58,838 research outputs found
Detection of dirt impairments from archived film sequences : survey and evaluations
Film dirt is the most commonly encountered artifact in archive restoration applications. Since dirt usually appears as a temporally impulsive event, motion-compensated interframe processing is widely applied for its detection. However, motion-compensated prediction requires a high degree of complexity and can be unreliable when motion estimation fails. Consequently, many techniques using spatial or spatiotemporal filtering without motion were also been proposed as alternatives. A comprehensive survey and evaluation of existing methods is presented, in which both qualitative and quantitative performances are compared in terms of accuracy, robustness, and complexity. After analyzing these algorithms and identifying their limitations, we conclude with guidance in choosing from these algorithms and promising directions for future research
Magnetometry with nitrogen-vacancy defects in diamond
The isolated electronic spin system of the Nitrogen-Vacancy (NV) centre in
diamond offers unique possibilities to be employed as a nanoscale sensor for
detection and imaging of weak magnetic fields. Magnetic imaging with nanometric
resolution and field detection capabilities in the nanotesla range are enabled
by the atomic-size and exceptionally long spin-coherence times of this
naturally occurring defect. The exciting perspectives that ensue from these
characteristics have triggered vivid experimental activities in the emerging
field of "NV magnetometry". It is the purpose of this article to review the
recent progress in high-sensitivity nanoscale NV magnetometry, generate an
overview of the most pertinent results of the last years and highlight
perspectives for future developments. We will present the physical principles
that allow for magnetic field detection with NV centres and discuss first
applications of NV magnetometers that have been demonstrated in the context of
nano magnetism, mesoscopic physics and the life sciences.Comment: Review article, 28 pages, 16 figure
High Resolution Microimaging with Pulsed Electrically-Detected Magnetic Resonance
The investigation of paramagnetic species (such as point defects, dopants,
and impurities) in solid-state electronic devices is significant because of
their effect on device performance. Conventionally, these species are detected
and imaged using the electron spin resonance (ESR) technique. In many
instances, ESR is not sensitive enough to deal with miniature devices having
small numbers of paramagnetic species and high spatial heterogeneity. This
limitation can in principle be overcome by employing a more sensitive method
called electrically-detected magnetic resonance, which is based on measuring
the effect of paramagnetic species on the electric current of the device while
inducing electron spin-flip transitions. However, up until now, measurement of
the current of the device could not reveal the spatial heterogeneity of its
paramagnetic species. We provide here, for the first time, high resolution
microimages of paramagnetic species in operating solar cells obtained through
electrically-detected magnetic resonance. The method is based on unique
microwave pulse sequences for excitation and detection of the electrical signal
under a static magnetic field and powerful pulsed magnetic field gradients that
spatially encode the electrical current of the sample. The approach developed
here can be widely used in the nondestructive three-dimensional inspection and
characterization of paramagnetic species in a variety of electronic devices.Comment: 19 pages, 4 figures +S
Gravity optimised particle filter for hand tracking
This paper presents a gravity optimised particle filter (GOPF) where the magnitude of the gravitational force for every particle is proportional to its weight. GOPF attracts nearby particles and replicates new particles as if moving the particles towards the peak of the likelihood distribution, improving the sampling efficiency. GOPF is incorporated into a technique for hand features tracking. A fast approach to hand features detection and labelling using convexity defects is also presented. Experimental results show that GOPF outperforms the standard particle filter and its variants, as well as state-of-the-art CamShift guided particle filter using a significantly reduced number of particles
Multi-scale gapped smoothing algorithm for robust baseline-free damage detection in optical infrared thermography
Flash thermography is a promising technique to perform rapid non-destructive testing of composite materials. However, it is well known that several difficulties are inherently paired with this approach, such as non-uniform heating, measurement noise and lateral heat diffusion effects. Hence, advanced signal-processing techniques are indispensable in order to analyze the recorded dataset. One such processing technique is Gapped Smoothing Algorithm, which predicts a gapped pixel’s value in its sound state from a measurement in the defected state by evaluating only its neighboring pixels. However, the standard Gapped Smoothing Algorithm uses a fixed spatial gap size, which induces issues to detect variable defect sizes in a noisy dataset.
In this paper, a Multi-Scale Gapped Smoothing Algorithm (MSGSA) is introduced as a baseline-free image processing technique and an extension to the standard Gapped Smoothing Algorithm. The MSGSA makes use of the evaluation of a wide range of spatial gap sizes so that defects of highly different dimensions are identified. Moreover, it is shown that a weighted combination of all assessed spatial gap sizes significantly improves the detectability of defects and results in an (almost) zero-reference background. The technique thus effectively suppresses the measurement noise and excitation non-uniformity. The efficiency of the MSGSA technique is evaluated and confirmed through numerical simulation and an experimental procedure of flash thermography on carbon fiber reinforced polymers with various defect sizes
MRI of the lung (3/3)-current applications and future perspectives
BACKGROUND: MRI of the lung is recommended in a number of clinical indications. Having a non-radiation alternative is particularly attractive in children and young subjects, or pregnant women. METHODS: Provided there is sufficient expertise, magnetic resonance imaging (MRI) may be considered as the preferential modality in specific clinical conditions such as cystic fibrosis and acute pulmonary embolism, since additional functional information on respiratory mechanics and regional lung perfusion is provided. In other cases, such as tumours and pneumonia in children, lung MRI may be considered an alternative or adjunct to other modalities with at least similar diagnostic value. RESULTS: In interstitial lung disease, the clinical utility of MRI remains to be proven, but it could provide additional information that will be beneficial in research, or at some stage in clinical practice. Customised protocols for chest imaging combine fast breath-hold acquisitions from a "buffet" of sequences. Having introduced details of imaging protocols in previous articles, the aim of this manuscript is to discuss the advantages and limitations of lung MRI in current clinical practice. CONCLUSION: New developments and future perspectives such as motion-compensated imaging with self-navigated sequences or fast Fourier decomposition MRI for non-contrast enhanced ventilation- and perfusion-weighted imaging of the lung are discussed. Main Messages • MRI evolves as a third lung imaging modality, combining morphological and functional information. • It may be considered first choice in cystic fibrosis and pulmonary embolism of young and pregnant patients. • In other cases (tumours, pneumonia in children), it is an alternative or adjunct to X-ray and CT. • In interstitial lung disease, it serves for research, but the clinical value remains to be proven. • New users are advised to make themselves familiar with the particular advantages and limitations
- …