134,802 research outputs found

    Overload protection system for power inverter

    Get PDF
    An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely

    Developed cascaded multilevel inverter topology to minimise the number of circuit devices and voltage stresses of switches

    Get PDF
    In this study, a novel structure for cascade multilevel inverter is presented. The proposed inverter can generate all possible DC voltage levels with the value of positive and negative. The proposed structure results in reduction of switches number, relevant gate driver circuits and also the installation area and inverter cost. The suggested inverter can be used as symmetric and asymmetric structures. Comparing the peak inverse voltage and losses of the proposed inverter with conventional multilevel inverters show the superiority of the proposed converter. The operation and good performance of the proposed multilevel inverter have been verified by the simulation results of a single-phase nine-level symmetric and 17-level asymmetric multilevel inverter and experimental results of a nine-level and 17-level inverters. Simulation and experimental results confirmed the validity and effectiveness performance of the proposed inverter

    Comparison between unipolar and bipolar single phase grid-connected inverters for PV applications

    Get PDF
    An inverter is essential for the interfacing of photovoltaic panels with the AC network. There are many possible inverter topologies and inverter switching schemes and each one will have its own relative advantages and disadvantages. Efficiency and output current distortion are two important factors governing the choice of inverter system. In this paper, it is argued that current controlled inverters offer significant advantages from the point of view of minimisation of current distortion. Two inverter switching strategies are explored in detail. These are the unipolar current controlled inverter and the bipolar current controlled inverter. With respect to low frequency distortion, previously published works provide theoretical arguments in favour of bipolar switching. On the other hand it has also been argued that the unipolar switched inverter offers reduced switching losses and generates less EMI. On efficiency grounds, it appears that the unipolar switched inverter has an advantage. However, experimental results presented in this paper show that the level of low frequency current distortion in the unipolar switched inverter is such that it can only comply with Australian Standard 4777.2 above a minimum output current. On the other hand it is shown that at the same current levels bipolar switching results in reduced low frequency harmonics

    Comparison between unipolar and bipolar single phase grid-connected inverters for PV applications

    Get PDF
    An inverter is essential for the interfacing of photovoltaic panels with the AC network. There are many possible inverter topologies and inverter switching schemes and each one will have its own relative advantages and disadvantages. Efficiency and output current distortion are two important factors governing the choice of inverter system. In this paper, it is argued that current controlled inverters offer significant advantages from the point of view of minimisation of current distortion. Two inverter switching strategies are explored in detail. These are the unipolar current controlled inverter and the bipolar current controlled inverter. With respect to low frequency distortion, previously published works provide theoretical arguments in favour of bipolar switching. On the other hand it has also been argued that the unipolar switched inverter offers reduced switching losses and generates less EMI. On efficiency grounds, it appears that the unipolar switched inverter has an advantage. However, experimental results presented in this paper show that the level of low frequency current distortion in the unipolar switched inverter is such that it can only comply with Australian Standard 4777.2 above a minimum output current. On the other hand it is shown that at the same current levels bipolar switching results in reduced low frequency harmonics

    Multilevel single phase isolated inverter with reduced number of switches

    Get PDF
    This paper proposes a cascaded single phase multilevel inverter using an off-the-shelf three-phase inverter and transformer. The concept is based on a cascaded connection of two inverter legs using a typical three phase inverter in such a way that the third leg is shared between the other two phases. The cascaded connection is achieved through an integrated series transformer with a typical three-phase transformer core. Utilization of a special transformer design has been previously proposed in the Custom Power Active Transformer. However, cascaded connection of inverter legs has not been previously investigated with such a concept. In this way, a three-leg inverter and a three-phase transformer are converted into an isolated multilevel single-phase inverter based on an unique configuration and modulation technique.Postprint (author's final draft

    Self-Commissioning of Inverter Nonlinear Effects in AC Drives

    Get PDF
    The paper presents a novel technique for an accurate identification of the inverter nonlinear effects, such as the dead-time and on-state voltage drops. The proposed technique is very simple and it is based only on a current control scheme. If the inverter load is an AC motor, the inverter effects can be identified at drive startup using as measured quantities the motor currents and the inverter DC link voltage. The identified inverter error is stored in a Look-Up Table (LUT) that can be subsequently used by the vector control algorithm. The proposed method has been tested on a 1 kVA inverter prototype and the obtained results demonstrate the feasibility of the proposed solutio

    A Control Method for Static VAR Compensator Based On Modular Multilevel Inverter

    Get PDF
    Multilevel inverters are promised to provide a better performance in high power applications such as static VAR compensators. The proposed modular inverter has advantages compared to the conventional technologies. A control system of static VAR compensator using new modular multilevel inverter is proposed in this paper. Modeling and dynamic performance of static VAR compensator based on the proposed multilevel inverter are described in this paper. The inverter switching devices are switched at the fundamental output frequency. How to control the dc capacitor voltage is described. Several simulated results are included to verify the proposed concept. Keywords: Multilevel, inverter, STATCO

    A Fault-Tolerant T-Type Multilevel Inverter Topology With Increased Overload Capability and Soft-Switching Characteristics

    Get PDF
    he performance of a novel three-phase four-leg fault-tolerant T-type inverter topology is introduced in this paper. This inverter topology provides a fault-tolerant solution to any open-circuit and certain short-circuit switching faults in the power devices. During any of the fault-tolerant operation modes for these device faults, there is no derating required in the inverter output voltage or output power. In addition, overload capability is increased in this new T-type inverter compared to that in the conventional three-level T-type inverter. Such increase in inverter overload capability is due to the utilization of the redundant leg for overload current sharing with other main phase legs under healthy condition. Moreover, if the redundant phase leg is composed of silicon carbide metal-oxide-semiconductor field-effect transistors, quasi-zero-voltage switching, and zero-current switching of the silicon insulated-gate bipolar transistors (IGBTs) in the conventional main phase legs can be achieved at certain switching states, which can significantly relieve the thermal stress on the outer IGBTs and improve the whole inverter efficiency. Simulation and experimental results are given to verify the efficacy and merits of this high-performance fault-tolerant T-type inverter topology

    The implementation of sinusoidal PWM on single phase 5-level cascaded H-bridge multilevel inverter

    Get PDF
    In the new millennium era of technology, modern industrial devices are mostly based on electronic devices that are very sensitive to harmonics. The needs for a free-harmonics and high rating power source is extremely increased in the past few years to meet the requirement from the industries. An inverter which converts DC power to AC power is one of the power electronic devices that have been in the researchers’ radar for further improvement to generate a clean power source. An inverter can be broadly classified into single level inverter and multilevel inverter. A multilevel inverter as compared to a single level inverter has advantages like minimum harmonics distortion and higher power output. An implementation of cascaded h-bridge topology and a sinusoidal pulse�width modulation, synthesize a higher quality output power especially with multilevel configuration

    Design and Analysis of Three-Phase Three-Level PWM Inverter

    Get PDF
    Design of three-phase three level PWM inverter and analysis of the output current harmonics are presented in this paper. The three-level inverter is designed to supply three-phase load and it is controlled by FPGA under several modulation techniques (Sinusoidal PWM and Third Harmonic Injection PWM). Selection of semiconductor switches and other component of the inverter are described. Inverter output current harmonics under several modulation techniques will be analysed and compared
    • …
    corecore