    A Novel Low Noise High Gain CMOS Instrumentation Amplifier for Biomedical Applications

    Get PDF
    This work describes a novel technique of designing a low noise high gain CMOS instrumentation amplifier for biomedical applications. A three op-amp instrumentation amplifier have been designed by employing two simple op-amps at the two inputs and a folded cascode op-amp at the output. Both input and output stage op-amps are 2-stage. Most of the earlier designed op-amp in literature uses same type of op-amp at the input and output stages of instrumentation amplifier. By using folded cascode two stage op-amp at the output, we have achieved significant improvement in gain and CMRR. Transistors sizing plays a vital role in achieving high gain and CMRR. To achieve a desirable gain, common mode rejection ratio and other performance metrics, selection of most appropriate op-amp circuit topologies & optimum transistor sizing was the main criteria for design of instrumentation amplifier for biomedical applications. The instrumentation amplifier is simulated using Cadence Spectre tool and layout is designed in Cadence Layout editor at 0.18µm CMOS technology. Each of the input op-amp provides a gain and CMRR of 45dB and 72dB respectively. The output stage folded cascode amplifier provides a gain of 82dB and a CMRR of 92dB. The design achieves an overall gain and CMRR of 67dB and 92db respectively. The designed instrumentation amplifier consumes only 263µW of power suitable for biomedical signal processing applications.DOI:http://dx.doi.org/10.11591/ijece.v3i4.317

    A neural probe with up to 966 electrodes and up to 384 configurable channels in 0.13 μm SOI CMOS

    Get PDF
    In vivo recording of neural action-potential and local-field-potential signals requires the use of high-resolution penetrating probes. Several international initiatives to better understand the brain are driving technology efforts towards maximizing the number of recording sites while minimizing the neural probe dimensions. We designed and fabricated (0.13-μm SOI Al CMOS) a 384-channel configurable neural probe for large-scale in vivo recording of neural signals. Up to 966 selectable active electrodes were integrated along an implantable shank (70 μm wide, 10 mm long, 20 μm thick), achieving a crosstalk of −64.4 dB. The probe base (5 × 9 mm2) implements dual-band recording and a 1

    Low-Power Instrumentation Amplifier IC Design for ECG System Applications

    Get PDF
    AbstractThis paper describes the development of a low-power instrumentation amplifier (IA) intended for use in recording of the human electrocardiogram (ECG). With the wide-swing cascade bias circuit design, the IA realizes a very high power-supply rejection ratio (PSRR), and can be operated at signal supply voltage in the rage between 2.5 and 5.5 V. It was fabricated using 0.5um double-poly triple-metal CMOS technology, and occupies a die area of 0.2mm2.The amplifier provides a gain of 40 dB and has high common-mode rejection ration (CMRR) better than 100 dB. The IA has a power consumption of 160uW operating from a 3.3 V power supply

    A Power-Efficient Bio-Potential Acquisition Device with DS-MDE Sensors for Long-Term Healthcare Monitoring Applications

    Get PDF
    This work describes a power-efficient bio-potential acquisition device for long-term healthcare applications that is implemented using novel microelectromechanical dry electrodes (MDE) and a low power bio-potential processing chip. Using micromachining technology, an attempt is also made to enhance the sensing reliability and stability by fabricating a diamond-shaped MDE (DS-MDE) that has a satisfactory self-stability capability and superior electric conductivity when attached onto skin without any extra skin tissue injury technology. To acquire differential bio-potentials such as ECG signals, the proposed processing chip fabricated in a standard CMOS process has a high common mode rejection ratio (C.M.R.R.) differential amplifier and a 12-bit analog-to-digital converter (ADC). Use of the proposed system and integrate simple peripheral commercial devices can obtain the ECG signal efficiently without additional skin tissue injury and ensure continuous monitoring more than 70 hours with a 400 mAh battery

    Low Power CMOS Electrocardiogram Amplifier Design for Wearable Cardiac Screening

    Get PDF
    The trend of health care screening devices in the world is increasingly towards the favor of portability and wearability. This is because these wearable screening devices are not restricting the patient’s freedom and daily activities. While the demand of low power and low cost biomedical system on chip is increasing in exponential way, the front-end electrocardiogram (ECG) amplifiers are still suffering from flicker noise for low frequency cardiac signal acquisition, 50Hz power line electromagnetic interference, and the large unstable input offsets due to the electrode-skin interface is not attached properly. In this paper, a CMOS based ECG amplifier that suitable for low power wearable cardiac screening is proposed. The amplifier adopts the highly stable folded cascode topology and later being implemented into RC feedback circuit for low frequency DC offset cancellation. By using  0.13µm CMOS technology from Silterra, the simulation results show that this front-end circuit can achieve a very low input referred noise of  1pV/Hz1/2 and high common mode rejection ratio of 174.05dB. It also gives voltage gain of 75.45dB with good power supply rejection ratio of 92.12dB. The total power consumption is only 3µW and thus suitable to be implemented with further signal processing and classification back end for low power wearable biomedical device

    Amplifiers in Biomedical Engineering: A Review from Application Perspectives

    Get PDF
    Continuous monitoring and treatment of various diseases with biomedical technologies and wearable electronics has become significantly important. The healthcare area is an important, evolving field that, among other things, requires electronic and micro-electromechanical technologies. Designed circuits and smart devices can lead to reduced hospitalization time and hospitals equipped with high-quality equipment. Some of these devices can also be implanted inside the body. Recently, various implanted electronic devices for monitoring and diagnosing diseases have been presented. These instruments require communication links through wireless technologies. In the transmitters of these devices, power amplifiers are the most important components and their performance plays important roles. This paper is devoted to collecting and providing a comprehensive review on the various designed implanted amplifiers for advanced biomedical applications. The reported amplifiers vary with respect to the class/type of amplifier, implemented CMOS technology, frequency band, output power, and the overall efficiency of the designs. The purpose of the authors is to provide a general view of the available solutions, and any researcher can obtain suitable circuit designs that can be selected for their problem by reading this survey

    A New Proposal for OFCC-based Instrumentation Amplifier

    Get PDF
    This contribution puts forward a new voltage mode instrumentation amplifier (VMIA) based on operational floating current conveyor (OFCC). It presents high impedance at input terminals and provides output at low impedance making the proposal ideal for voltage mode operation. The proposed VMIA architecture has two stages - the first stage comprises of two OFCCs to sense input voltages and coverts the voltage difference to current while the second stage has single OFCC that converts the current to voltage. In addition it employs two resistors to provide gain and imposes no condition on the values of resistors.  The behavior of the proposed structure is also analyzed for OFCC non idealities namely finite transimpedance and tracking error. The proposal is verified through SPICE simulations using CMOS based schematic of OFCC. Experimental results, by bread boarding it using commercially available IC AD844, are also included

    CMRR Boosted Instrumentation Amplifier for Biomedical Application

    Get PDF
    This research paper discusses about a design of an amplifier for its use in an Analog Front End for Biomedical signal acquisition. The design of an AFE is also specific to the signal of interest. This paper deals with the design of an Analog Front End using 180nm process. An amplifier is a key component of an AFE. For instrumentation amplifier to satisfy theoretical results the OPAMP used must be close to ideal. The simulations are performed using TANNER EDA tool

    Low-Noise Micro-Power Amplifiers for Biosignal Acquisition

    Get PDF
    There are many different types of biopotential signals, such as action potentials (APs), local field potentials (LFPs), electromyography (EMG), electrocardiogram (ECG), electroencephalogram (EEG), etc. Nerve action potentials play an important role for the analysis of human cognition, such as perception, memory, language, emotions, and motor control. EMGs provide vital information about the patients which allow clinicians to diagnose and treat many neuromuscular diseases, which could result in muscle paralysis, motor problems, etc. EEGs is critical in diagnosing epilepsy, sleep disorders, as well as brain tumors. Biopotential signals are very weak, which requires the biopotential amplifier to exhibit low input-referred noise. For example, EEGs have amplitudes from 1 μV [microvolt] to 100 μV [microvolt] with much of the energy in the sub-Hz [hertz] to 100 Hz [hertz] band. APs have amplitudes up to 500 μV [microvolt] with much of the energy in the 100 Hz [hertz] to 7 kHz [hertz] band. In wearable/implantable systems, the low-power operation of the biopotential amplifier is critical to avoid thermal damage to surrounding tissues, preserve long battery life, and enable wirelessly-delivered or harvested energy supply. For an ideal thermal-noise-limited amplifier, the amplifier power is inversely proportional to the input-referred noise of the amplifier. Therefore, there is a noise-power trade-off which must be well-balanced by the designers. In this work I propose novel amplifier topologies, which are able to significantly improve the noise-power efficiency by increasing the effective transconductance at a given current. In order to reject the DC offsets generated at the tissue-electrode interface, energy-efficient techniques are employed to create a low-frequency high-pass cutoff. The noise contribution of the high-pass cutoff circuitry is minimized by using power-efficient configurations, and optimizing the biasing and dimension of the devices. Sufficient common-mode rejection ratio (CMRR) and power supply rejection ratio (PSRR) are achieved to suppress common-mode interferences and power supply noises. Our design are fabricated in standard CMOS processes. The amplifiers’ performance are measured on the bench, and also demonstrated with biopotential recordings

    A 5.5 μW 42nV/√Hz Chopper stabilized Amplifier for Biomedical Application with Input Impedance Enhancement

    Get PDF
    The continuous real-time monitoring of diverse physical parameters using biosignals like ECG and EEG requires the biomedical sensors. Such sensor consists of analog frontend unit for which low noise and low power Operational transconductance amplifier (OTA) is essential. In this paper, the novel chopper-stabilized bio-potential amplifier is proposed. The chopper stabilization technique is used to reduce the offset and flicker noise. Further, the OTA is likewise comprised of a method to enhance the input impedance without consuming more power. Also, the ripple reduction technique is used at the output branch of the OTA. The designed amplifier consumes 5.5 μW power with the mid-band gain of 40dB. The pass-band for the designed amplifier is 0.1Hz to 1KHz. The input impedance is likewise boosted with the proposed method. The noise is 42 nV/√Hz with CMRR of 82 dB. All simulations are carried out in 180nm parameters