65 research outputs found

    A Multi-Dataset Characterization of Window-based Hyperparameters for Deep CNN-driven sEMG Pattern Recognition

    Get PDF
    The control performance of myoelectric prostheses would not only depend on the feature extraction and classification algorithms but also on interactions of dynamic window-based hyper-parameters (WBHP) used to construct input signals. However, the relationship between these hyper-parameters and how they influence the performance of the convolutional neural networks (CNNs) during motor intent decoding has not been studied. Therefore, we investigated the impact of various combinations of WBHP (window length and overlap) employed for the construction of raw 2-dimensional (2D) surface electromyogram signals on the performance of CNNs when used for motion intent decoding. Moreover, we examined the relationship between the window length of the 2D sEMG and three commonly used CNN kernel sizes. To ensure high confidence in the findings, we implemented three CNNs which are variants of the existing models, and a newly proposed CNN model. Experimental analysis was conducted using three distinct benchmark databases, two from upper limb amputees and one from able-bodied subjects. The results demonstrate that the performance of the CNNs improved as the overlap between consecutively generated 2D signals increased, with 75% overlap yielding the optimal improvement by 12.62% accuracy and 39.60% F1-score compared to no overlap. Moreover, the CNNs performance was better for kernel size of seven than three and five across the databases. For the first time, we have established with multiple evidence that WBHP would substantially impact the decoding outcome and computational complexity of deep neural networks, and we anticipate that this may spur positive advancement in myoelectric control and related fields

    On the Utility of Representation Learning Algorithms for Myoelectric Interfacing

    Get PDF
    Electrical activity produced by muscles during voluntary movement is a reflection of the firing patterns of relevant motor neurons and, by extension, the latent motor intent driving the movement. Once transduced via electromyography (EMG) and converted into digital form, this activity can be processed to provide an estimate of the original motor intent and is as such a feasible basis for non-invasive efferent neural interfacing. EMG-based motor intent decoding has so far received the most attention in the field of upper-limb prosthetics, where alternative means of interfacing are scarce and the utility of better control apparent. Whereas myoelectric prostheses have been available since the 1960s, available EMG control interfaces still lag behind the mechanical capabilities of the artificial limbs they are intended to steer—a gap at least partially due to limitations in current methods for translating EMG into appropriate motion commands. As the relationship between EMG signals and concurrent effector kinematics is highly non-linear and apparently stochastic, finding ways to accurately extract and combine relevant information from across electrode sites is still an active area of inquiry.This dissertation comprises an introduction and eight papers that explore issues afflicting the status quo of myoelectric decoding and possible solutions, all related through their use of learning algorithms and deep Artificial Neural Network (ANN) models. Paper I presents a Convolutional Neural Network (CNN) for multi-label movement decoding of high-density surface EMG (HD-sEMG) signals. Inspired by the successful use of CNNs in Paper I and the work of others, Paper II presents a method for automatic design of CNN architectures for use in myocontrol. Paper III introduces an ANN architecture with an appertaining training framework from which simultaneous and proportional control emerges. Paper Iv introduce a dataset of HD-sEMG signals for use with learning algorithms. Paper v applies a Recurrent Neural Network (RNN) model to decode finger forces from intramuscular EMG. Paper vI introduces a Transformer model for myoelectric interfacing that do not need additional training data to function with previously unseen users. Paper vII compares the performance of a Long Short-Term Memory (LSTM) network to that of classical pattern recognition algorithms. Lastly, paper vIII describes a framework for synthesizing EMG from multi-articulate gestures intended to reduce training burden

    Bioelectrical signal processing in cardiac and neurological applications and electromyography: physiology, engineering, and noninvasive applications

    Get PDF
    The present article reviews two recent books dealing with rather closely related subjects; in fact, they tend to complement and supplement reciprocally. Obviously, the electromyogram is a bioelectrical signal that often is mathematically manipulated in different ways to better extract its information. Moreover, its correlation with other bioelectric variables may become necessary

    Sistema de miografia óptica para reconhecimento de gestos e posturas de mão

    Get PDF
    Orientador: Éric FujiwaraDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia MecânicaResumo: Nesse projeto, demonstrou-se um sistema de miografia óptica como uma alternativa promissora para monitorar as posturas da mão e os gestos do usuário. Essa técnica se fundamenta em acompanhar as atividades musculares responsáveis pelos movimentos da mão com uma câmera externa, relacionando a distorção visual verificada no antebraço com a contração e o relaxamento necessários para dada postura. Três configurações de sensores foram propostas, estudadas e avaliadas. A primeira propôs monitorar a atividade muscular analisando a variação da frequência espacial de uma textura de listras uniformes impressa sobre a pele, enquanto que a segunda se caracteriza pela contagem de pixels de pele visível dentro da região de interesse. Ambas as configurações se mostraram inviáveis pela baixa robustez e alta demanda por condições experimentais controladas. Por fim, a terceira recupera o estado da mão acompanhando o deslocamento de uma série de marcadores coloridos distribuídos ao longo do antebraço. Com um webcam de 24 fps e 640 × 480 pixels, essa última configuração foi validada para oito posturas distintas, explorando principalmente a flexão e extensão dos dedos e do polegar, além da adução e abdução do último. Os dados experimentais, adquiridos off-line, são submetidos a uma rotina de processamento de imagens para extrair a informação espacial e de cor dos marcadores em cada quadro, dados esses utilizados para rastrear os mesmos marcadores ao longo de todos os quadros. Para reduzir a influência das vibrações naturais e inerentes ao corpo humano, um sistema de referencial local é ainda adotado dentro da própria região de interesse. Finalmente, os dados quadro a quadro com o ground truth são alimentados a uma rede neural artificial sequencial, responsável pela calibração supervisionada do sensor e posterior classificação das posturas. O desempenho do sistema para a classificação das oito posturas foi avaliado com base na validação cruzada com 10-folds, com a câmera monitorando o antebraço pela superfície interna ou externa. O sensor apresentou uma precisão de ?92.4% e exatidão de ?97.9% para o primeiro caso, e uma precisão de ?75.1% e exatidão de ?92.5% para o segundo, sendo comparável a outras técnicas de miografia, demonstrando a viabilidade do projeto e abrindo perspectivas para aplicações em interfaces humano-robôAbstract: In this work, an optical myography system is demonstrated as a promising alternative to monitor hand posture and gestures of the user. This technique is based on accompanying muscular activities responsible for hand motion with an external camera, and relating the visual deformation observed on the forearm to the muscular contractions/relaxations for a given posture. Three sensor designs were proposed, studied and evaluated. The first one intended to monitor muscular activity by analyzing the spatial frequency variation of a uniformly distributed stripe pattern stamped on the skin, whereas the second one is characterized by reckoning visible skin pixels inside the region of interest. Both designs are impracticable due to their low robustness and high demand for controlled experimental conditions. At last, the third design retrieves hand configuration by tracking visually the displacements of a series of color markers distributed over the forearm. With a webcam of 24 fps and 640 × 480 pixels, this design was validated for eight different postures, exploring fingers and thumb flexion/extension, plus thumb adduction/abduction. The experimental data are acquired offline and, then, submitted to an image processing routine to extract color and spatial information of the markers in each frame; the extracted data is subsequently used to track the same markers along all frames. To reduce the influence of human body natural and inherent vibrations, a local reference frame is yet adopted in the region of interest. Finally, the frame by frame data, along with the ground truth posture, are fed into a sequential artificial neural network, responsible for sensor supervised calibration and subsequent posture classification. The system performance was evaluated in terms of eight postures classification via 10-fold cross-validation, with the camera monitoring either the underside or the back of the forearm. The sensor presented a ?92.4% precision and ?97.9% accuracy for the former, and a ?75.1% precision and ?92.5% accuracy for the latter, being thus comparable to other myographic techniques; it also demonstrated that the project is feasible and offers prospects for human-robot interaction applicationsMestradoEngenharia MecanicaMestre em Engenharia Mecânica33003017CAPE

    Multi-Day Analysis of Surface and Intramuscular EMG for Prosthetic Control

    Get PDF

    Robust and reliable hand gesture recognition for myoelectric control

    Get PDF
    Surface Electromyography (sEMG) is a physiological signal to record the electrical activity of muscles by electrodes applied to the skin. In the context of Muscle Computer Interaction (MCI), systems are controlled by transforming myoelectric signals into interaction commands that convey the intent of user movement, mostly for rehabilitation purposes. Taking the myoeletric hand prosthetic control as an example, using sEMG recorded from the remaining muscles of the stump can be considered as the most natural way for amputees who lose their limbs to perform activities of daily living with the aid of prostheses. Although the earliest myoelectric control research can date back to the 1950s, there still exist considerable challenges to address the significant gap between academic research and industrial applications. Most recently, pattern recognition-based control is being developed rapidly to improve the dexterity of myoelectric prosthetic devices due to the recent development of machine learning and deep learning techniques. It is clear that the performance of Hand Gesture Recognition (HGR) plays an essential role in pattern recognition-based control systems. However, in reality, the tremendous success in achieving very high sEMG-based HGR accuracy (≥ 90%) reported in scientific articles produced only limited clinical or commercial impact. As many have reported, its real-time performance tends to degrade significantly as a result of many confounding factors, such as electrode shift, sweating, fatigue, and day-to-day variation. The main interest of the present thesis is, therefore, to improve the robustness of sEMG-based HGR by taking advantage of the most recent advanced deep learning techniques to address several practical concerns. Furthermore, the challenge of this research problem has been reinforced by only considering using raw sparse multichannel sEMG signals as input. Firstly, a framework for designing an uncertainty-aware sEMG-based hand gesture classifier is proposed. Applying it allows us to quickly build a model with the ability to make its inference along with explainable quantified multidimensional uncertainties. This addresses the black-box concern of the HGR process directly. Secondly, to fill the gap of lacking consensus on the definition of model reliability in this field, a proper definition of model reliability is proposed. Based on it, reliability analysis can be performed as a new dimension of evaluation to help select the best model without relying only on classification accuracy. Our extensive experimental results have shown the efficiency of the proposed reliability analysis, which encourages researchers to use it as a supplementary tool for model evaluation. Next, an uncertainty-aware model is designed based on the proposed framework to address the low robustness of hand grasp recognition. This offers an opportunity to investigate whether reliable models can achieve robust performance. The results show that the proposed model can improve the long-term robustness of hand grasp recognition by rejecting highly uncertain predictions. Finally, a simple but effective normalisation approach is proposed to improve the robustness of inter-subject HGR, thus addressing the clinical challenge of having only a limited amount of data from any individual. The comparison results show that better performance can be obtained by it compared to a state-of-the-art (SoA) transfer learning method when only one training cycle is available. In summary, this study presents promising methods to pursue an accurate, robust, and reliable classifier, which is the overarching goal for sEMG-based HGR. The direction for future work would be the inclusion of these in real-time myoelectric control applications

    Towards Natural Control of Artificial Limbs

    Get PDF
    The use of implantable electrodes has been long thought as the solution for a more natural control of artificial limbs, as these offer access to long-term stable and physiologically appropriate sources of control, as well as the possibility to elicit appropriate sensory feedback via neurostimulation. Although these ideas have been explored since the 1960’s, the lack of a long-term stable human-machine interface has prevented the utilization of even the simplest implanted electrodes in clinically viable limb prostheses.In this thesis, a novel human-machine interface for bidirectional communication between implanted electrodes and the artificial limb was developed and clinically implemented. The long-term stability was achieved via osseointegration, which has been shown to provide stable skeletal attachment. By enhancing this technology as a communication gateway, the longest clinical implementation of prosthetic control sourced by implanted electrodes has been achieved, as well as the first in modern times. The first recipient has used it uninterruptedly in daily and professional activities for over one year. Prosthetic control was found to improve in resolution while requiring less muscular effort, as well as to be resilient to motion artifacts, limb position, and environmental conditions.In order to support this work, the literature was reviewed in search of reliable and safe neuromuscular electrodes that could be immediately used in humans. Additional work was conducted to improve the signal-to-noise ratio and increase the amount of information retrievable from extraneural recordings. Different signal processing and pattern recognition algorithms were investigated and further developed towards real-time and simultaneous prediction of limb movements. These algorithms were used to demonstrate that higher functionality could be restored by intuitive control of distal joints, and that such control remains viable over time when using epimysial electrodes. Lastly, the long-term viability of direct nerve stimulation to produce intuitive sensory feedback was also demonstrated.The possibility to permanently and reliably access implanted electrodes, thus making them viable for prosthetic control, is potentially the main contribution of this work. Furthermore, the opportunity to chronically record and stimulate the neuromuscular system offers new venues for the prediction of complex limb motions and increased understanding of somatosensory perception. Therefore, the technology developed here, combining stable attachment with permanent and reliable human-machine communication, is considered by the author as a critical step towards more functional artificial limbs

    Towards electrodeless EMG linear envelope signal recording for myo-activated prostheses control

    Get PDF
    After amputation, the residual muscles of the limb may function in a normal way, enabling the electromyogram (EMG) signals recorded from them to be used to drive a replacement limb. These replacement limbs are called myoelectric prosthesis. The prostheses that use EMG have always been the first choice for both clinicians and engineers. Unfortunately, due to the many drawbacks of EMG (e.g. skin preparation, electromagnetic interferences, high sample rate, etc.); researchers have aspired to find suitable alternatives. One proposes the dry-contact, low-cost sensor based on a force-sensitive resistor (FSR) as a valid alternative which instead of detecting electrical events, detects mechanical events of muscle. FSR sensor is placed on the skin through a hard, circular base to sense the muscle contraction and to acquire the signal. Similarly, to reduce the output drift (resistance) caused by FSR edges (creep) and to maintain the FSR sensitivity over a wide input force range, signal conditioning (Voltage output proportional to force) is implemented. This FSR signal acquired using FSR sensor can be used directly to replace the EMG linear envelope (an important control signal in prosthetics applications). To find the best FSR position(s) to replace a single EMG lead, the simultaneous recording of EMG and FSR output is performed. Three FSRs are placed directly over the EMG electrodes, in the middle of the targeted muscle and then the individual (FSR1, FSR2 and FSR3) and combination of FSR (e.g. FSR1+FSR2, FSR2-FSR3) is evaluated. The experiment is performed on a small sample of five volunteer subjects. The result shows a high correlation (up to 0.94) between FSR output and EMG linear envelope. Consequently, the usage of the best FSR sensor position shows the ability of electrode less FSR-LE to proportionally control the prosthesis (3-D claw). Furthermore, FSR can be used to develop a universal programmable muscle signal sensor that can be suitable to control the myo-activated prosthesis

    AN INVESTIGATION OF ELECTROMYOGRAPHIC (EMG) CONTROL OF DEXTROUS HAND PROSTHESES FOR TRANSRADIAL AMPUTEES

    Get PDF
    In reference to IEEE copyrighted material which is used with permission in this thesis, the IEEE does not endorse any of Plymouth University's products or services.There are many amputees around the world who have lost a limb through conflict, disease or an accident. Upper-limb prostheses controlled using surface Electromyography (sEMG) offer a solution to help the amputees; however, their functionality is limited by the small number of movements they can perform and their slow reaction times. Pattern recognition (PR)-based EMG control has been proposed to improve the functional performance of prostheses. It is a very promising approach, offering intuitive control, fast reaction times and the ability to control a large number of degrees of freedom (DOF). However, prostheses controlled with PR systems are not available for everyday use by amputees, because there are many major challenges and practical problems that need to be addressed before clinical implementation is possible. These include lack of individual finger control, an impractically large number of EMG electrodes, and the lack of deployment protocols for EMG electrodes site selection and movement optimisation. Moreover, the inability of PR systems to handle multiple forces is a further practical problem that needs to be addressed. The main aim of this project is to investigate the research challenges mentioned above via non-invasive EMG signal acquisition, and to propose practical solutions to help amputees. In a series of experiments, the PR systems presented here were tested with EMG signals acquired from seven transradial amputees, which is unique to this project. Previous studies have been conducted using non-amputees. In this work, the challenges described are addressed and a new protocol is proposed that delivers a fast clinical deployment of multi-functional upper limb prostheses controlled by PR systems. Controlling finger movement is a step towards the restoration of lost human capabilities, and is psychologically important, as well as physically. A central thread running through this work is the assertion that no two amputees are the same, each suffering different injuries and retaining differing nerve and muscle structures. This work is very much about individualised healthcare, and aims to provide the best possible solution for each affected individual on a case-by-case basis. Therefore, the approach has been to optimise the solution (in terms of function and reliability) for each individual, as opposed to developing a generic solution, where performance is optimised against a test population. This work is unique, in that it contributes to improving the quality of life for each individual amputee by optimising function and reliability. The main four contributions of the thesis are as follows: 1- Individual finger control was achieved with high accuracy for a large number of finger movements, using six optimally placed sEMG channels. This was validated on EMG signals for ten non-amputee and six amputee subjects. Thumb movements were classified successfully with high accuracy for the first time. The outcome of this investigation will help to add more movements to the prosthesis, and reduce hardware and computational complexity. 2- A new subject-specific protocol for sEMG site selection and reliable movement subset optimisation, based on the amputee’s needs, has been proposed and validated on seven amputees. This protocol will help clinicians to perform an efficient and fast deployment of prostheses, by finding the optimal number and locations of EMG channels. It will also find a reliable subset of movements that can be achieved with high performance. 3- The relationship between the force of contraction and the statistics of EMG signals has been investigated, utilising an experimental design where visual feedback from a Myoelectric Control Interface (MCI) helped the participants to produce the correct level of force. Kurtosis values were found to decrease monotonically when the contraction level increased, thus indicating that kurtosis can be used to distinguish different forces of contractions. 4- The real practical problem of the degradation of classification performance as a result of the variation of force levels during daily use of the prosthesis has been investigated, and solved by proposing a training approach and the use of a robust feature extraction method, based on the spectrum. The recommendations of this investigation improve the practical robustness of prostheses controlled with PR systems and progress a step further towards clinical implementation and improving the quality of life of amputees. The project showed that PR systems achieved a reliable performance for a large number of amputees, taking into account real life issues such as individual finger control for high dexterity, the effect of force level variation, and optimisation of the movements and EMG channels for each individual amputee. The findings of this thesis showed that the PR systems need to be appropriately tuned before usage, such as training with multiple forces to help to reduce the effect of force variation, aiming to improve practical robustness, and also finding the optimal EMG channel for each amputee, to improve the PR system’s performance. The outcome of this research enables the implementation of PR systems in real prostheses that can be used by amputees.Ministry of Higher Education and Scientific Research and Baghdad University- Baghdad/Ira
    • …
    corecore