926 research outputs found

    The NASA SBIR product catalog

    Get PDF
    The purpose of this catalog is to assist small business firms in making the community aware of products emerging from their efforts in the Small Business Innovation Research (SBIR) program. It contains descriptions of some products that have advanced into Phase 3 and others that are identified as prospective products. Both lists of products in this catalog are based on information supplied by NASA SBIR contractors in responding to an invitation to be represented in this document. Generally, all products suggested by the small firms were included in order to meet the goals of information exchange for SBIR results. Of the 444 SBIR contractors NASA queried, 137 provided information on 219 products. The catalog presents the product information in the technology areas listed in the table of contents. Within each area, the products are listed in alphabetical order by product name and are given identifying numbers. Also included is an alphabetical listing of the companies that have products described. This listing cross-references the product list and provides information on the business activity of each firm. In addition, there are three indexes: one a list of firms by states, one that lists the products according to NASA Centers that managed the SBIR projects, and one that lists the products by the relevant Technical Topics utilized in NASA's annual program solicitation under which each SBIR project was selected

    Development and Performance Evaluation of High Resolution TOF-PET Detectors Suitable for Novel PET Scanners

    Full text link
    Tesis por compendio[ES] La Tomografía por Emisión de Positrones (PET) es una de las técnicas más importantes en la medicina de diagnóstico actual y la más representativa en el campo de la Imagen Molecular. Esta modalidad de imagen es capaz de producir información funcional única, que permite la visualización en detalle, cuantificación y conocimiento de una variedad de enfermedades y patologías. Áreas como la oncología, neurología o la cardiología, entre otras, se han beneficiado en gran medida de esta técnica. A pesar de que un elevado número de avances han ocurrido durante el desarrollo del PET, existen otros que son de gran interés para futuras investigaciones. Uno de los principales pilares actualmente en PET, tanto en investigación como en desarrollo, es la obtención de la información del tiempo de vuelo (TOF) de los rayos gamma detectados. Cuando esto ocurre, aumenta la sensibilidad efectiva del PET, mejorando la calidad señal-ruido de las imágenes. Sin embargo, la obtención precisa de la marca temporal de los rayos gamma es un reto que requiere, además de técnicas y métodos específicos, compromisos entre coste y rendimiento. Una de las características que siempre se ve afectada es la resolución espacial. Como discutiremos, la resolución espacial está directamente relacionada con el tipo de centellador y, por lo tanto, con el coste del sistema y su complejidad. En esta tesis, motivada por los conocidos beneficios en imagen clínica de una medida precisa del tiempo y de la posición de los rayos gamma, proponemos configuraciones de detectores TOF- PET novedosos capaces de proveer de ambas características. Sugerimos el uso de lo que se conoce como métodos de "light-sharing", tanto basado en cristales monolíticos como pixelados de tamaño diferente al del fotosensor. Estas propuestas hacen que la resolución espacial sea muy alta. Sin embargo, sus capacidades temporales han sido muy poco abordadas hasta ahora. En esta tesis, a través de varios artículos revisados, pretendemos mostrar los retos encontrados en esta dirección, proponer determinadas configuraciones y, además, indagar en los límites temporales de éstas. Hemos puesto un gran énfasis en estudiar y analizar las distribuciones de la luz centellante, así como su impacto en la determinación temporal. Hasta nuestro conocimiento, este es el primer trabajo en el que se estudia la relación de la determinación temporal y la distribución de luz de centelleo, en particular usando SiPM analógicos y ASICs. Esperamos que esta tesis motive y permita otros muchos trabajos orientados en nuevos diseños, útiles para instrumentación PET, así como referencia para otros trabajos. Esta tesis esta organizada como se describe a continuación. Hay una introducción compuesta por tres capítulos donde se resumen los conocimientos sobre imagen PET, y especialmente aquellos relacionados con la técnica TOF-PET. Algunos trabajos recientes, pero aún no publicados se muestran también, con el objetivo de corroborar ciertas ideas. En la segunda parte se incluyen las cuatro contribuciones que el candidato sugiere para el compendio de artículos.[CA] La Tomografia per Emissió de Positrons (PET) és una de les tècniques més importants en la medicina de diagnòstic actual i la més representativa en el camp de la Imatge Molecular. Esta modalitat d'imatge és capaç de produir informació funcional única, que permet la visualització en detall, quantificació i coneixement d'una varietat de malalties i patologies. Àrees com l'oncologia, neurologia o la cardiologia, entre altres, s'han beneficiat en gran manera d'aquesta tècnica. Tot i que un elevat nombre d'avanços han ocorregut durant el desenvolupament del PET, hi ha altres que són de gran interés per a futures investigacions. Un dels principals pilars actuals en PET, tant en investigació com en desenvolupament, és l'obtenció de la informació del temps de vol (TOF en anglès) dels raigs gamma detectats. Quan açò ocorre, augmenta la sensibilitat efectiva del PET, millorant la qualitat senyal-soroll de les imatges. No obstant això, l'obtenció precisa de la marca temporal dels raigs gamma és un repte que requerix, a més de tècniques i mètodes específics, compromisos entre cost i rendiment. Una de les característiques que sempre es veu afectada és la resolució espacial. Com discutirem, la resolució espacial està directament relacionada amb el tipus de centellador, i per tant, amb el cost del sistema i la seua complexitat. En aquesta tesi, motivada pels coneguts beneficis en imatge clínica d'una mesura precisa del temps i de la posició dels raigs gamma, proposem nouves configuracions de detectors TOF-PET capaços de proveir d'ambduess característiques. Suggerim l'ús del que es coneix com a mètodes de "light-sharing", tant basat en cristalls monolítics com pixelats de diferent tamany del fotosensor. Aquestes propostes fan que la resolució espacial siga molt alta. No obstant això, les seues capacitats temporals han sigut molt poc abordades fins ara. En aquesta tesi, a través de diversos articles revisats, pretenem mostrar els reptes trobats en aquesta direcció, proposar determinades configuracions i, a més, indagar en els límits temporals d'aquestes. Hem posat un gran èmfasi a estudiar i analitzar les distribucions de la llum centellejant, així com el seu impacte en la determinació temporal. Fins al nostre coneixement, aquest és el primer treball en què s'estudia la relació de la determinació temporal i la distribució de llum de centelleig, en particular utilitzant SiPM analògics i ASICs. Esperem que aquesta tesi motive i permeta molts altres treballs orientats en nous dissenys, útils per a instrumentació PET, així com referència per a altres treballs. Aquesta tesi esta organitzada com es descriu a continuació. Hi ha una introducció composta per tres capítols on es resumeixen els coneixements sobre imatge PET i, especialmente, aquells relacionats amb la tècnica TOF-PET. Alguns treballs recents, però encara no publicats es mostren també, amb l'objectiu de corroborar certes idees. La segona part de la tesi conté els quatre articles revisats que el candidat suggereix.[EN] Positron Emission Tomography (PET) is one of the greatest tools of modern diagnostic medicine and the most representative in the field of molecular imaging. This imaging modality, is capable of providing a unique type of functional information which permits a deep visualization, quantification and understanding of a variety of diseases and pathologies. Areas like oncology, neurology, or cardiology, among others, have been well benefited by this technique. Although numerous important advances have already been achieved in PET, some other individual aspects still seem to have a great potential for further investigation. One of the main trends in modern PET research and development, is based in the extrapolation of the Time- Of-Flight (TOF) information from the gamma-ray detectors. In such case, an increase in the effective sensitivity of PET is accomplished, resulting in an improved image signal-to-noise ratio. However, the direction towards a precise decoding of the photons time arrival is a challenging task that requires, besides specific approaches and techniques, tradeoffs between cost and performance. A performance characteristic very habitually compromised in TOF-PET detector configurations is the spatial resolution. As it will be discussed, this feature is directly related to the scintillation materials and types, and consequently, with system cost and complexity. In this thesis, motivated by the well-known benefits in clinical imaging of a precise time and spatial resolution, we propose novel TOF-PET detector configurations capable of inferring both characteristics. Our suggestions are based in light sharing approaches, either using monolithic detectors or crystal arrays with different pixel-to-photosensor sizes. These approaches, make it possible to reach a precise impact position determination. However, their TOF capabilities have not yet been explored in depth. In the present thesis, through a series of peer-reviewed publications we attempt to demonstrate the challenges encountered in these kinds of configurations, propose specific approaches improving their performance and eventually reveal their limits in terms of timing. High emphasis is given in analyzing and studying the scintillation light distributions and their impact to the timing determination. To the best of our knowledge, this is one of the first works in which such detailed study of the relation between light distribution and timing capabilities is carried out, especially when using analog SiPMs and ASICs. Hopefully, this thesis will motivate and enable many other novel design concepts, useful in PET instrumentation as well as it will serve as a helpful reference for similar attempts. The present PhD thesis is organized as follows. There is an introduction part composed by three detailed sections. We attempt to summarize here some of the knowledge related to PET imaging and especially with the technique of TOF-PET. Some very recent but still unpublished results are also presented and included in this part, aiming to support statements and theories. The second part of this thesis lists the four peer-reviewed papers that the candidate is including.This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation program (grant agreement No 695536). It has also been supported by the Spanish Ministerio de Economía, Industria y Competitividad under Grants No. FIS2014-62341-EXP and TEC2016-79884-C2-1-R. Efthymios Lamprou has also been supported by Generalitat Valenciana under grant agreement GRISOLIAP-2018-026.Lamprou, E. (2021). Development and Performance Evaluation of High Resolution TOF-PET Detectors Suitable for Novel PET Scanners [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/162991TESISCompendi

    Application of novel technologies for the development of next generation MR compatible PET inserts

    Get PDF
    Multimodal imaging integrating Positron Emission Tomography and Magnetic Resonance Imaging (PET/MRI) has professed advantages as compared to other available combinations, allowing both functional and structural information to be acquired with very high precision and repeatability. However, it has yet to be adopted as the standard for experimental and clinical applications, due to a variety of reasons mainly related to system cost and flexibility. A hopeful existing approach of silicon photodetector-based MR compatible PET inserts comprised by very thin PET devices that can be inserted in the MRI bore, has been pioneered, without disrupting the market as expected. Technological solutions that exist and can make this type of inserts lighter, cost-effective and more adaptable to the application need to be researched further. In this context, we expand the study of sub-surface laser engraving (SSLE) for scintillators used for PET. Through acquiring, measuring and calibrating the use of a SSLE setting we study the effect of different engraving configurations on detection characteristics of the scintillation light by the photosensors. We demonstrate that apart from cost-effectiveness and ease of application, SSLE treated scintillators have similar spatial resolution and superior sensitivity and packing fraction as compared to standard pixelated arrays, allowing for shorter crystals to be used. Flexibility of design is benchmarked and adoption of honeycomb architecture due to geometrical advantages is proposed. Furthermore, a variety of depth-of-interaction (DoI) designs are engraved and studied, greatly enhancing applicability in small field-of-view tomographs, such as the intended inserts. To adapt to this need, a novel approach for multi-layer DoI characterization has been developed and is demonstrated. Apart from crystal treatment, considerations on signal transmission and processing are addressed. A double time-over-threshold (ToT) method is proposed, using the statistics of noise in order to enhance precision. This method is tested and linearity results demonstrate applicability for multiplexed readout designs. A study on analog optical wireless communication (aOWC) techniques is also performed and proof of concept results presented. Finally, a ToT readout firmware architecture, intended for low-cost FPGAs, has been developed and is described. By addressing the potential development, applicability and merits of a range of transdisciplinary solutions, we demonstrate that with these techniques it is possible to construct lighter, smaller, lower consumption, cost-effective MRI compatible PET inserts. Those designs can make PET/MRI multimodality the dominant clinical and experimental imaging approach, enhancing researcher and physician insight to the mysteries of life.La combinación multimodal de Tomografía por Emisión de Positrones con la Imagen de Resonancia Magnética (PET/MRI, de sus siglas en inglés) tiene clara ventajas en comparación con otras técnicas multimodales actualmente disponibles, dada su capacidad para registrar información funcional e información estructural con mucha precisión y repetibilidad. Sin embargo, esta técnica no acaba de penetrar en la práctica clínica debido en gran parte a alto coste. Las investigaciones que persiguen mejorar el desarrollo de insertos de PET basados en fotodetectores de silicio y compatibles con MRI, aunque han sido intensas y han generado soluciones ingeniosas, todavía no han conseguido encontrar las soluciones que necesita la industria. Sin embargo, existen opciones todavía sin explorar que podrían ayudar a evolucionar este tipo de insertos consiguiendo dispositivos más ligeros, baratos y con mejores prestaciones. Esta tesis profundiza en el estudio de grabación sub-superficie con láser (SSLE) para el diseño de los cristales centelladores usados en los sistemas PET. Para ello hemos caracterizado, medido y calibrado un procedimiento SSLE, y a continuación hemos estudiado el efecto que tienen sobre las especificaciones del detector las diferentes configuraciones del grabado. Demostramos que además de la rentabilidad y facilidad de uso de esta técnica, los centelladores SSLE tienen resolución espacial equivalente y sensibilidad y fracción de empaquetamiento superiores a las matrices de centelleo convencionales, lo que posibilita utilizar cristales más cortos para conseguir la misma sensibilidad. Estos diseños también permiten medir la profundidad de la interacción (DoI), lo que facilita el uso de estos diseños en tomógrafos de radio pequeño, como pueden ser los sistemas preclínicos, los dedicados (cabeza o mama) o los insertos para MRI. Además de trabajar en el tratamiento de cristal de centelleo, hemos considerado nuevas aproximaciones al procesamiento y transmisión de la señal. Proponemos un método innovador de doble medida de tiempo sobre el umbral (ToT) que integra una evaluación de la estadística del ruido con el propósito de mejorar la precisión. El método se ha validado y los resultados demuestran su viabilidad de uso incluso en conjuntos de señales multiplexadas. Un estudio de las técnicas de comunicación óptica analógica e inalámbrica (aOWC) ha permitido el desarrollo de una nueva propuesta para comunicar las señales del detector PET insertado en el gantry a un el procesador de señal externo, técnica que se ha validado en un demostrador. Finalmente, se ha propuesto y demostrado una nueva arquitectura de análisis de señal ToT implementada en firmware en FPGAs de bajo coste. La concepción y desarrollo de estas ideas, así como la evaluación de los méritos de las diferentes soluciones propuestas, demuestran que con estas técnicas es posible construir insertos de PET compatibles con sistemas MRI, que serán más ligeros y compactos, con un reducido consumo y menor coste. De esta forma se contribuye a que la técnica multimodal PET/MRI pueda penetrar en la clínica, mejorando la comprensión que médicos e investigadores puedan alcanzar en su estudio de los misterios de la vida.Programa Oficial de Doctorado en Ingeniería Eléctrica, Electrónica y AutomáticaPresidente: Andrés Santos Lleó.- Secretario: Luis Hernández Corporales.- Vocal: Giancarlo Sportell

    Simulation of Clinical PET Studies for the Assessment of Quantification Methods

    Get PDF
    On this PhD thesis we developed a methodology for evaluating the robustness of SUV measurements based on MC simulations and the generation of novel databases of simulated studies based on digital anthropomorphic phantoms. This methodology has been applied to different problems related to quantification that were not previously addressed. Two methods for estimating the extravasated dose were proposed andvalidated in different scenarios using MC simulations. We studied the impact of noise and low counting in the accuracy and repeatability of three commonly used SUV metrics (SUVmax, SUVmean and SUV50). The same model was used to study the effect of physiological muscular uptake variations on the quantification of FDG-PET studies. Finally, our MC models were applied to simulate 18F-fluorocholine (FCH) studies. The aim was to study the effect of spill-in counts from neighbouring regions on the quantification of small regions close to high activity extended sources

    Compendium of Applications Technology Satellite user experiments

    Get PDF
    The achievements of the user experiments performed with ATS satellites from 1967 to 1973 are summarized. Included are fixed and mobile point to point communications experiments involving voice, teletype and facsimile transmissions. Particular emphasis is given to the Alaska and Hawaii satellite communications experiments. The use of the ATS satellites for ranging and position fixing of ships and aircraft is also covered. The structure and operating characteristics of the various ATS satellite are briefly described

    Paramètres de conception optimaux pour maximiser le rapport contraste à bruit pour scanners TEP avec temps de vol

    Get PDF
    Abstract : Time-of-flight (TOF) positron emission tomography (PET) scanners improve contrast-tonoise ratio (CNR) that translates into reducing the scan time or the required injected dose. During the past years, TOF PET has evolved towards temporal resolutions of the order of 200 ps, corresponding to a spatial uncertainty of 30 mm along the line of response (LOR) defined by the two annihilation photons. Although this location uncertainty is sufficient to improve the effective sensitivity of clinical scanners, resolving small size tissues such as a lymph node, or small animal organs would require the timing performance to be less than 50 ps to resolve objects smaller than ⇠ 10 mm. A coincidence time resolution around 10 ps would even allow to avoid tomographic reconstruction of PET images. Obtaining good image performance in PET demands tackling simultaneously all image quality parameters, including spatial resolution, sensitivity, and CNR. However, this involves difficult trade-offs as studies have demonstrated that choices made at the design level for the detector configuration may enhance some image quality parameters but are then detrimental to others. It is therefore mandatory to identify and carefully investigate the factors contributing to the CNR, one of the most important parameter for image quality. One such factor is the choice of crystal thickness that affects coincidence time resolution and thus CNR. Although improved coincidence time resolution increases the chance of small lesion detectability, trade-offs should be studied to find an optimum compromise maximizing the image performance. The motivation underlying this research is to determine the limit where TOF adds gain in small animal PET imaging and also investigate trade-offs between crystal length, timing resolution, and sensitivity to find the optimum image quality. These trade-offs target the coincidence time resolution improvement to enhance CNR performance without compromising the other parameters of image quality. It is demonstrated that a coincidence time resolution of 100 ps is the threshold where TOF starts to improve the image performance of a small animal scanner. In addition, it is shown that the crystal thickness can be reduced by 19 % without loss on the imaging performance. A model is also proposed that describes the CNR performance with a relatively high level of confidence at early stages of the design, and can be used as a guide to design the future generation of scanners. This is followed by introducing a new phantom purposely designed to study TOF benefits and impacts on lesion detectability for PET scanners.Les scanners de tomographie d’émission par positrons (TEP) par temps de vol (TdV) augmentent le rapport contraste à bruit (RCB) en réduisant le bruit de fond. Ceci se traduit par un temps d’acquisition plus court ou une dose réduite. Au cours des années, la TEP-TdV a évolué vers des résolutions temporelles de l’ordre de 200 ps, ce qui correspond à une incertitude spatiale de 30 mm. Bien que cela soit suffisant pour améliorer la sensibilité effective des scanners cliniques, résoudre des petites structures comme les ganglions lymphatiques, ou des organes de petits animaux nécessite des résolutions temporelles inférieures à 50 ps pour résoudre un objet inférieur à ∼ 10 mm. Une résolution temporelle de 10 mm permettrait même d’éviter la reconstruction tomographique des images TEP. L’obtention d’une bonne performance d’image en TEP nécessite d’aborder simultanément tous les paramètres de qualité d’image, y compris la résolution spatiale, la sensibilité et le RCB. Cependant, il est peu probable que cela se produise, car des études ont démontré que les choix de conception du détecteur peuvent favoriser certains paramètres de qualité d’image, mais en dégrader d’autres. On doit donc cibler les facteurs contribuant au RCB, l’un des paramètres importants de la qualité d’image. Un de ces facteurs est le choix de l’épaisseur du cristal qui affecte la résolution temporelle et donc, le RCB. Bien qu’une résolution temporelle améliorée augmente la détectabilité des petites lésions, on doit étudier les compromis afin de trouver un point d’équilibre offrant à la meilleure performance d’image possible. La motivation de cette recherche est de déterminer la limite à partir de laquelle le TdV améliore la qualité de l’imagerie des petits animaux et également, d’étudier les compromis nécessaires entre la longueur des cristaux, la résolution temporelle et la sensibilité pour atteindre la qualité d’image optimale. Ces compromis ciblent l’amélioration de la résolution temporelle pour améliorer les performances du RCB sans compromettre les autres paramètres de qualité d’image. Ces travaux démontrent qu’une résolution temporelle de 100 ps est le seuil à partir duquel le TdV améliore le performance RBC de l’imagerie des petits animaux. De plus, ils montrent que le volume du cristal peut être réduit de 19 % sans détériorer l’image. Un modèle est également proposé pour prédire le RCB avec un niveau de confiance relativement élevé et il peut être utilisé comme guide pour concevoir la prochaine génération de scanners. L’introduction d’une nouvelle mire élaborée pour étudier les avantages et les impacts du TdV sur la détectabilité des lésions pour les scanners TdV est par la suite présentée
    corecore