344 research outputs found
A self-calibration circuit for a neural spike recording channel
This paper presents a self-calibration circuit for a neural spike recording channel. The proposed design tunes the bandwidth of the signal acquisition Band-Pass Filter (BPF), which suffers from process variations corners. It also performs the adjustment of the Programmable Gain Amplifier (PGA) gain to maximize the input voltage range of the analog-to-digital conversion. The circuit, which consists on a frequency-controlled signal generator and a digital processor, operates in foreground, is completely autonomous and integrable in an estimated area of 0.026mm 2 , with a power consumption around 450nW. The calibration procedure takes less than 250ms to select the configuration whose performance is closest to the required one.Ministerio de Ciencia e InnovaciĂłn TEC2009-08447Junta de AndalucĂa TIC-0281
Recommended from our members
Hippocampus-dependent emergence of spatial sequence coding in retrosplenial cortex.
Retrosplenial cortex (RSC) is involved in visuospatial integration and spatial learning, and RSC neurons exhibit discrete, place cell-like sequential activity that resembles the population code of space in hippocampus. To investigate the origins and population dynamics of this activity, we combined longitudinal cellular calcium imaging of dysgranular RSC neurons in mice with excitotoxic hippocampal lesions. We tracked the emergence and stability of RSC spatial activity over consecutive imaging sessions. Overall, spatial activity in RSC was experience-dependent, emerging gradually over time, but, as seen in the hippocampus, the spatial code changed dynamically across days. Bilateral but not unilateral hippocampal lesions impeded the development of spatial activity in RSC. Thus, the emergence of spatial activity in RSC, a major recipient of hippocampal information, depends critically on an intact hippocampus; the indirect connections between the dysgranular RSC and the hippocampus further indicate that hippocampus may exert such influences polysynaptically within neocortex
Transgenic Mice for Intersectional Targeting of Neural Sensors and Effectors with High Specificity and Performance
SummaryAn increasingly powerful approach for studying brain circuits relies on targeting genetically encoded sensors and effectors to specific cell types. However, current approaches for this are still limited in functionality and specificity. Here we utilize several intersectional strategies to generate multiple transgenic mouse lines expressing high levels of novel genetic tools with high specificity. We developed driver and double reporter mouse lines and viral vectors using the Cre/Flp and Cre/Dre double recombinase systems and established a new, retargetable genomic locus, TIGRE, which allowed the generation of a large set of Cre/tTA-dependent reporter lines expressing fluorescent proteins, genetically encoded calcium, voltage, or glutamate indicators, and optogenetic effectors, all at substantially higher levels than before. High functionality was shown in example mouse lines for GCaMP6, YCX2.60, VSFP Butterfly 1.2, and Jaws. These novel transgenic lines greatly expand the ability to monitor and manipulate neuronal activities with increased specificity.Video Abstrac
Automatic identification of gait events using an instrumented sock
Background: textile-based transducers are an emerging technology in which piezo-resistive properties of materials
are used to measure an applied strain. By incorporating these sensors into a sock, this technology offers the
potential to detect critical events during the stance phase of the gait cycle. This could prove useful in several
applications, such as functional electrical stimulation (FES) systems to assist gait.
Methods: we investigated the output of a knitted resistive strain sensor during walking and sought to determine
the degree of similarity between the sensor output and the ankle angle in the sagittal plane. In addition, we
investigated whether it would be possible to predict three key gait events, heel strike, heel lift and toe off, with a
relatively straight-forward algorithm. This worked by predicting gait events to occur at fixed time offsets from
specific peaks in the sensor signal.
Results: our results showed that, for all subjects, the sensor output exhibited the same general characteristics as
the ankle joint angle. However, there were large between-subjects differences in the degree of similarity between
the two curves. Despite this variability, it was possible to accurately predict gait events using a simple algorithm.
This algorithm displayed high levels of trial-to-trial repeatability.
Conclusions: this study demonstrates the potential of using textile-based transducers in future devices that provide active gait assistance
Accelerated hermeticity testing of biocompatible moisture barriers used for the encapsulation of implantable medical devices
Barrier layers for the long-term encapsulation of implantable medical devices play a crucial role in the devicesâ performance and reliability. Typically, to understand the stability and predict the lifetime of barriers (therefore, the implantable devices), the device is subjected to accelerated testing at higher temperatures compared to its service parameters. Nevertheless, at high temperatures, reaction and degradation mechanisms might be different, resulting in false accelerated test results. In this study, the maximum valid temperatures for the accelerated testing of two barrier layers were investigated: atomic layer deposited (ALD) Al2O3 and stacked ALD HfO2/Al2O3/HfO2, hereinafter referred to as ALD-3. The in-house developed standard barrier performance test is based on continuous electrical resistance monitoring and microscopic inspection of Cu patterns covered with the barrier and immersed in phosphate buffered saline (PBS) at temperatures up to 95 °C. The results demonstrate the valid temperature window to perform temperature acceleration tests. In addition, the optimized ALD layer in combination with polyimide (polyimide/ALD-3/polyimide) works as effective barrier at 60 °C for 1215 days, suggesting the potential applicability to the encapsulation of long-term implants
Recommended from our members
Arousal regulates frequency tuning in primary auditory cortex.
Changes in arousal influence cortical sensory representations, but the synaptic mechanisms underlying arousal-dependent modulation of cortical processing are unclear. Here, we use 2-photon Ca2+ imaging in the auditory cortex of awake mice to show that heightened arousal, as indexed by pupil diameter, broadens frequency-tuned activity of layer 2/3 (L2/3) pyramidal cells. Sensory representations are less sparse, and the tuning of nearby cells more similar when arousal increases. Despite the reduction in selectivity, frequency discrimination by cell ensembles improves due to a decrease in shared trial-to-trial variability. In vivo whole-cell recordings reveal that mechanisms contributing to the effects of arousal on sensory representations include state-dependent modulation of membrane potential dynamics, spontaneous firing, and tone-evoked synaptic potentials. Surprisingly, changes in short-latency tone-evoked excitatory input cannot explain the effects of arousal on the broadness of frequency-tuned output. However, we show that arousal strongly modulates a slow tone-evoked suppression of recurrent excitation underlying lateral inhibition [H. K. Kato, S. K. Asinof, J. S. Isaacson, Neuron, 95, 412-423, (2017)]. This arousal-dependent "network suppression" gates the duration of tone-evoked responses and regulates the broadness of frequency tuning. Thus, arousal can shape tuning via modulation of indirect changes in recurrent network activity
Active C4 electrodes for local field potential recording applications
Extracellular neural recording, with multi-electrode arrays (MEAs), is a powerful method used to study neural function at the network level. However, in a high density array, it can be costly and time consuming to integrate the active circuit with the expensive electrodes. In this paper, we present a 4 mm Ă 4 mm neural recording integrated circuit (IC) chip, utilizing IBM C4 bumps as recording electrodes, which enable a seamless active chip and electrode integration. The IC chip was designed and fabricated in a 0.13 ÎŒm BiCMOS process for both in vitro and in vivo applications. It has an input-referred noise of 4.6 ÎŒV rms for the bandwidth of 10 Hz to 10 kHz and a power dissipation of 11.25 mW at 2.5 V, or 43.9 ÎŒW per input channel. This prototype is scalable for implementing larger number and higher density electrode arrays. To validate the functionality of the chip, electrical testing results and acute in vivo recordings from a rat barrel cortex are presented.R01 NS072385 - NINDS NIH HHS; 1R01 NS072385 - NINDS NIH HH
Ultra-long-term reliable encapsulation using an atomic layer deposited Hfo2/Al2o3/Hfo2 triple-interlayer for biomedical implants
Long-term packaging of miniaturized, flexible implantable medical devices is essential for the next generation of medical devices. Polymer materials that are biocompatible and flexible have attracted extensive interest for the packaging of implantable medical devices, however realizing these devices with long-term hermeticity up to several years remains a great challenge. Here, polyimide (PI) based hermetic encapsulation was greatly improved by atomic layer deposition (ALD) of a nanoscale-thin, biocompatible sandwich stack of HfO2/Al2O3/HfO2 (ALD-3) between two polyimide layers. A thin copper film covered with a PI/ALD-3/PI barrier maintained excellent electrochemical performance over 1028 days (2.8 years) during acceleration tests at 60 °C in phosphate buffered saline solution (PBS). This stability is equivalent to approximately 14 years at 37 °C. The coatings were monitored in situ through electrochemical impedance spectroscopy (EIS), were inspected by microscope, and were further analyzed using equivalent circuit modeling. The failure mode of ALD Al2O3, ALD-3, and PI soaking in PBS is discussed. Encapsulation using ultrathin ALD-3 combined with PI for the packaging of implantable medical devices is robust at the acceleration temperature condition for more than 2.8 years, showing that it has great potential as reliable packaging for long-term implantable devices
- âŠ