417 research outputs found
Weakly-supervised localization of diabetic retinopathy lesions in retinal fundus images
Convolutional neural networks (CNNs) show impressive performance for image
classification and detection, extending heavily to the medical image domain.
Nevertheless, medical experts are sceptical in these predictions as the
nonlinear multilayer structure resulting in a classification outcome is not
directly graspable. Recently, approaches have been shown which help the user to
understand the discriminative regions within an image which are decisive for
the CNN to conclude to a certain class. Although these approaches could help to
build trust in the CNNs predictions, they are only slightly shown to work with
medical image data which often poses a challenge as the decision for a class
relies on different lesion areas scattered around the entire image. Using the
DiaretDB1 dataset, we show that on retina images different lesion areas
fundamental for diabetic retinopathy are detected on an image level with high
accuracy, comparable or exceeding supervised methods. On lesion level, we
achieve few false positives with high sensitivity, though, the network is
solely trained on image-level labels which do not include information about
existing lesions. Classifying between diseased and healthy images, we achieve
an AUC of 0.954 on the DiaretDB1.Comment: Accepted in Proc. IEEE International Conference on Image Processing
(ICIP), 201
Binary operation based hard exudate detection and fuzzy based classification in diabetic retinal fundus images for real time diagnosis applications
Diabetic retinopathy (DR) is one of the most considerable reasons for visual impairment. The main objective of this paper is to automatically detect and recognize DR lesions like hard exudates, as it helps in diagnosing and screening of the disease. Here, binary operation based image processing for detecting lesions and fuzzy logic based extraction of hard exudates on diabetic retinal images are discused. In the initial stage, the binary operations are used to identify the exudates. Similarly, the RGB channel space of the DR image is used to create fuzzy sets and membership functions for extracting the exudates. The membership directives obtained from the fuzzy rule set are used to detect the grade of exudates. In order to evaluate the proposed approach, experiment tests are carriedout on various set of images and the results are verified. From the experiment results, the sensitivity obtained is 98.10%, specificity is 96.96% and accuracy is 98.2%. These results suggest that the proposed method could be a diagnostic aid for ophthalmologists in the screening for DR
Refining Coarse Manual Segmentations with Stable Probability Regions
Most feature-based lesion detection and computer-aided diagnosis methods for medical images require representative data of each region of interest (ROI) for parameter selection. Furthermore, the spatial accuracy of the segmentation of the ROIs from the background can significantly affect certain image features extracted from the ROIs. How- ever, requiring spatially accurate manual segmentations of the ROIs to be used as the ground truth is infeasible for large image sets due to the amount of manual work involved. To relax the requirement of spatial accuracy and to enable spatial refinement of coarse manual segmentations to have more representative feature data, a method based on color information and maximally stable extremal regions of lesion likelihoods is presented. The proposed method is quantitatively compared to several segmentation approaches by using a challenging set of retinal images with spatially accurate ground truth of exudates. The experiments show that the proposed method produces good results measured as Dice coefficients between the refined segmentation and ground truth
Improving the economic value of photographic screening for optical coherence tomography-detectable macular oedema : a prospective, multicentre, UK study
Peer reviewedPublisher PD
DETECTION AND SEGMENTATION OF OPTIC DISC IN FUNDUS IMAGES
Objective: Image processing technique is utilized in the medical field widely nowadays. Hence, therefore, this technique is used to extract the different features like blood vessels, optic disk, macula, fovea etc. automatically of the retinal image of eye.Methods: This paper presents a simple and fast algorithm using Mathematical Morphology to find the fovea of fundus retinal image. The image for analysis is obtained from the DRIVE database. Also, this paper is enhanced to detect the Diabetic Retinopathy disease occurring in the eye.Results: Detection of optic disc boundary becomes important for the diagnosis of glaucoma. The iterative curve evolution was stopped at the image boundaries where the energy was minimum.Conclusion: The changes in the shape and size of the optic disc can be used to detect glaucoma and also cup ratio can be used as a measure of glaucoma
Computational Analysis of Fundus Images: Rule-Based and Scale-Space Models
Fundus images are one of the most important imaging examinations in modern ophthalmology
because they are simple, inexpensive and, above all, noninvasive.
Nowadays, the acquisition and
storage of highresolution
fundus images is relatively easy and fast. Therefore, fundus imaging
has become a fundamental investigation in retinal lesion detection, ocular health monitoring and
screening programmes. Given the large volume and clinical complexity associated with these images,
their analysis and interpretation by trained clinicians becomes a timeconsuming
task and is
prone to human error. Therefore, there is a growing interest in developing automated approaches
that are affordable and have high sensitivity and specificity. These automated approaches need to
be robust if they are to be used in the general population to diagnose and track retinal diseases. To
be effective, the automated systems must be able to recognize normal structures and distinguish
them from pathological clinical manifestations.
The main objective of the research leading to this thesis was to develop automated systems capable
of recognizing and segmenting retinal anatomical structures and retinal pathological clinical
manifestations associated with the most common retinal diseases. In particular, these automated
algorithms were developed on the premise of robustness and efficiency to deal with the difficulties
and complexity inherent in these images. Four objectives were considered in the analysis of
fundus images. Segmentation of exudates, localization of the optic disc, detection of the midline
of blood vessels, segmentation of the vascular network and detection of microaneurysms.
In addition, we also evaluated the detection of diabetic retinopathy on fundus images using the
microaneurysm detection method. An overview of the state of the art is presented to compare the
performance of the developed approaches with the main methods described in the literature for
each of the previously described objectives. To facilitate the comparison of methods, the state of
the art has been divided into rulebased
methods and machine learningbased
methods.
In the research reported in this paper, rulebased
methods based on image processing methods
were preferred over machine learningbased
methods. In particular, scalespace
methods proved
to be effective in achieving the set goals.
Two different approaches to exudate segmentation were developed. The first approach is based on
scalespace
curvature in combination with the local maximum of a scalespace
blob detector and
dynamic thresholds. The second approach is based on the analysis of the distribution function of
the maximum values of the noise map in combination with morphological operators and adaptive
thresholds. Both approaches perform a correct segmentation of the exudates and cope well with
the uneven illumination and contrast variations in the fundus images.
Optic disc localization was achieved using a new technique called cumulative sum fields, which was
combined with a vascular enhancement method. The algorithm proved to be reliable and efficient,
especially for pathological images. The robustness of the method was tested on 8 datasets.
The detection of the midline of the blood vessels was achieved using a modified corner detector
in combination with binary philtres and dynamic thresholding. Segmentation of the vascular network
was achieved using a new scalespace
blood vessels enhancement method. The developed
methods have proven effective in detecting the midline of blood vessels and segmenting vascular
networks.
The microaneurysm detection method relies on a scalespace
microaneurysm detection and labelling
system. A new approach based on the neighbourhood of the microaneurysms was used
for labelling. Microaneurysm detection enabled the assessment of diabetic retinopathy detection.
The microaneurysm detection method proved to be competitive with other methods, especially with highresolution
images. Diabetic retinopathy detection with the developed microaneurysm
detection method showed similar performance to other methods and human experts.
The results of this work show that it is possible to develop reliable and robust scalespace
methods
that can detect various anatomical structures and pathological features of the retina. Furthermore,
the results obtained in this work show that although recent research has focused on machine learning
methods, scalespace
methods can achieve very competitive results and typically have greater
independence from image acquisition. The methods developed in this work may also be relevant
for the future definition of new descriptors and features that can significantly improve the results
of automated methods.As imagens do fundo do olho são hoje um dos principais exames imagiológicos da oftalmologia
moderna, pela sua simplicidade, baixo custo e acima de tudo pelo seu carácter nãoinvasivo.
A
aquisição e armazenamento de imagens do fundo do olho com alta resolução é também relativamente
simples e rápida. Desta forma, as imagens do fundo do olho são um exame fundamental
na identificação de alterações retinianas, monitorização da saúde ocular, e em programas de rastreio.
Considerando o elevado volume e complexidade clínica associada a estas imagens, a análise
e interpretação das mesmas por clínicos treinados tornase
uma tarefa morosa e propensa a erros
humanos. Assim, há um interesse crescente no desenvolvimento de abordagens automatizadas,
acessíveis em custo, e com uma alta sensibilidade e especificidade. Estas devem ser robustas para
serem aplicadas à população em geral no diagnóstico e seguimento de doenças retinianas. Para
serem eficazes, os sistemas de análise têm que conseguir detetar e distinguir estruturas normais
de sinais patológicos.
O objetivo principal da investigação que levou a esta tese de doutoramento é o desenvolvimento
de sistemas automáticos capazes de detetar e segmentar as estruturas anatómicas da retina, e os
sinais patológicos retinianos associados às doenças retinianas mais comuns. Em particular, estes
algoritmos automatizados foram desenvolvidos segundo as premissas de robustez e eficácia para
lidar com as dificuldades e complexidades inerentes a estas imagens.
Foram considerados quatro objetivos de análise de imagens do fundo do olho. São estes, a segmentação
de exsudados, a localização do disco ótico, a deteção da linha central venosa dos vasos
sanguíneos e segmentação da rede vascular, e a deteção de microaneurismas. De acrescentar que
usando o método de deteção de microaneurismas, avaliouse
também a capacidade de deteção da
retinopatia diabética em imagens do fundo do olho.
Para comparar o desempenho das metodologias desenvolvidas neste trabalho, foi realizado um
levantamento do estado da arte, onde foram considerados os métodos mais relevantes descritos na
literatura para cada um dos objetivos descritos anteriormente. Para facilitar a comparação entre
métodos, o estado da arte foi dividido em metodologias de processamento de imagem e baseadas
em aprendizagem máquina.
Optouse
no trabalho de investigação desenvolvido pela utilização de metodologias de análise espacial
de imagem em detrimento de metodologias baseadas em aprendizagem máquina. Em particular,
as metodologias baseadas no espaço de escalas mostraram ser efetivas na obtenção dos
objetivos estabelecidos.
Para a segmentação de exsudados foram usadas duas abordagens distintas. A primeira abordagem
baseiase
na curvatura em espaço de escalas em conjunto com a resposta máxima local de um detetor
de manchas em espaço de escalas e limiares dinâmicos. A segunda abordagem baseiase
na
análise do mapa de distribuição de ruído em conjunto com operadores morfológicos e limiares
adaptativos. Ambas as abordagens fazem uma segmentação dos exsudados de elevada precisão,
além de lidarem eficazmente com a iluminação nãouniforme
e a variação de contraste presente
nas imagens do fundo do olho. A localização do disco ótico foi conseguida com uma nova técnica
designada por campos de soma acumulativos, combinada com métodos de melhoramento da rede
vascular. O algoritmo revela ser fiável e eficiente, particularmente em imagens patológicas. A robustez
do método foi verificada pela sua avaliação em oito bases de dados. A deteção da linha central
dos vasos sanguíneos foi obtida através de um detetor de cantos modificado em conjunto com
filtros binários e limiares dinâmicos. A segmentação da rede vascular foi conseguida com um novo
método de melhoramento de vasos sanguíneos em espaço de escalas. Os métodos desenvolvidos mostraram ser eficazes na deteção da linha central dos vasos sanguíneos e na segmentação da rede
vascular. Finalmente, o método para a deteção de microaneurismas assenta num formalismo de
espaço de escalas na deteção e na rotulagem dos microaneurismas. Para a rotulagem foi utilizada
uma nova abordagem da vizinhança dos candidatos a microaneurismas. A deteção de microaneurismas
permitiu avaliar também a deteção da retinopatia diabética. O método para a deteção
de microaneurismas mostrou ser competitivo quando comparado com outros métodos, em particular
em imagens de alta resolução. A deteção da retinopatia diabética exibiu um desempenho
semelhante a outros métodos e a especialistas humanos.
Os trabalhos descritos nesta tese mostram ser possível desenvolver uma abordagem fiável e robusta
em espaço de escalas capaz de detetar diferentes estruturas anatómicas e sinais patológicos
da retina.
Além disso, os resultados obtidos mostram que apesar de a pesquisa mais recente concentrarse
em metodologias de aprendizagem máquina, as metodologias de análise espacial apresentam
resultados muito competitivos e tipicamente independentes do equipamento de aquisição das imagens.
As metodologias desenvolvidas nesta tese podem ser importantes na definição de novos
descritores e características, que podem melhorar significativamente o resultado de métodos automatizados
Automatic Segmentation of Optic Disc in Eye Fundus Images: A Survey
Optic disc detection and segmentation is one of the key elements for automatic retinal disease screening systems. The aim of this survey paper is to review, categorize and compare the optic disc detection algorithms and methodologies, giving a description of each of them, highlighting their key points and performance measures. Accordingly, this survey firstly overviews the anatomy of the eye fundus showing its main structural components along with their properties and functions. Consequently, the survey reviews the image enhancement techniques and also categorizes the image segmentation methodologies for the optic disc which include property-based methods, methods based on convergence of blood vessels, and model-based methods. The performance of segmentation algorithms is evaluated using a number of publicly available databases of retinal images via evaluation metrics which include accuracy and true positive rate (i.e. sensitivity). The survey, at the end, describes the different abnormalities occurring within the optic disc region
Automated Detection of Retinal Hemorrhage based on Supervised Classifiers
Supervised machine learning algorithm based retinal hemorrhage detection and classification is presented. For developing an automated diabetic retinopathy screening system, efficient detection of retinal hemorrhage is important. Splat, which is a high level entity in image segmentation is used to mark out hemorrhage in the pre-processed fundus image. Here, color images of retina are portioned into different segments (splats) covereing the whole image. With the help of splat level and GLCM features extracted from the splats, three classifiers are trained and tested using the relevant features. The ground-truth is established with the help of a retinal expert and using dataset and clinical images the validation was done. The output obtained using the three classifiers had more than 96 % sensitivity and accuracy
- …