear to fall short of actual guidelines that incorporate a consideration of stopping medications. In this commentary, we present recommendations that could be incorporated into prescribing processes for all healthcare professionals and, ultimately, used to support the rationalization or deprescribing of medication in diminished life expectancy. We frame these recommendations in the same context as guidance for the initiation and discontinuation of implantable cardiac devices and argue that the two processesā€”with regards to decision-makingā€”should be the same. We present our recommendations with preventive medication use in mind, and use statin therapy as an illustrative example

    Data mining in bioinformatics using Weka

    Get PDF
    The Weka machine learning workbench provides a general purpose environment for automatic classification, regression, clustering and feature selection-common data mining problems in bioinformatics research. It contains an extensive collection of machine learning algorithms and data exploration and the experimental comparison of different machine learning techniques on the same problem. Weka can process data given in the form of a single relational table. Its main objectives are to (a) assist users in extracting useful information from data and (b) enable them to easily identify a suitable algorithm for generating an accurate predictive model from it
    • ā€¦
    corecore