68,197 research outputs found
A high-level 3D visualization API for Java and ImageJ
BACKGROUND: Current imaging methods such as Magnetic Resonance Imaging (MRI), Confocal microscopy, Electron Microscopy (EM) or Selective Plane Illumination Microscopy (SPIM) yield three-dimensional (3D) data sets in need of appropriate computational methods for their analysis. The reconstruction, segmentation and registration are best approached from the 3D representation of the data set.
RESULTS: Here we present a platform-independent framework based on Java and Java 3D for accelerated rendering of biological images. Our framework is seamlessly integrated into ImageJ, a free image processing package with a vast collection of community-developed biological image analysis tools. Our framework enriches the ImageJ software libraries with methods that greatly reduce the complexity of developing image analysis tools in an interactive 3D visualization environment. In particular, we provide high-level access to volume rendering, volume editing, surface extraction, and image annotation. The ability to rely on a library that removes the low-level details enables concentrating software development efforts on the algorithm implementation parts.
CONCLUSIONS: Our framework enables biomedical image software development to be built with 3D visualization capabilities with very little effort. We offer the source code and convenient binary packages along with extensive documentation at http://3dviewer.neurofly.de
In vivo volumetric imaging of human retinal circulation with phase-variance optical coherence tomography
We present in vivo volumetric images of human retinal micro-circulation using Fourier-domain optical coherence tomography (Fd-OCT) with the phase-variance based motion contrast method. Currently fundus fluorescein angiography (FA) is the standard technique in clinical settings for visualizing blood circulation of the retina. High contrast imaging of retinal vasculature is achieved by injection of a fluorescein dye into the systemic circulation. We previously reported phase-variance optical coherence tomography (pvOCT) as an alternative and non-invasive technique to image human retinal capillaries. In contrast to FA, pvOCT allows not only noninvasive visualization of a two-dimensional retinal perfusion map but also volumetric morphology of retinal microvasculature with high sensitivity. In this paper we report high-speed acquisition at 125 kHz A-scans with pvOCT to reduce motion artifacts and increase the scanning area when compared with previous reports. Two scanning schemes with different sampling densities and scanning areas are evaluated to find optimal parameters for high acquisition speed in vivo imaging. In order to evaluate this technique, we compare pvOCT capillary imaging at 3x3 mm^2 and 1.5x1.5 mm^2 with fundus FA for a normal human subject. Additionally, a volumetric view of retinal capillaries and a stitched image acquired with ten 3x3 mm^2 pvOCT sub-volumes are presented. Visualization of retinal vasculature with pvOCT has potential for diagnosis of retinal vascular diseases
Look & Listen: Sonification and Visualization of Multiparameter Micrographs
Nattkemper TW, Hermann T, Schubert W, Ritter H. Look & Listen: Sonification and Visualization of Multiparameter Micrographs. In: Engineering in Medicine and Biology Society. Proceedings of the 25th Annual International Conference of the IEEE. Vol 2. Cancun, Mexico: IEEE; 2003: 1311-1314.Multiparameter imaging techniques provide large numbers of high-dimensional image data in modern biomedical research. Besides algorithms for image registration, normalization and segmentation, new methods for interactive data exploration must be proposed and evaluated. We propose a new approach for auditory data representation, based on sonification. The approach is applied to a multiparameter image data set, generated with immunofluorescence techniques and compared to a conventional visualization approach and to a combination of both. For comparison, a psychophysical experiment was conducted, in which one standard evaluation procedure is modeled. Our results show, that all three approaches lead to comparable evaluation accuracies for all subjects. We conclude, that both, acoustical and visual approaches can be combined to display data sets of large dimensionality
Using high resolution displays for high resolution cardiac data
The ability to perform fast, accurate, high resolution visualization is fundamental
to improving our understanding of anatomical data. As the volumes of data
increase from improvements in scanning technology, the methods applied to rendering
and visualization must evolve. In this paper we address the interactive display of
data from high resolution MRI scanning of a rabbit heart and subsequent histological
imaging. We describe a visualization environment involving a tiled LCD panel
display wall and associated software which provide an interactive and intuitive user
interface.
The oView software is an OpenGL application which is written for the VRJuggler
environment. This environment abstracts displays and devices away from the
application itself, aiding portability between different systems, from desktop PCs to
multi-tiled display walls. Portability between display walls has been demonstrated
through its use on walls at both Leeds and Oxford Universities. We discuss important
factors to be considered for interactive 2D display of large 3D datasets,
including the use of intuitive input devices and level of detail aspects
Veni Vidi Vici, A Three-Phase Scenario For Parameter Space Analysis in Image Analysis and Visualization
Automatic analysis of the enormous sets of images is a critical task in life
sciences. This faces many challenges such as: algorithms are highly
parameterized, significant human input is intertwined, and lacking a standard
meta-visualization approach. This paper proposes an alternative iterative
approach for optimizing input parameters, saving time by minimizing the user
involvement, and allowing for understanding the workflow of algorithms and
discovering new ones. The main focus is on developing an interactive
visualization technique that enables users to analyze the relationships between
sampled input parameters and corresponding output. This technique is
implemented as a prototype called Veni Vidi Vici, or "I came, I saw, I
conquered." This strategy is inspired by the mathematical formulas of numbering
computable functions and is developed atop ImageJ, a scientific image
processing program. A case study is presented to investigate the proposed
framework. Finally, the paper explores some potential future issues in the
application of the proposed approach in parameter space analysis in
visualization
Logarithmic intensity and speckle-based motion contrast methods for human retinal vasculature visualization using swept source optical coherence tomography
We formulate a theory to show that the statistics of OCT signal amplitude and intensity are highly dependent on the sample reflectivity strength, motion, and noise power. Our theoretical and experimental results depict the lack of speckle amplitude and intensity contrasts to differentiate regions of motion from static areas. Two logarithmic intensity-based contrasts, logarithmic intensity variance (LOGIV) and differential logarithmic intensity variance (DLOGIV), are proposed for serving as surrogate markers for motion with enhanced sensitivity. Our findings demonstrate a good agreement between the theoretical and experimental results for logarithmic intensity-based contrasts. Logarithmic intensity-based motion and speckle-based contrast methods are validated and compared for in vivo human retinal vasculature visualization using high-speed swept-source optical coherence tomography (SS-OCT) at 1060 nm. The vasculature was identified as regions of motion by creating LOGIV and DLOGIV tomograms: multiple B-scans were collected of individual slices through the retina and the variance of logarithmic intensities and differences of logarithmic intensities were calculated. Both methods captured the small vessels and the meshwork of capillaries associated with the inner retina in en face images over 4 mm^2 in a normal subject
- …