25,135 research outputs found

    Comparative analysis of AC and DC distribution system with respect to harmonic distortion considering daily load profile

    Get PDF
    Electrical energy is the most efficient and the cleanest form of energy at the moment that is being transmitted and distributed amongst end-users. From its earlier days, the AC system was preferred as an economical solution for transmission and distribution. However, the development in the power electronics technology and the evolution of highly efficient power electronic converters have established the resurgence of DC power system. Furthermore, the trend is shifting towards DC loads as various energy efficient appliances, such as DC inverter air conditioners, operate on DC nowadays. This further advocates the shift towards the DC power system. This research works is an effort to perform the comparative analysis of AC Distribution System (ACDS) and DC Distribution System (DCDS), with regards to power quality and harmonic distortion in particular. The comparison is performed considering load profile and load variation on daily basis. Simulations are performed in MATLAB. It has been concluded at the end that ACDS is better than DCDS in terms of power quality as total harmonic distortion of the DCDS under the same loading and same load variation during the whole day was significantly higher than that of ACDS

    SIMULASI RUGI-RUGI DAYA AKIBAT TOTAL HARMONIC DISTORTION (THD) TERHADAP EFISIENSI TRANSFORMATOR DAYA DI GARDU INDUK 150 KV BLORA

    Get PDF
    With the development of technology that develops in society, the need for electrical energy increases so that optimal and quality electrical energy is needed. One of the quality electrical energy comes from optimal distribution, but in its distribution there are often disturbances such as current imbalances caused by several factors, causing power losses. The use of non-linear loads on customers is one of the causes of power losses caused by the emergence of harmonic currents so that the sinusoidal waveform that is channeled becomes defective. Power loss can affect the level of distribution quality and decrease efficiency in power transformers in the 150 kV Blora substation. The development of today's technology world has created energy-efficient lighting such as Compact Fluorescent Lamps (CFL), however, the voltage and current harmonics generated by these loads can result in high power losses, therefore simulation and analysis of the power losses caused are required. by non-linear loads such as CFLs. Simulation of power losses caused by Total Harmonic Distortion (THD) on the efficiency of power transformers at PT PLN (Persero) 150 kV Blora substation using the ETAP 19.0.1 software. Based on the data obtained, it is then simulated to show a distorted waveform. The results of the simulation show that the THDi value at the 150 kV Blora substation does not meet SPLN D5.004-1: 2012, while the power loss caused by THD results in a decrease in the efficiency of the power transformer in the 150 kV Blora substation by up to 2,32%

    Power quality and electromagnetic compatibility: special report, session 2

    Get PDF
    The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems. Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages). The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks: Block 1: Electric and Magnetic Fields, EMC, Earthing systems Block 2: Harmonics Block 3: Voltage Variation Block 4: Power Quality Monitoring Two Round Tables will be organised: - Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13) - Reliability Benchmarking - why we should do it? What should be done in future? (RT 15

    Geometric Objects: A Quality Index to Electromagnetic Energy Transfer Performance in Sustainable Smart Buildings

    Get PDF
    Sustainable smart buildings play an essential role in terms of more efficient energy. However, these buildings as electric loads are affected by an important distortion in the current and voltage waveforms caused by the increasing proliferation of nonlinear electronic devices. Overall, buildings all around the world consume a significant amount of energy, which is about one-third of the total primary energy resources. Optimization of the power transfer process of such amount of energy is a crucial issue that needs specific tools to integrate energy-efficient behaviour throughout the grid. When nonlinear loads are present, new capable ways of thinking are needed to consider the effects of harmonics and related power components. In this manner, technology innovations are necessary to update the power factor concept to a generalized total or a true one, where different power components involved in it calculation, properly reflect each harmonic interaction. This work addresses an innovative theory that applies the Poynting Vector philosophy via Geometric Algebra to the electromagnetic energy transfer process providing a physical foundation. In this framework, it is possible to analyse and detect the nature of disturbing loads in the exponential growth of new globalized buildings and architectures in our era. This new insight is based on the concept of geometric objects with different dimension: vector, bivector, trivector, multivector. Within this paper, these objects are correlated with the electromagnetic quantities responsible for the energy flow supplied to the most common loads in sustainable smart buildings. Besides, it must be considered that these phenomena are characterized by a quality index multivector appropriate even for detecting harmonic sources. A numerical example is used to illustrate the clear capabilities of the suggested index when it applies to industrial loads for optimization of energy control systems and enhance comfort management in smart sustainable buildings

    Harmonic effects on induction and line start permanent magnet machines

    Get PDF
    Power Electronics (PE) are implemented in a wide variety of appliances, either to increase its controllability or energy efficiency, or simply because a DC supply is needed. The massive integration of rectifiers has resulted in a decrease of the supply voltage quality. Although PE have enabled the end user to control electrical machines, the resulting distortion inversely affects Direct On-Line (DOL) machines. In this paper a review is presented of the influence of these supply anomalies on Induction Motors (IM). The suggested problems have already been subject of much study. However, as new DOL technologies are emerging, for example Line Start Permanent Magnet Machines or Induction Generator systems, the influence of supply distortion on these systems should also be considered. This paper will present a comprehensive overview of the loss mechanisms, the magnitude of the losses and the impact of these losses on operation of IM, LSPMM and IG

    Plucked piezoelectric bimorphs for knee-joint energy harvesting: modelling and experimental validation

    Get PDF
    The modern drive towards mobility and wireless devices is motivating intensive research in energy harvesting technologies. To reduce the battery burden on people, we propose the adoption of a frequency up-conversion strategy for a new piezoelectric wearable energy harvester. Frequency up-conversion increases efficiency because the piezoelectric devices are permitted to vibrate at resonance even if the input excitation occurs at much lower frequency. Mechanical plucking-based frequency up-conversion is obtained by deflecting the piezoelectric bimorph via a plectrum, then rapidly releasing it so that it can vibrate unhindered; during the following oscillatory cycles, part of the mechanical energy is converted into electrical energy. In order to guide the design of such a harvester, we have modelled with finite element methods the response and power generation of a piezoelectric bimorph while it is plucked. The model permits the analysis of the effects of the speed of deflection as well as the prediction of the energy produced and its dependence on the electrical load. An experimental rig has been set up to observe the response of the bimorph in the harvester. A PZT-5H bimorph was used for the experiments. Measurements of tip velocity, voltage output and energy dissipated across a resistor are reported. Comparisons of the experimental results with the model predictions are very successful and prove the validity of the model

    Voltage harmonic reduction for randomly time-varying source characteristics and voltage harmonics

    Get PDF
    This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. Copyright @ 2006 IEEEPotential applications of probabilistic modeling of current and voltage harmonics concern many aspects of power system engineering as accurate prediction of power system harmonic behavior provides important information to utility companies and equipment designers. In this paper, a method of reducing the expected value of the total voltage harmonic distortion for a specified range of source impedance values at different buses by using LC compensators, where it is desired to maintain a given power factor at a specified value, is presented. The criterion is based on mean value estimation of source and load characteristics, which are enabled by sampling measurements performed on the examined electrical plant as well as statistical analysis

    A multifunctional dynamic voltage restorer for power quality improvement

    Get PDF
    Power quality is a major concern in electrical power systems. The power quality disturbances such as sags, swells, harmonic distortion and other interruptions have an impact on the electrical devices and machines and in severe cases can cause serious damages. Therefore it is necessary to recognize and compensate all types of disturbances at an earliest time to ensure normal and efficient operation of the power system. To solve these problems, many types of power devices are used. At the present time, one of those devices, Dynamic Voltage Restorer (DVR) is the most efficient and effective device used in power distribution systems. In this paper, design and modeling of a new structure and a new control method of multifunctional DVRs for voltage quality correction are presented. The new control method was built in the stationary frame by combining Proportional Resonant controllers and Sequence-Decouple Resonant controllers. The performance of the device and this method under different conditions such as voltage swell, voltage sag due to symmetrical and unsymmetrical short circuit, starting of motors, and voltage distortion are described. Simulation result show the superior capability of the proposed DVR to improve power quality under different operating conditions and the effectiveness of the proposed method. The proposed new DVR controller is able to detect the voltage disturbances and control the converter to inject appropriate voltages independently for each phase and compensate to load voltage through three single-phase transformers.Web of Science116art. no. 135

    Ancillary Services in Hybrid AC/DC Low Voltage Distribution Networks

    Get PDF
    In the last decade, distribution systems are experiencing a drastic transformation with the advent of new technologies. In fact, distribution networks are no longer passive systems, considering the current integration rates of new agents such as distributed generation, electrical vehicles and energy storage, which are greatly influencing the way these systems are operated. In addition, the intrinsic DC nature of these components, interfaced to the AC system through power electronics converters, is unlocking the possibility for new distribution topologies based on AC/DC networks. This paper analyzes the evolution of AC distribution systems, the advantages of AC/DC hybrid arrangements and the active role that the new distributed agents may play in the upcoming decarbonized paradigm by providing different ancillary services.Ministerio de Economía y Competitividad ENE2017-84813-RUnión Europea (Programa Horizonte 2020) 76409

    Geometric Algebra in Nonsinusoidal Power Systems: A Case of Study for Passive Compensation

    Get PDF
    New-generation power networks, such as microgrids, are being affected by the proliferation of nonlinear electronic systems, resulting in harmonic disturbances both in voltage and current that affect the symmetry of the system. This paper presents a method based on the application of geometric algebra (GA) to the resolution of power flow in nonsinusoidal single-phase electrical systems for the correct determination of its components to achieve passive compensation of true quadrature current. It is demonstrated that traditional techniques based on the concepts of Budeanu, Fryze or IEEE1459 fail to determine the interaction between voltage and current and therefore, are not suitable for being used as a basis for the compensation of nonactive power components. An example is included that demonstrates the superiority of GA method and is compared to previous work where GA approaches and traditional methods have also been used
    corecore