    Multi-drug infusion control using model reference adaptive algorithm

    Get PDF
    Control of physiological states such as mean arterial pressure (MAP) has been successfully achieved using single drug by different control algorithms. Multi-drug delivery demonstrates a significantly challenging task as compared to control with a single-drug. Also the patient’s sensitivity to the drugs varies from patient to patient. Therefore, the implementation of adaptive controller is very essential to improve the patient care in order to reduce the workload of healthcare staff and costs. This paper presents the design and implementation of the model reference adaptive controller (MRAC) to regulate mean arterial pressure and cardiac output by administering vasoactive and inotropic drugs that are sodium nitroprusside (SNP) and dopamine (DPM) respectively. The proposed adaptive control model has been implemented, tested and verified to demonstrate its merits and capabilities as compared to the existing research work

    A no-nonsense control engineering approach to anaesthesia control during induction phase

    Get PDF

    Depth of anesthesia control using internal model control techniques

    Get PDF
    The major difficulty in the design of closed-loop control during anaesthesia is the inherent patient variability due to differences in demographic and drug tolerance. These discrepancies are translated into the pharmacokinetics (PK), and pharmacodynamics (PD). These uncertainties may affect the stability of the closed loop control system. This paper aims at developing predictive controllers using Internal Model Control technique. This study develops patient dose-response models and to provide an adequate drug administration regimen for the anaesthesia to avoid under or over dosing of the patients. The controllers are designed to compensate for patients inherent drug response variability, to achieve the best output disturbance rejection, and to maintain optimal set point response. The results are evaluated compared with traditional PID controller and the performance is confirmed in our simulation

    Optimal Regulation of Blood Glucose Level in Type I Diabetes using Insulin and Glucagon

    Full text link
    The Glucose-Insulin-Glucagon nonlinear model [1-4] accurately describes how the body responds to exogenously supplied insulin and glucagon in patients affected by Type I diabetes. Based on this model, we design infusion rates of either insulin (monotherapy) or insulin and glucagon (dual therapy) that can optimally maintain the blood glucose level within desired limits after consumption of a meal and prevent the onset of both hypoglycemia and hyperglycemia. This problem is formulated as a nonlinear optimal control problem, which we solve using the numerical optimal control package PSOPT. Interestingly, in the case of monotherapy, we find the optimal solution is close to the standard method of insulin based glucose regulation, which is to assume a variable amount of insulin half an hour before each meal. We also find that the optimal dual therapy (that uses both insulin and glucagon) is better able to regulate glucose as compared to using insulin alone. We also propose an ad-hoc rule for both the dosage and the time of delivery of insulin and glucagon.Comment: Accepted for publication in PLOS ON

    Closed-Loop Control of Anaesthetic Effect

    Get PDF
    Archivo disponible en la web de la revista, Open Access, en la siguiente URL: https://www.intechopen.com/books/pharmacology/closed-loop-control-of-anesthetic-effect Se puede referenciar de la siguiente manera: Santiago Torres, Juan A. Méndez, Héctor Reboso, José A. Reboso and Ana León (2012). Closed-Loop Control of Anaesthetic Effect, Pharmacology, Dr. Luca Gallelli (Ed.), InTech, DOI: 10.5772/37609. Available from: https://www.intechopen.com/books/pharmacology/closed-loop-control-of-anesthet

    Mathematical model of brain tumour with glia-neuron interactions and chemotherapy treatment

    Get PDF
    Acknowledgements This study was possible by partial financial support from the following Brazilian government agencies: Fundação Araucåria, EPSRC-EP/I032606/1 and CNPq, CAPES and Science Without Borders Program Process nos. 17656125, 99999.010583/2013-00 and 245377/2012-3.Peer reviewedPreprin

    Multi-model adaptive predictive control system for automated regulation of mean blood pressure

    Get PDF
    After cardiac surgery operation, severe complications may occur in patients due to hypertension. To decrease the chances of complication it is necessary to reduce elevated mean arterial pressure (MAP) as soon as possible. Continuous infusion of vasodilator drugs, such as sodium nitroprusside (Nipride), it is used to reduce MAP quickly in most patients. For maintaining the desired blood pressure, a constant monitoring of arterial blood pressure is required and a frequently adjust on drug infusion rate. The manual control of arterial blood pressure by clinical professionals it is very demanding and time consuming, usually leading to a poor control quality of the hypertension. The objective of the study is to develop an automated control procedure of mean arterial pressure (MAP), during acute hypotension, for any patient, without changing the controller. So, a multi-model adaptive predictive methodology was developed and, for each model, a Predictive Controller can be a priori designed (MMSPGPC). In this paper, a sensitivity analysis was performed and the simulation results showed the importance of weighting factor (phi), which controls the initial drug infusion rate, to prevent hypotension and thus preserve patient's health. Simulation results, for 51 different patients, showed that the MMSPGPC provides a fast control with mean settling time of 04:46 min, undershoots less than 10 mmHg and steady-state error less than +/- 5 % from the MAP setpoint.The authors of this article would like to thank Federal Institute of Rio Grande do Norte for support and University of Minho for structure, which to made possible the development of the research

    Comparison of the qCON and qNOX indices for the assessment of unconsciousness level and noxious stimulation response during surgery

    Get PDF
    The objective of this work is to compare the performances of two electroencephalogram based indices for detecting loss of consciousness and loss of response to nociceptive stimulation. Specifically, their behaviour after drug induction and during recovery of consciousness was pointed out. Data was recorded from 140 patients scheduled for general anaesthesia with a combination of propofol and remifentanil. The qCON 2000 monitor (Quantium Medical, Barcelona, Spain) was used to calculate the qCON and qNOX. Loss of response to verbal command and loss of eye-lash reflex were assessed during the transition from awake to anesthetized, defining the state of loss of consciousness. Movement as a response to laryngeal mask (LMA) insertion was interpreted as the response to the nociceptive stimuli. The patients were classified as movers or non-movers. The values of qCON and qNOX were statistically compared. Their fall times and rise times defined at the start and at the end of the surgery were calculated and compared. The results showed that the qCON was able to predict loss of consciousness such as loss of verbal command and eyelash reflex better than qNOX, while the qNOX has a better predictive value for response to noxious stimulation such as LMA insertion. From the analysis of the fall and rise times, it was found that the qNOX fall time (median: 217 s) was significantly longer (p value <0.05) than the qCON fall time (median: 150 s). At the end of the surgery, the qNOX started to increase in median at 45 s before the first annotation related to response to stimuli or recovery of consciousness, while the qCON at 88 s after the first annotation related to response to stimuli or recovery of consciousness (p value <0.05). The indices qCON and qNOX showed different performances in the detection of loss of consciousness and loss of response to stimuli during induction and recovery of consciousness. Furthermore, the qCON showed faster decrease during induction. This behaviour is associated with the hypothesis that the loss of response to stimuli (analgesic effect) might be reached after the loss of consciousness (hypnotic effect). On the contrary, the qNOX showed a faster increase at the end of the surgery, associated with the hypothesis that a higher probability of response to stimuli might be reached before the recovery of consciousness.Postprint (author's final draft
    • 