15,347 research outputs found
Assessing the Zone of Comfort in Stereoscopic Displays using EEG
The conflict between vergence (eye movement) and accommodation (crystalline
lens deformation) occurs in every stereoscopic display. It could cause
important stress outside the "zone of comfort", when stereoscopic effect is too
strong. This conflict has already been studied using questionnaires, during
viewing sessions of several minutes. The present pilot study describes an
experimental protocol which compares two different comfort conditions using
electroencephalography (EEG) over short viewing sequences. Analyses showed
significant differences both in event-related potentials (ERP) and in frequency
bands power. An uncomfortable stereoscopy correlates with a weaker negative
component and a delayed positive component in ERP. It also induces a power
decrease in the alpha band and increases in theta and beta bands. With fast
responses to stimuli, EEG is likely to enable the conception of adaptive
systems, which could tune the stereoscopic experience according to each viewer
Exploring Cognitive States: Methods for Detecting Physiological Temporal Fingerprints
Cognitive state detection and its relationship to observable physiologically telemetry has been utilized for many human-machine and human-cybernetic applications. This paper aims at understanding and addressing if there are unique psychophysiological patterns over time, a physiological temporal fingerprint, that is associated with specific cognitive states. This preliminary work involves commercial airline pilots completing experimental benchmark task inductions of three cognitive states: 1) Channelized Attention (CA); 2) High Workload (HW); and 3) Low Workload (LW). We approach this objective by modeling these "fingerprints" through the use of Hidden Markov Models and Entropy analysis to evaluate if the transitions over time are complex or rhythmic/predictable by nature. Our results indicate that cognitive states do have unique complexity of physiological sequences that are statistically different from other cognitive states. More specifically, CA has a significantly higher temporal psychophysiological complexity than HW and LW in EEG and ECG telemetry signals. With regards to respiration telemetry, CA has a lower temporal psychophysiological complexity than HW and LW. Through our preliminary work, addressing this unique underpinning can inform whether these underlying dynamics can be utilized to understand how humans transition between cognitive states and for improved detection of cognitive states
Change blindness: eradication of gestalt strategies
Arrays of eight, texture-defined rectangles were used as stimuli in a one-shot change blindness (CB) task where there was a 50% chance that one rectangle would change orientation between two successive presentations separated by an interval. CB was eliminated by cueing the target rectangle in the first stimulus, reduced by cueing in the interval and unaffected by cueing in the second presentation. This supports the idea that a representation was formed that persisted through the interval before being 'overwritten' by the second presentation (Landman et al, 2003 Vision Research 43149–164]. Another possibility is that participants used some kind of grouping or Gestalt strategy. To test this we changed the spatial position of the rectangles in the second presentation by shifting them along imaginary spokes (by ±1 degree) emanating from the central fixation point. There was no significant difference seen in performance between this and the standard task [F(1,4)=2.565, p=0.185]. This may suggest two things: (i) Gestalt grouping is not used as a strategy in these tasks, and (ii) it gives further weight to the argument that objects may be stored and retrieved from a pre-attentional store during this task
Bacteria Hunt: Evaluating multi-paradigm BCI interaction
The multimodal, multi-paradigm brain-computer interfacing (BCI) game Bacteria Hunt was used to evaluate two aspects of BCI interaction in a gaming context. One goal was to examine the effect of feedback on the ability of the user to manipulate his mental state of relaxation. This was done by having one condition in which the subject played the game with real feedback, and another with sham feedback. The feedback did not seem to affect the game experience (such as sense of control and tension) or the objective indicators of relaxation, alpha activity and heart rate. The results are discussed with regard to clinical neurofeedback studies. The second goal was to look into possible interactions between the two BCI paradigms used in the game: steady-state visually-evoked potentials (SSVEP) as an indicator of concentration, and alpha activity as a measure of relaxation. SSVEP stimulation activates the cortex and can thus block the alpha rhythm. Despite this effect, subjects were able to keep their alpha power up, in compliance with the instructed relaxation task. In addition to the main goals, a new SSVEP detection algorithm was developed and evaluated
Brain Control of Movement Execution Onset Using Local Field Potentials in Posterior Parietal Cortex
The precise control of movement execution onset is essential for safe and autonomous cortical motor prosthetics. A recent study from the parietal reach region (PRR) suggested that the local field potentials (LFPs) in this area might be useful for decoding execution time information because of the striking difference in the LFP spectrum between the plan and execution states (Scherberger et al., 2005). More specifically, the LFP power in the 0–10 Hz band sharply rises while the power in the 20–40 Hz band falls as the state transitions from plan to execution. However, a change of visual stimulus immediately preceded reach onset, raising the possibility that the observed spectral change reflected the visual event instead of the reach onset. Here, we tested this possibility and found that the LFP spectrum change was still time locked to the movement onset in the absence of a visual event in self-paced reaches. Furthermore, we successfully trained the macaque subjects to use the LFP spectrum change as a "go" signal in a closed-loop brain-control task in which the animals only modulated the LFP and did not execute a reach. The execution onset was signaled by the change in the LFP spectrum while the target position of the cursor was controlled by the spike firing rates recorded from the same site. The results corroborate that the LFP spectrum change in PRR is a robust indicator for the movement onset and can be used for control of execution onset in a cortical prosthesis
Data-driven multivariate and multiscale methods for brain computer interface
This thesis focuses on the development of data-driven multivariate and multiscale methods
for brain computer interface (BCI) systems. The electroencephalogram (EEG), the
most convenient means to measure neurophysiological activity due to its noninvasive nature,
is mainly considered. The nonlinearity and nonstationarity inherent in EEG and its
multichannel recording nature require a new set of data-driven multivariate techniques to
estimate more accurately features for enhanced BCI operation. Also, a long term goal
is to enable an alternative EEG recording strategy for achieving long-term and portable
monitoring.
Empirical mode decomposition (EMD) and local mean decomposition (LMD), fully
data-driven adaptive tools, are considered to decompose the nonlinear and nonstationary
EEG signal into a set of components which are highly localised in time and frequency. It
is shown that the complex and multivariate extensions of EMD, which can exploit common
oscillatory modes within multivariate (multichannel) data, can be used to accurately
estimate and compare the amplitude and phase information among multiple sources, a
key for the feature extraction of BCI system. A complex extension of local mean decomposition
is also introduced and its operation is illustrated on two channel neuronal
spike streams. Common spatial pattern (CSP), a standard feature extraction technique
for BCI application, is also extended to complex domain using the augmented complex
statistics. Depending on the circularity/noncircularity of a complex signal, one of the
complex CSP algorithms can be chosen to produce the best classification performance
between two different EEG classes.
Using these complex and multivariate algorithms, two cognitive brain studies are
investigated for more natural and intuitive design of advanced BCI systems. Firstly, a Yarbus-style auditory selective attention experiment is introduced to measure the user
attention to a sound source among a mixture of sound stimuli, which is aimed at improving
the usefulness of hearing instruments such as hearing aid. Secondly, emotion experiments
elicited by taste and taste recall are examined to determine the pleasure and displeasure
of a food for the implementation of affective computing. The separation between two
emotional responses is examined using real and complex-valued common spatial pattern
methods.
Finally, we introduce a novel approach to brain monitoring based on EEG recordings
from within the ear canal, embedded on a custom made hearing aid earplug. The new
platform promises the possibility of both short- and long-term continuous use for standard
brain monitoring and interfacing applications
EEG in the classroom: Synchronised neural recordings during video presentation
We performed simultaneous recordings of electroencephalography (EEG) from
multiple students in a classroom, and measured the inter-subject correlation
(ISC) of activity evoked by a common video stimulus. The neural reliability, as
quantified by ISC, has been linked to engagement and attentional modulation in
earlier studies that used high-grade equipment in laboratory settings. Here we
reproduce many of the results from these studies using portable low-cost
equipment, focusing on the robustness of using ISC for subjects experiencing
naturalistic stimuli. The present data shows that stimulus-evoked neural
responses, known to be modulated by attention, can be tracked in for groups of
students with synchronized EEG acquisition. This is a step towards real-time
inference of engagement in the classroom.Comment: 14 pages, 5 figures, 3 tables. Preprint version. Revision of original
preprint. Supplementary materials added as ancillary fil
- …