1,825 research outputs found

    A Comparative Study Between a Micromechanical Cantilever Resonator and MEMS-based Passives for Band-pass Filtering Application

    Full text link
    Over the past few years, significant growth has been observed in using MEMS based passive components in the RF microelectronics domain, especially in transceiver components. This is due to some excellent properties of the MEMS devices like low loss, excellent isolation etc. in the microwave frequency domain where the on-chip passives normally tend to become leakier and degrades the transceiver performance. This paper presents a comparative analysis between MEMS-resonator based and MEMS-passives based band-pass filter configurations for RF applications, along with their design, simulation, fabrication and characterization. The filters were designed to have a center frequency of 455 kHz, meant for use as the intermediate frequency (IF) filter in superheterodyne receivers. The filter structures have been fabricated in PolyMUMPs process, a three-polysilicon layer surface micromachining process.Comment: 6 pages, 15 figure

    A Review of Smart Materials in Tactile Actuators for Information Delivery

    Full text link
    As the largest organ in the human body, the skin provides the important sensory channel for humans to receive external stimulations based on touch. By the information perceived through touch, people can feel and guess the properties of objects, like weight, temperature, textures, and motion, etc. In fact, those properties are nerve stimuli to our brain received by different kinds of receptors in the skin. Mechanical, electrical, and thermal stimuli can stimulate these receptors and cause different information to be conveyed through the nerves. Technologies for actuators to provide mechanical, electrical or thermal stimuli have been developed. These include static or vibrational actuation, electrostatic stimulation, focused ultrasound, and more. Smart materials, such as piezoelectric materials, carbon nanotubes, and shape memory alloys, play important roles in providing actuation for tactile sensation. This paper aims to review the background biological knowledge of human tactile sensing, to give an understanding of how we sense and interact with the world through the sense of touch, as well as the conventional and state-of-the-art technologies of tactile actuators for tactile feedback delivery

    Particle Sensor Using Solidly Mounted Resonators

    Get PDF
    This paper describes the development of a novel particle sensing system employing zinc oxide based solidly mounted resonator (SMR) devices for the detection of airborne fine particles (i.e., PM2.5 and PM10). The system operates in a dual configuration in which two SMR devices are driven by Colpitts-type oscillators in a differential mode. Particles are detected by the frequency shift caused by the mass of particles present on one resonator with while the other acts as a reference channel. Experimental validation of the system was performed inside an environmental chamber using a dust generator with the particles of known size and concentration. A sensor sensitivity of 4.6 Hz per Ī¼g/m3 was demonstrated for the SMRs resonating at a frequency of 970 MHz. Our results demonstrate that the SMR-based system has the potential to be implemented in CMOS technology as a low-cost, miniature smart particle detector for the real-time monitoring of airborne particles

    Acoustic Wave Based MEMS Devices, Development and Applications

    Get PDF
    Acoustic waves based MEMS devices offer a promising technology platform for a wide range of applications due to their high sensitivity and the capability to operate wirelessly. These devices utilize acoustic waves propagating through or on the surface of a piezoelectric material. An acoustic wave device typically consists of two layers, metal transducers on top of piezoelectric substrate or thin films. The piezoelectric material has inherent capabilities of generating acoustic waves related to the input electrical sinusoidal signals placed on the transducers. Using this characteristic, different transducer designs can be placed on top of the piezoelectric material to create acoustic wave based filters, resonators or sensors. Historically, acoustic wave devices have been and are still widely used in telecommunications industry, primarily in mobile cell phones and base stations. Surface Acoustic Wave (SAW) devices are capable of performing powerful signal processing and have been successfully functioning as filters, resonators and duplexers for the past 60 years. Although SAW devices are technological mature and have served the telecommunication industry for several decades, these devices are typically fabricated on piezoelectric substrates and are packaged as discrete components. Considering the wide flexibility and capabilities of the SAW device to form filters, resonators there has been motivation to integrate such devices on silicon substrates as demonstrated in (Nordin et al., 2007; M. J. Vellekoop et al., 1987; Visser et al., 1989). One such example is illustrated in (Nordin et al., 2007) where a CMOS SAW resonator was fabricated using 0.6 m AMIs CMOS technology process with additional MEMS post-processing. The traditional SAW structure of having the piezoelectric at the bottom was inverted. Instead, the IDTs were cleverly manufactured using standard complementary-metal-oxide-semiconductor (CMOS) process and the piezoelectric layer was placed on the top. Active circuitry can be placed adjacent to the CMOS resonator and can be connected using the integrated metal layers. A SAW device can also be designed to have a long propagation path between the input and output transducer. The propagating acoustic waves will then be very sensitive to ambient changes, allowing the device to act as a sensor. Any variations to the characteristics of the propagation path affect the velocity or amplitude of the wave. Important application for acoustic wave devices as sensors include torque and tire pressure sensors (Cullen et al., 1980; Cullen et al., 1975; Pohl et al., 1997), gas sensors (Levit et al., 2002; Nakamoto et al., 1996; Staples, 1999; Wohltjen et al., 1979), biosensors for medical applications (Andle et al., 1995; Ballantine et al., 1996; Cavic et al., 1999; Janshoff et al., 2000), and industrial and commercial applications (vapor, humidity, temperature, and mass sensors) (Bowers et al., 1991; Cheeke et al., 1996; Smith, 2001; N. J. Vellekoop et al., 1999; Vetelino et al., 1996; Weld et al., 1999). In recent years, the interest in the development of highly sensitive acoustic wave devices as biosensor platforms has grown. For biological applications the acoustic wave device is integrated in a microfluidic system and the sensing area is coated with a biospecific layer. When a bioanalyte interacts with this sensing layer, physical, chemical, and/or biochemical changes are produced. Typically, mass and viscosity changes of the biospecific layer can be detected by analyzing changes in the acoustic wave properties such as velocity, attenuation and resonant frequency of the sensor. An important advantage of the acoustic wave biosensors is simple electronic readout that characterizes these sensors. The measurement of the resonant frequency or time delay can be performed with high degree of precision using conventional electronics. This chapter is focused on two important applications of the acoustic-wave based MEMS devices; (1) biosensors and (2) telecommunications. For biological applications these devices are integrated in a microfluidic system and the sensing area is coated with a biospecific layer. When a bioanalyte interacts with this sensing layer, physical, chemical, and/or biochemical changes are produced. Typically, mass and viscosity changes of the biospecific layer can be detected by analyzing changes in the acoustic wave properties such as velocity, attenuation and resonant frequency of the sensor. An important advantage of the acoustic wave biosensors is simple electronic readout that characterizes these sensors. The measurement of the resonant frequency and time delay can be performed with high degree of precision using conventional electronics. Only few types of acoustic wave devices could be integrated in microfluidic systems without significant degradation of the quality factor. The acoustic wave based MEMS devices reported in the literature as biosensors are film bulk acoustic wave resonators (FBAR) and surface acoustic waves (SAW) resonators and SAW delay lines. Different approaches to the realization of FBARs and SAW resonators and SAW delay lines used for various biochemical applications are presented. Next, acoustic wave MEMS devices used in telecommunications applications are presented. Telecommunication devices have different requirements compared to sensors, where acoustic wave devices operating as a filter or resonator are expected to operate at high frequencies (GHz), have high quality factors and low insertion losses. Traditionally, SAW devices have been widely used in the telecommunications industry, however with advancement in lithographic techniques, FBARs are rapidly gaining popularity. FBARs have the advantage of meeting the stringent requirement of telecommunication industry of having Qs in the 10,000 range and silicon compatibility

    Design and modelling of solidly mounted resonators for low-cost particle sensing

    Get PDF
    This work presents the design and fabrication of Solidly Mounted Resonator (SMR) devices for the detection of particulate matter (PM2.5 and PM10) in order to develop a smart low-cost particle sensor for air quality. These devices were designed to operate at a resonant frequency of either 870 MHz or 1.5 GHz, employing zinc oxide as the piezoelectric layer and an acoustic mirror made from molybdenum and silicon dioxide layers. Finite element analysis of the acoustic resonators was performed using COMSOL Multiphysics software in order to evaluate the frequency response of the devices and the performance of the acoustic mirror. The zinc oxide based acoustic resonators were fabricated on a silicon substrate using a five mask process. The mass sensitivity of the acoustic resonators was estimated using a 3-D finite element model and preliminary testing has been performed. The theoretical and observed mass sensitivity were similar at ca. 145 kHz/ng for the 870 MHz resonator when detecting PM2.5 suggesting that SMR devices have potential to be used as part of a miniature smart sensor system for airborne particle detection.This work was funded under the European Commission 7th Framework Programme, Project No. 611887, ā€œMulti-Sensor-Platform for Smart Building Management: MSPā€. F.H.Villa-Lopez thanks the financial support from the National Mexican Council of Science and Technology (CONACYT). G. Rughoobur wishes to acknowledge financial support from the Cambridge Trusts.This is the author accepted manuscript. The final version is available from IOP via http://dx.doi.org/10.1088/0957-0233/27/2/02510

    Ultrafine Aerosol Particle Sizer Based on Piezoresistive Microcantilever Resonators with Integrated Air-Flow Channel

    Get PDF
    To monitor airborne nano-sized particles (NPs), a single-chip differential mobility particle sizer (DMPS) based on resonant micro cantilevers in defined micro-fluidic channels (ĀµFCs) is introduced. A size bin of the positive-charged fraction of particles herein is separated from the air stream by aligning their trajectories onto the cantilever under the action of a perpendicular electrostatic field of variable strength. We use previously described ĀµFCs and piezoresistive micro cantilevers (PMCs) of 16 ng mass fabricated using micro electro mechanical system (MEMS) technology, which offer a limit of detection of captured particle mass of 0.26 pg and a minimum detectable particulate mass concentration in air of 0.75 Āµg/m3. Mobility sizing in 4 bins of a nebulized carbon aerosol NPs is demonstrated based on finite element modelling (FEM) combined with a-priori knowledge of particle charge state. Good agreement of better than 14% of mass concentration is observed in a chamber test for the novel MEMS-DMPS vs. a simultaneously operated standard fast mobility particle sizer (FMPS) as reference instrument. Refreshing of polluted cantilevers is feasible without de-mounting the sensor chip from its package by multiply purging them alternately in acetone steam and clean air
    • ā€¦
    corecore