217 research outputs found

    Miniaturised Wireless Power Transfer Systems for Neurostimulation: A Review

    Get PDF
    In neurostimulation, wireless power transfer is an efficient technology to overcome several limitations affecting medical devices currently used in clinical practice. Several methods were developed over the years for wireless power transfer. In this review article, we report and discuss the three most relevant methodologies for extremely miniaturised implantable neurostimulator: ultrasound coupling, inductive coupling and capacitive coupling. For each powering method, the discussion starts describing the physical working principle. In particular, we focus on the challenges given by the miniaturisation of the implanted integrated circuits and the related ad-hoc solutions for wireless power transfer. Then, we present recent developments and progresses in wireless power transfer for biomedical applications. Last, we compare each technique based on key performance indicators to highlight the most relevant and innovative solutions suitable for neurostimulation, with the gaze turned towards miniaturisation

    Wireless Power Transfer Techniques for Implantable Medical Devices:A Review

    Get PDF
    Wireless power transfer (WPT) systems have become increasingly suitable solutions for the electrical powering of advanced multifunctional micro-electronic devices such as those found in current biomedical implants. The design and implementation of high power transfer efficiency WPT systems are, however, challenging. The size of the WPT system, the separation distance between the outside environment and location of the implanted medical device inside the body, the operating frequency and tissue safety due to power dissipation are key parameters to consider in the design of WPT systems. This article provides a systematic review of the wide range of WPT systems that have been investigated over the last two decades to improve overall system performance. The various strategies implemented to transfer wireless power in implantable medical devices (IMDs) were reviewed, which includes capacitive coupling, inductive coupling, magnetic resonance coupling and, more recently, acoustic and optical powering methods. The strengths and limitations of all these techniques are benchmarked against each other and particular emphasis is placed on comparing the implanted receiver size, the WPT distance, power transfer efficiency and tissue safety presented by the resulting systems. Necessary improvements and trends of each WPT techniques are also indicated per specific IMD

    Design, Fabrication, and Validation of a Highly Miniaturized Wirelessly Powered Neural Implant

    Get PDF
    We have recently witnessed an explosion in the number of neurons that can be recorded and/or stimulated simultaneously during neurophysiological experiments. Experiments have progressed from recording or stimulation with a single electrode to Micro-Electrode Array (MEA) such as the Utah Array. These MEAs can be instrumented with current drivers, neural amplifiers, digitizers and wireless communication links. The broad interest in these MEAs suggests that there is a need for large scale neural recording and stimulation. The ultimate goal is to coordinate the recordings and stimulation of potentially thousands of neurons from many brain areas. Unfortunately, current state-of-the-art MEAs are limited by their scalability and long-term stability because of their physical size and rigid configuration. Furthermore, some applications prioritize a distributed neural interface over one that offers high resolution. Examples of biomedical applications that necessitate an interface with neurons from many sites in the brain include: i) understanding and treating neurological disorders that affect distributed locations throughout the CNS; ii) revolutionizing our understanding of the brain by studying the correlations between neural networks from different regions of the brain and the mechanisms of cognitive functions; and iii) covering larger area in the sensorimotor cortex of amputees to more accurately control robotic prosthetic limbs or better evoke a sense of touch. One solution to make large scale, fully specifiable, electrical stimulation and recording possible, is to disconnect the electrodes from the base, so that they can be arbitrarily placed, using a syringe, freely in the nervous system. To overcome the challenges of system miniaturization, we propose the “microbead”, an ultra-small neural stimulating implant, that is currently implemented in a 130nm CMOS technology with the following characteristics: 200 μm × 200 μm × 80 μm size; optimized wireless powering, all micro-electronics on single chip; and integrated electrodes and coil. The stimulating microbead is validated in a sciatic nerve by generating leg movements. A recording microbead is also investigated with following characteristics: wireless powering using steerable phased coil array, miniaturized front-end, and backscattering telemetry. These microbeads could eventually replace the rigid arrays that are currently the state-of-the-art in electrophysiology set-ups

    A Multi-Dimensional Analysis of a Novel Approach for Wireless Stimulation

    Get PDF
    The elimination of integrated batteries in biomedical implants holds great promise for improving health outcomes in patients with implantable devices. However, despite extensive research in wireless power transfer, achieving efficient power transfer and effective operational range have remained a hindering challenge within anatomical constraints. Objective : We hereby demonstrate an intravascular wireless and batteryless microscale stimulator, designed for (1) low power dissipation via intermittent transmission and (2) reduced fixation mechanical burden via deployment to the anterior cardiac vein (ACV, ∼3.8 mm in diameter). Methods : We introduced a unique coil design circumferentially confined to a 3 mm diameter hollow-cylinder that was driven by a novel transmitter-based control architecture with improved power efficiency. Results : We examined wireless capacity using heterogenous bovine tissue, demonstrating >5 V stimulation threshold with up to 20 mm transmitter-receiver displacement and 20° of misalignment. Feasibility for human use was validated using Finite Element Method (FEM) simulation of the cardiac cycle, guided by pacer phantom-integrated Magnetic Resonance Images (MRI). Conclusion : This system design thus enabled sufficient wireless power transfer in the face of extensive stimulator miniaturization. Significance : Our successful feasibility studies demonstrated the capacity for minimally invasive deployment and low-risk fixation

    A Multi-Dimensional Analysis of a Novel Approach for Wireless Stimulation

    Get PDF
    The elimination of integrated batteries in biomedical implants holds great promise for improving health outcomes in patients with implantable devices. However, despite extensive research in wireless power transfer, achieving efficient power transfer and effective operational range have remained a hindering challenge within anatomical constraints. Objective : We hereby demonstrate an intravascular wireless and batteryless microscale stimulator, designed for (1) low power dissipation via intermittent transmission and (2) reduced fixation mechanical burden via deployment to the anterior cardiac vein (ACV, ∼3.8 mm in diameter). Methods : We introduced a unique coil design circumferentially confined to a 3 mm diameter hollow-cylinder that was driven by a novel transmitter-based control architecture with improved power efficiency. Results : We examined wireless capacity using heterogenous bovine tissue, demonstrating >5 V stimulation threshold with up to 20 mm transmitter-receiver displacement and 20° of misalignment. Feasibility for human use was validated using Finite Element Method (FEM) simulation of the cardiac cycle, guided by pacer phantom-integrated Magnetic Resonance Images (MRI). Conclusion : This system design thus enabled sufficient wireless power transfer in the face of extensive stimulator miniaturization. Significance : Our successful feasibility studies demonstrated the capacity for minimally invasive deployment and low-risk fixation

    Acoustic power distribution techniques for wireless sensor networks

    Get PDF
    Recent advancements in wireless power transfer technologies can solve several residual problems concerning the maintenance of wireless sensor networks. Among these, air-based acoustic systems are still less exploited, with considerable potential for powering sensor nodes. This thesis aims to understand the significant parameters for acoustic power transfer in air, comprehend the losses, and quantify the limitations in terms of distance, alignment, frequency, and power transfer efficiency. This research outlines the basic concepts and equations overlooking sound wave propagation, system losses, and safety regulations to understand the prospects and limitations of acoustic power transfer. First, a theoretical model was established to define the diffraction and attenuation losses in the system. Different off-the-shelf transducers were experimentally investigated, showing that the FUS-40E transducer is most appropriate for this work. Subsequently, different load-matching techniques are analysed to identify the optimum method to deliver power. The analytical results were experimentally validated, and complex impedance matching increased the bandwidth from 1.5 to 4 and the power transfer efficiency from 0.02% to 0.43%. Subsequently, a detailed 3D profiling of the acoustic system in the far-field region was provided, analysing the receiver sensitivity to disturbances in separation distance, receiver orientation and alignment. The measured effects of misalignment between the transducers are provided as a design graph, correlating the output power as a function of separation distance, offset, loading methods and operating frequency. Finally, a two-stage wireless power network is designed, where energy packets are inductively delivered to a cluster of nodes by a recharge vehicle and later acoustically distributed to devices within the cluster. A novel dynamic recharge scheduling algorithm that combines weighted genetic clustering with nearest neighbour search is developed to jointly minimise vehicle travel distance and power transfer losses. The efficacy and performance of the algorithm are evaluated in simulation using experimentally derived traces that presented 90% throughput for large, dense networks.Open Acces

    Comparative analysis of energy transfer mechanisms for neural implants

    Get PDF
    As neural implant technologies advance rapidly, a nuanced understanding of their powering mechanisms becomes indispensable, especially given the long-term biocompatibility risks like oxidative stress and inflammation, which can be aggravated by recurrent surgeries, including battery replacements. This review delves into a comprehensive analysis, starting with biocompatibility considerations for both energy storage units and transfer methods. The review focuses on four main mechanisms for powering neural implants: Electromagnetic, Acoustic, Optical, and Direct Connection to the Body. Among these, Electromagnetic Methods include techniques such as Near-Field Communication (RF). Acoustic methods using high-frequency ultrasound offer advantages in power transmission efficiency and multi-node interrogation capabilities. Optical methods, although still in early development, show promising energy transmission efficiencies using Near-Infrared (NIR) light while avoiding electromagnetic interference. Direct connections, while efficient, pose substantial safety risks, including infection and micromotion disturbances within neural tissue. The review employs key metrics such as specific absorption rate (SAR) and energy transfer efficiency for a nuanced evaluation of these methods. It also discusses recent innovations like the Sectored-Multi Ring Ultrasonic Transducer (S-MRUT), Stentrode, and Neural Dust. Ultimately, this review aims to help researchers, clinicians, and engineers better understand the challenges of and potentially create new solutions for powering neural implants

    Self Capacitance based Wireless Power Transfer for Wearable Electronics: Theory and Implementation

    Get PDF
    Wireless power transfer (WPT

    Theory, Design and Implementation of Energy-Efficient Biotelemetry using Ultrasound Imaging

    Get PDF
    This dissertation investigates the fundamental limits of energy dissipation in establishing a communication link with implantable medical devices using ultrasound imaging-based biotelemetry. Ultrasound imaging technology has undergone a revolution during the last decade due to two primary innovations: advances in ultrasonic transducers that can operate over a broad range of frequencies and progresses in high-speed, high-resolution analog-to-digital converters and signal processors. Existing clinical and FDA approved bench-top ultrasound systems cangenerate real-time high-resolution images at frame rates as high as 10000 frames per second. On the other end of the spectrum, portable and hand-held ultrasound systems can generate high-speed real-time scans, widely used for diagnostic imaging in non-clinical environments. This dissertation’s fundamental hypothesis is to leverage the massive data acquisition and computational bandwidth afforded on these devices to establish energy-efficient bio-telemetry links with multiple in-vivo implanted devices. In the first part of the dissertation, I investigate using a commercial off-the-shelf (COTS) diagnostic ultrasound reader to achieve reliable in-vivo wireless telemetry with millimeter-sized piezoelectric crystal transducers. I propose multi-access biotelemetry methods in which several of these crystals simultaneously transmit the data using conventional modulation and coding schemes. I validated the feasibility of in-vivo operation using two piezoelectric crystals tethered to the tricuspid valve and the skin’s surface in a live ovine model. I demonstrated data rates close to 800 Kbps while consuming microwatts of power even in the presence of respiratory and cardiac motion artifacts. In the second part of the dissertation, I investigate the feasibility of energy harvesting from cardiac valvular perturbations to self-power the wireless implantable device. In this study, I explored using piezoelectric sutures implanted in proximity to the valvular regions compared to the previous studies involving piezoelectric patches or encasings attached to the cardiac or aortic surface to exploit nonlinearity in the valvular dynamics and self-power the implanted device. My study shows that power harvested from different annular planes of the tricuspid valve could range from nano-watts to milli-watts. In the final part of this dissertation, I investigate beamforming in B-scan ultrasound imaging to further reduce the biotelemetry energy-budget. In this context, I will study variance-based informatics in which the signal representation takes a form of signal variance instead of the signal mean for encoding and decoding. Using a modeling study, I show that compared to the mean-based logic representation, the variance-based representation can theoretically achieve a superior performance trade-off (in terms of energy dissipation) when operating at fundamental limits imposed by thermal-noise. I will then discuss how to extend variance-based representation to higher signal dimensions. I show that when applying variance-based encoding/decoding to B-scan biotelemetry, the power-dissipation requirements can be reducedto 100 pW even while interrogating from depths greater than 10 cm in a water medium
    corecore