11 research outputs found

    New approach to the conceptual design of STUMM: A module dedicated to the monitoring of neutron and gamma radiation fields generated in IFMIF-DONES

    Get PDF
    International Fusion Materials Irradiation Facility — DEMOsingle bondOriented Neutron Source (IFMIF-DONES) is a planned powerful neutron source, which will generate an intense flux of neutrons (up to ∼1015n/s/cm2) with a fusion-relevant energy spectrum. It will be an accelerator source based on deuteron beam - lithium target reactions. The engineering design of IFMIF-DONES is elaborated in the frame of the Early Neutron Source work package of the EUROfusion consortium. The facility will be dedicated to the irradiation of suitable structural materials planned for the construction of future fusion reactors such as DEMO (Demonstration Fusion Power Plant). Start-up Monitoring Module (STUMM) is designed to monitor radiation and thermal conditions during the commissioning phase of IFMIF-DONES, characterize the produced neutron flux and validate neutronic modeling of the facility. The conceptual design of STUMM is prepared by a team of physicists and engineers from the Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN) and the National Centre for Nuclear Research (NCBJ), Poland. This paper presents the concept of STUMM, the proposed design of the module, and selected measuring systems

    The T2K Side Muon Range Detector

    Full text link
    The T2K experiment is a long baseline neutrino oscillation experiment aiming to observe the appearance of {\nu} e in a {\nu}{\mu} beam. The {\nu}{\mu} beam is produced at the Japan Proton Accelerator Research Complex (J-PARC), observed with the 295 km distant Super- Kamiokande Detector and monitored by a suite of near detectors at 280m from the proton target. The near detectors include a magnetized off-axis detector (ND280) which measures the un-oscillated neutrino flux and neutrino cross sections. The present paper describes the outermost component of ND280 which is a side muon range detector (SMRD) composed of scintillation counters with embedded wavelength shifting fibers and Multi-Pixel Photon Counter read-out. The components, performance and response of the SMRD are presented.Comment: 13 pages, 19 figures v2: fixed several typos; fixed reference

    The SMRD subdetector at the T2K near detector station

    Get PDF
    The T2K long-baseline neutrino oscillation experiment is running in Japan. The primary goals of the T2K are measurement of the mixing angle 13, and precise measurements of the mixing angle 23 and of the mass difference m2 23. The installation of the near detector complex was completed and first data were already registered. This article presents operation of the Side Muon Range Detector, a component of the Off-Axis near detector. Detector concept and implementation are presented, followed by a description of cosmic muon track reconstruction algorithm and finally current status

    The SST-1M project for the Cherenkov Telescope Array

    Get PDF
    The SST-1M project, run by a Consortium of institutes from Czech Republic, Poland and Switzerland, has been proposed as a solution for implementing the small-size telescope array of the southern site of the Cherenkov Telescope Array. The technology is a pathfinder for efficient production of cost-effective imaging air Cherenkov telescopes. We report on the main system features and recent upgrades, the performances validation and the operation campaign carried out in 2018

    The analysis of oral nutritional supplements related aspects among patients with digestive system cancer

    Get PDF
    OBJECTIVE: Malnutrition-related disease particularly occur in patients with digestive system cancer. The administration of oral nutritional supplements (ONSs) is one of the methods of nutritional support recommended for oncological patients. The primary aim of this study was to assess the consumption-related aspects of ONSs among patients with digestive system cancer. The secondary aim was to assess the impact of ONSs consumption on the quality of life of these patients. PATIENTS AND METHODS: The current study included 69 patients with digestive system cancer. The assessment of ONSs-related aspects among cancer patients was conducted using a self-designed questionnaire, which has been accepted by Independent Bioethics Committee. RESULTS: Among all patients, 65% of participants declared that they consumed ONSs. Patients consumed various types of ONSs. However, the most common were protein products (40%) and standard products (37.78%). Only 4.44% of patients consumed products with immunomodulatory ingredients. Nausea was the most commonly (15.56%) observed side effect after ONSs consumption. Considering particular types of ONSs, side effects were the most commonly declared by patients who consumed standard products (p=0.157). The easy product availability in the pharmacy was noted by 80% of participants. However, 48.89% of patients assessed the cost of ONSs as not acceptable (48.89%). 46.67% of studied patients did not observe the improvement of quality of life after ONSs consumption. CONCLUSIONS: We have demonstrated that patients with digestive system cancer consumed various period, amount, and types of ONSs. Side effects after ONSs consumption occur rarely. However, the improvement of quality of life related to ONSs consumption was not noted in almost half of participants. ONSs are easily available in pharmacy

    Microbiota-derived metabolites in colorectal cancer patients in preoperative period

    Get PDF
    OBJECTIVE: Short-chain fatty acids (SCFAs) are microbial derived metabolites, which have multiple beneficial properties. The amount of SCFAs depends on several factors, such as age, diet (mainly intake of dietary fiber), and overall health condition. The normal proportion between SCFAs is 3:1:1 for acetate, proprionate and butyrate, respectively. In colorectal cancer (CRC) patients, microbiota alterations have been shown. Consequently, metabolome within the gut might change to a large extent. Therefore, the aim of this study was to analyse the content of SCFAs and the proportion between SCFAs in the stool obtained from CRC patients in preoperative period. PATIENTS AND METHODS: This study included 15 patients with CRC in preoperative period. The stool samples were taken and stored at -80°C in the Fahrenheit Biobank BBMRI.pl, Medical University of Gdansk, Poland. The analysis of SCFAs from stool samples was conducted by means of gas chromatography. RESULTS: This study included mainly males (66.67%, n=10). In all patients, there was abnormal proportion between SCFAs. The extremely higher concentration of butyrate was noted in 2 samples (13.33%) compared to the rest of patients. However, based on normal proportion between SCFAs, the results <1 for butyrate were noted in 93.33% of patients. CONCLUSIONS: SCFAs pool is altered in CRC patients, among others characterized by low level of butyrate. It should be considered to administer butyrate supplementation to CRC patients especially prior to surgery to support an appropriate preparation to this treatment

    Preliminary design of the COMPASS upgrade tokamak

    Get PDF
    COMPASS Upgrade is a new medium size, high magnetic field tokamak (R = 0.9 m, Bt = 5 T, Ip = 2 MA) currently under design in the Czech Republic. It will provide unique capabilities for addressing some of the key challenges in plasma exhaust physics, advanced confinement modes and advanced plasma configurations as well as testing new plasma facing materials and liquid metal divertor concepts. This paper contains an overview of the preliminary engineering design of the main systems of the COMPASS Upgrade tokamak (vacuum vessel, central solenoid and poloidal field coils, toroidal field coils, support structure, cryostat, cryogenic system, power supply system and machine monitoring and protection system). The description of foreseen auxiliary plasma heating systems and plasma diagnostics is also provided as well as a summary of expected plasma performance and available plasma configurations
    corecore