242 research outputs found

    Establishing local reference intervals for full blood count and white blood cell differential counts in Cape Town, South Africa

    Get PDF
    Background. Accurate laboratory reference intervals (RIs) are essential to differentiate between health and disease. There are variations in haematological indices within populations relating to gender, age, ethnicity and environment. Iron deficiency is common, has a wide range of clinical morbidities and affects red cell indices. Locally derived RIs for full blood count (FBC) parameters are needed for the Western Cape region of South Africa, after the exclusion of iron deficiency. In addition, information regarding the prevalence of iron deficiency in first-time blood donors would inform blood transfusion services regarding policies to screen for and treat iron deficiency.Objectives. To establish locally derived RIs for FBC and white blood cell (WBC) differential count parameters in healthy adults in the Cape Town area, by including first-time blood donors and excluding those with iron deficiency and thalassaemic indices. These new locally established RIs could update those in use by the local National Health Laboratory Service. A secondary objective was to establish the prevalence of iron deficiency in first-time blood donors. This would inform blood donation policies regarding screening and appropriate iron supplementation in high-risk groups prior to blood donation.Methods. This was a prospective, descriptive study with direct convenience sampling. Participants were prospective voluntary blood donors aged between 18 and 60 years, presenting for first-time blood donation. Ethnicity was self-identified. Participants who tested positive for HIV or hepatitis B and/or C viruses were excluded. Prospective participants with iron deficiency, defined by serum ferritin levels below the RI, and those with red cell indices suggestive of an underlying thalassaemia trait were excluded. FBC samples were analysed using a Sysmex XN-1000 cell counter. Statistical non-parametric methods were used to calculate the RIs, according to international guidelines.Results. Of the 774 participants screened, 82 (11%) had iron deficiency and were excluded. Six hundred and sixty-two patients were included for analysis, 409 (62%) female and 253 (38%) male. The majority of the participants, 348 (53%), were between 20 and 29 years of age, with a mean age of 29 years for females and 28 years for males. Participants comprised a mix of the various ethnic groups residing in Western Cape Province. The mean haemoglobin concentration for females was lower than that for males (p<0.0001). There were significant gender differences for total WBC count, absolute neutrophil count and platelet count, with females having higher counts than males.Conclusions. Locally established, population-specific RIs are essential for the accurate interpretation of haematological indices. This study established locally derived gender-specific RIs for the Cape Town region, after exclusion of iron deficiency. These new RIs have implications for the accurate diagnoses of cytopenias, cytoses and other blood count abnormalities. Iron deficiency is common in first-time blood donors, and screening for iron deficiency using point-of-care testing should be considered

    A collaborative and evolving response to the needs of frontline workers, patients and families during the COVID-19 pandemic at Tygerberg Hospital, Western Cape Province, South Africa

    Get PDF
    The global devastation caused by the COVID-19 pandemic and its mental health impact is undeniable. The physical and psychological consequences are wide-ranging – affecting patients fighting the disease, frontline workers in the trenches with them, healthcare staff deployed in high-care settings, and families disconnected from their loved ones in their darkest hours. Within 6 weeks of the COVID-19 outbreak in South Africa, the Department of Psychiatry at Stellenbosch University established the TBH/SU COVID Resiliency Clinic to provide psychological support to frontline workers at Tygerberg Hospital. Identified barriers in healthcare workers accessing mental healthcare resulted in moving towards an on-site visibility to try to remove some of these barriers. This greater on-site presence enabled networking and building of relationships with frontline staff that over time highlighted other frontline needs, such as providing psychosocial and spiritual support to patients and their families. We share challenges, lessons learned and recommendations from two initiatives: the TBH/SU COVID-19 Resiliency Clinic, and an embedded COVID Care Team (CCT). We describe the establishment, roll-out and progress of the Clinic and the subsequent CCT

    Comparative study on energy consumption at the University of Johannesburg residences

    Get PDF
    Abstract: This study evaluates the pattern of energy usage at the twenty-eight residences of the University of Johannesburg during the 2016 academic year. The study investigates the trend of energy consumption based on total energy usage per residence in terms of the number of students at each of the residences on a monthly and daily basis. The data employed in this study were collected over a period of eleven months which is the overall effective academic calendar. The results obtained showed a contrast between the total energy usage per residence and energy usage per student. Sophia town residence recorded the highest total annual energy usage of 149286 kWh while Takalani residence recorded the least which was 97093 kWh of all the residences considered in this study. However, when energy consumption was measured as a function of number of students in each residence, Goudstad residence recorded the highest monthly energy usage per student (450.69 kWh), followed by YMCA (389.09 kWh) while the least monthly energy usage of 51.30 kWh was recorded in Maqhawe residence. Similarly, results obtained from the study on daily energy usage per student in the last five months of the 2016 academic year showed Goudstad residence (23.32 kWh) and YMCA (20.34) as the two residences with the highest daily energy usage per student respectively. However, the energy usage does not follow a regular pattern within the period under consideration

    Minimally invasive classification of pediatric solid tumors using reduced representation bisulfite sequencing of cell-free DNA : a proof-of-principle study

    Get PDF
    In the clinical management of pediatric solid tumors, histological examination of tumor tissue obtained by a biopsy remains the gold standard to establish a conclusive pathological diagnosis. The DNA methylation pattern of a tumor is known to correlate with the histopathological diagnosis across cancer types and is showing promise in the diagnostic workup of tumor samples. This methylation pattern can be detected in the cell-free DNA. Here, we provide proof-of-concept of histopathologic classification of pediatric tumors using cell-free reduced representation bisulfite sequencing (cf-RRBS) from retrospectively collected plasma and cerebrospinal fluid samples. We determined the correct tumor type in 49 out of 60 (81.6%) samples starting from minute amounts (less than 10 ng) of cell-free DNA. We demonstrate that the majority of misclassifications were associated with sample quality and not with the extent of disease. Our approach has the potential to help tackle some of the remaining diagnostic challenges in pediatric oncology in a cost-effective and minimally invasive manner. Translational relevance: Obtaining a correct diagnosis in pediatric oncology can be challenging in some tumor types, especially in renal tumors or central nervous system tumors. Furthermore, the diagnostic odyssey can result in anxiety and discomfort for these children. By applying a novel technique, reduced representation bisulfite sequencing on cell-free DNA (cf-RRBS), we show the feasibility of obtaining the histopathological diagnosis with a minimally invasive test on either plasma or cerebrospinal fluid. Furthermore, we were able to derive the copy number profile or tumor subtype from the same assay. Given that primary tumor material might be difficult to obtain, in particular in critically ill children or depending on the tumor location, and might be limited in terms of quantity or quality, our assay could become complementary to the classical tissue biopsy in difficult cases

    Thermal and electrical conductivity of iron at Earth's core conditions

    Get PDF
    The Earth acts as a gigantic heat engine driven by decay of radiogenic isotopes and slow cooling, which gives rise to plate tectonics, volcanoes, and mountain building. Another key product is the geomagnetic field, generated in the liquid iron core by a dynamo running on heat released by cooling and freezing to grow the solid inner core, and on chemical convection due to light elements expelled from the liquid on freezing. The power supplied to the geodynamo, measured by the heat-flux across the core-mantle boundary (CMB), places constraints on Earth's evolution. Estimates of CMB heat-flux depend on properties of iron mixtures under the extreme pressure and temperature conditions in the core, most critically on the thermal and electrical conductivities. These quantities remain poorly known because of inherent difficulties in experimentation and theory. Here we use density functional theory to compute these conductivities in liquid iron mixtures at core conditions from first principles- the first directly computed values that do not rely on estimates based on extrapolations. The mixtures of Fe, O, S, and Si are taken from earlier work and fit the seismologically-determined core density and inner-core boundary density jump. We find both conductivities to be 2-3 times higher than estimates in current use. The changes are so large that core thermal histories and power requirements must be reassessed. New estimates of adiabatic heat-flux give 15-16 TW at the CMB, higher than present estimates of CMB heat-flux based on mantle convection; the top of the core must be thermally stratified and any convection in the upper core driven by chemical convection against the adverse thermal buoyancy or lateral variations in CMB heat flow. Power for the geodynamo is greatly restricted and future models of mantle evolution must incorporate a high CMB heat-flux and explain recent formation of the inner core.Comment: 11 pages including supplementary information, two figures. Scheduled to appear in Nature, April 201

    Acceptability of a novel levofloxacin dispersible tablet formulation in young children exposed to multidrug-resistant tuberculosis

    Get PDF
    Levofloxacin is used for the treatment and prevention of multidrug-resistant tuberculosis in children, but current adult formulations are poorly palatable. A questionnaire administered to caregivers of 27 children taking a novel 100 mg dispersible taste-masked levofloxacin tablet found the new formulation to be more palatable (69%) and easier to prepare (81%) than the adult formulation. This formulation may assist children to better adhere to anti-tuberculous therapy

    Modelling the effects of boundary walls on the fire dynamics of informal settlement dwellings

    Get PDF
    AbstractCharacterising the risk of the fire spread in informal settlements relies on the ability to understand compartment fires with boundary conditions that are significantly different to normal residential compartments. Informal settlement dwellings frequently have thermally thin and leaky boundaries. Due to the unique design of these compartments, detailed experimental studies were conducted to understand their fire dynamics. This paper presents the ability of FDS to model these under-ventilated steel sheeted fire tests. Four compartment fire tests were modelled with different wall boundary conditions, namely sealed walls (no leakage), non-sealed walls (leaky), leaky walls with cardboard lining, and highly insulated walls; with wood cribs as fuel and ISO-9705 room dimensions. FDS managed to capture the main fire dynamics and trends both qualitatively and quantitatively. However, using a cell size of 6 cm, the ability of FDS to accurately model the combustion at locations with high turbulent flows (using the infinitely fast chemistry mixing controlled combustion model), and the effect of leakage, was relatively poor and both factors should be further studied with finer LES filter width. Using the validated FDS models, new flashover criteria for thermally thin compartments were defined as a combination of critical hot gas layer and wall temperatures. Additionally, a parametric study was conducted to propose an empirical correlation to estimate the onset Heat Release Rate required for flashover, as current knowledge fails to account properly for large scale compartments with thermally thin boundaries. The empirical correlation is demonstrated to have an accuracy of ≈ ± 10% compared with the FDS models
    • …
    corecore