424 research outputs found

    New system and methodology for avoiding calibers in ceramic tile production

    Get PDF
    MACER, S.L, in collaboration with the Institute of Ceramic Technology, has developed a comprehensive control system of the pressing operation called CALIBREUNICO® which keeps constant in time the bulk density of all the ceramic pieces shaped in an industrial press. The CALIBREUNICO® system consists of two subsystems that permit one hand, balance the variations in moisture spray-dried powder by the continuous regulation in real time of the pressure moulding and, secondly, regulate the load individually in each of the holes of the press with de purpose of equalling the bulk density of all pieces obtained in the same press cycle. CALIBREUNICO®, ensuring the constancy of bulk density of all pieces processed, guarantees a single piece size and the minimization of the production problems associated with variability in bulk density of the pieces.MACER, S.L., en colaboración con el Instituto de Tecnología Cerámica, ha desarrollado un sistema de control integral de la operación de prensado denominado CALIBREUNICO® que permite mantener constante en el tiempo la densidad aparente de todas las piezas cerámicas conformadas en una prensa industrial. El sistema CALIBREUNICO® está constituido por dos subsistemas complementarios que permiten, por un lado, compensar las variaciones de humedad del polvo atomizado mediante la regulación continua y en tiempo real de la presión de prensado y, por otro lado, regular la carga individualizada en cada uno de los alvéolos de la prensa con el fin de igualar la densidad aparente de todas las piezas obtenidas en un mismo ciclo de prensado. CALIBREUNICO®, al asegurar la constancia de la densidad aparente de todas las piezas procesadas, garantiza un único tamaño de pieza y la minimización de los problemas de producción asociados a la variabilidad de la densidad aparente de los soportes

    Nuevo sistema para la medida y control de la presión máxima de prensado en los alvéolos del molde: ISOPRESS®

    Get PDF
    The organization MACER, in collaboration with the Institute of Ceramic Technology, has developed the system ISOPRESS®, an integrated control device that permits to equal automatically the maximum pressure applied on the powder contained in each of the holes of the mould. This system consists of a set of pressure transducers which are located in the isostatic punches of the mould itself. With them it is possible to register in real-time the evolution of the measured pressure of the oil contained in the compensation chamber of each punch. All the transducers are connected to a data acquisition system which transfers the pressure values to a PC which performs the signal processing to obtain the pressure maximum value reached during a pressing cycle, in each one of the holes. The system is completed with a control software especially developed, that permits to regulate individually the height of the first fall of each inferior punch to guarantee the uniformity of the pressure applied in all the holes. ISOPRESS®, by assuring the constancy of the bulk density of all the pieces processed, guarantees a unique piece size and minimize production problems associated to the variability of the bulk density of the pieces

    DEM-based modelling framework for spray-dried powders in ceramic tiles industry. Part I: Calibration procedure

    Get PDF
    This work describes a combined experimental-numerical study to characterizefine spray-dried powder used inthe ceramic tile pressing process. A DEM-based granular assembly is endowed with a new set of scaling laws thatallows for simulating reliably industrial processes using a much lower number of granules. To do it, a calibrationstrategy relying on three experimental setups is proposed; (i) compression test of bulk for granule stiffness, (ii)dynamic angle of repose and (iii) image analysis of the powder motion in a rotating drum for the intergranularand granular-boundary sliding and rolling friction coefficients. In order to evaluate the powder motion in a rotat-ing drum, a robust method relying on a direct image analysis is proposed. This methodology makes it possible toquantitatively assess the frictional properties of the powder in contact with different surface materials

    Nuevo equipo para medir la distribución de la densidad aparente de piezas cerámicas: DENSEXPLORER

    Get PDF
    Este trabajo ha participado en la 38 edición de los premios Alfa de Oro, otorgados por la Sociedad Española de Cerámica y Vidrio, durante la Feria Internacional de Cerámica de Valencia CEVISAMA 2014 Densexplorer es el primer dispositivo capaz de determinar la distribución de la densidad aparente de baldosas cerámicas industriales de gran tamaño, de forma no destructiva, no perjudicial para la salud, respetuosa con el medio ambiente, incrementando la productividad respecto a los equipos actuales. El sistema está basado en la medida puntual de la absorción de rayos X y del espesor de la pieza.Densexplorer is the first device for industrial manufacturing plant capable of determining the distribution of bulk density of large ceramic tiles in a non-destructively way, which is not harmful to health, respectful with the environment and that increases the productivity of the process regarding to existing equipment. The system is based on the X-ray absorption technique, in which a material absorbs an amount of radiation depending on its thickness and density

    Validación de dos radioinmuneoensayos clínicos de hormonas tiroideas (T3 y T4) para el análisis de muestras de rata

    Get PDF
    Para emplear un método de radioinmunoensayo (RIA) en el análisis de muestras de diferente naturaleza de las muestras para las que fue desarrollado y validado, aunque haya identidad antigénica, es necesario validar nuevamente el método para comprobar la ausencia de interferencias analíticas. Se han realizado pruebas de validación (paralelismo, recuperación, precipitación inespecífica) en dos métodos comerciales de RIA para la determinación clínica de hormonas tiroideas (T3 y T4) al aplicarlos al análisis de muestras de suero de rata. El RIA de T4 no muestra paralelismo entre las muestras analizadas y la curva patrón, y la recuperación alcanza valores de 147,5%. De ello deducimos que en el RIA de T4 ensayado hay interferencias analíticas que no permiten la obtención de resultados válidos si se analizan muestras de suero de rata. El RIA de T3 ensayado cumple satisfactoriamente la prueba de paralelismo, la de recuperación, y la precipitación inespecífica es similar en las muestras de suero de rata y en la curva patrón. Por ello el RIA de T3 ensayado es válido para el análisis de muestras de suero de rata.When a radioimmunoasay method is used to analyze samples of a type different than these for wich it was developed, the method needs to be validated to asses the absence of analytical interferences even if antigenic identity exist. We have perfomed validation tests (parallelism, recovery and non specific binding) when applying two comercial RIA methods for clínical determination of thyroid hormones (T3, T4) to rat serum samples. The T 4 shows lack of parallelism between the samples analyzed and the standard curve, the recovery reaches values of 147,5%, so we infer the existence of analytical interferences in the RIA assayed wich precludes obtaining valid results when used to analyze rat serum samples. The T3 RIA assayed fullfills to satisfaction the parallelism test, the average recovery obtained is 95,7% and NSB in rat serum is similar to that of the standard curve, so we conclude this T). RIA is able for the sample analysis of rat serum

    Validación de dos radioinmuneoensayos clínicos de hormonas tiroideas (T3 y T4) para el análisis de muestras de rata

    Get PDF
    When a radioimmunoasay method is used to analyze samples of a type different than these for wich it was developed, the method needs to be validated to asses the absence of analytical interferences even if antigenic identity exist. We have perfomed validation tests (parallelism, recovery and non specific binding) when applying two comercial RIA methods for clínical determination of thyroid hormones (T3, T4) to rat serum samples. The T4 shows lack of parallelism between the samples analyzed and the standard curve, the recovery reaches values of 147,5%, so we infer the existence of analytical interferences in the RIA assayed wich precludes obtaining valid results when used to analyze rat serum samples. The T4 RIA assayed fullfills to satisfaction the parallelism test, the average recovery obtained is 95,7% and NSB in rat serum is similar to that of the standard curve, so we conclude this T). RIA is able for the sample analysis of rat serum.Para emplear un método de radioinmunoensayo (RIA) en el análisis de muestras de diferente naturaleza de las muestras para las que fue desarrollado y validado, aunque haya identidad antigénica, es necesario validar nuevamente el método para comprobar la ausencia de interferencias analíticas. Se han realizado pruebas de validación (paralelismo, recuperación, precipitación inespecífica) en dos métodos comerciales de RIA para la determinación clínica de hormonas tiroideas (T3 y T4) al aplicarlos al análisis de muestras de suero de rata. El RIA de T4 no muestra paralelismo entre las muestras analizadas y la curva patrón, y la recuperación alcanza valores de 147,5%. De ello deducimos que en el RIA de T4 ensayado hay interferencias analíticas que no permiten la obtención de resultados válidos si se analizan muestras de suero de rata. El RIA de T3 ensayado cumple satisfactoriamente la prueba de paralelismo, la de recuperación, y la precipitación inespecífica es similar en las muestras de suero de rata y en la curva patrón. Por ello el RIA de T3 ensayado es válido para el análisis de muestras de suero de rata
    corecore