13,299 research outputs found
A Novel Framework for Highlight Reflectance Transformation Imaging
We propose a novel pipeline and related software tools for processing the multi-light image collections (MLICs) acquired in different application contexts to obtain shape and appearance information of captured surfaces, as well as to derive compact relightable representations of them. Our pipeline extends the popular Highlight Reflectance Transformation Imaging (H-RTI) framework, which is widely used in the Cultural Heritage domain. We support, in particular, perspective camera modeling, per-pixel interpolated light direction estimation, as well as light normalization correcting vignetting and uneven non-directional illumination. Furthermore, we propose two novel easy-to-use software tools to simplify all processing steps. The tools, in addition to support easy processing and encoding of pixel data, implement a variety of visualizations, as well as multiple reflectance-model-fitting options. Experimental tests on synthetic and real-world MLICs demonstrate the usefulness of the novel algorithmic framework and the potential benefits of the proposed tools for end-user applications.Terms: "European Union (EU)" & "Horizon 2020" / Action: H2020-EU.3.6.3. - Reflective societies - cultural heritage and European identity / Acronym: Scan4Reco / Grant number: 665091DSURF project (PRIN 2015) funded by the Italian Ministry of University and ResearchSardinian Regional Authorities under projects VIGEC and Vis&VideoLa
Modeling and interpolation of the ambient magnetic field by Gaussian processes
Anomalies in the ambient magnetic field can be used as features in indoor
positioning and navigation. By using Maxwell's equations, we derive and present
a Bayesian non-parametric probabilistic modeling approach for interpolation and
extrapolation of the magnetic field. We model the magnetic field components
jointly by imposing a Gaussian process (GP) prior on the latent scalar
potential of the magnetic field. By rewriting the GP model in terms of a
Hilbert space representation, we circumvent the computational pitfalls
associated with GP modeling and provide a computationally efficient and
physically justified modeling tool for the ambient magnetic field. The model
allows for sequential updating of the estimate and time-dependent changes in
the magnetic field. The model is shown to work well in practice in different
applications: we demonstrate mapping of the magnetic field both with an
inexpensive Raspberry Pi powered robot and on foot using a standard smartphone.Comment: 17 pages, 12 figures, to appear in IEEE Transactions on Robotic
Toward Early-Warning Detection of Gravitational Waves from Compact Binary Coalescence
Rapid detection of compact binary coalescence (CBC) with a network of
advanced gravitational-wave detectors will offer a unique opportunity for
multi-messenger astronomy. Prompt detection alerts for the astronomical
community might make it possible to observe the onset of electromagnetic
emission from (CBC). We demonstrate a computationally practical filtering
strategy that could produce early-warning triggers before gravitational
radiation from the final merger has arrived at the detectors.Comment: 16 pages, 7 figures, published in ApJ. Reformatted preprint with
emulateap
Design and Performance of the Wide-Field X-Ray Monitor on Board the High-Energy Transient Explorer 2
The Wide-field X-ray Monitor (WXM) is one of the scientific instruments
carried on the High Energy Transient Explorer 2 (HETE-2) satellite launched on
2000 October 9. HETE-2 is an international mission consisting of a small
satellite dedicated to provide broad-band observations and accurate
localizations of gamma-ray bursts (GRBs). A unique feature of this mission is
its capability to determine and transmit GRB coordinates in almost real-time
through the burst alert network. The WXM consists of three elements: four
identical Xe-filled one-dimensional position-sensitive proportional counters,
two sets of one-dimensional coded apertures, and the main electronics. The WXM
counters are sensitive to X-rays between 2 keV and 25 keV within a
field-of-view of about 1.5 sr, with a total detector area of about 350 cm.
The in-flight triggering and localization capability can produce a real-time
GRB location of several to 30 arcmin accuracy, with a limiting sensitivity of
erg cm. In this report, the details of the mechanical
structure, electronics, on-board software, ground and in-flight calibration,
and in-flight performance of the WXM are discussed.Comment: 28 pages, 24 figure
Recommended from our members
Correction of megavoltage cone-beam CT images of the pelvic region based on phantom measurements for dose calculation purposes.
Megavoltage cone-beam CT (MVCBCT) is an imaging technology that provides a 3D representation of the patient in treatment position. Because it is a form of x-ray tomography, MVCBCT images give information about the attenuation coefficients of the imaged tissues, and thus could be used for dose calculation. However, the cupping and missing data artifacts seen on MVCBCT images can cause inaccuracies in dose calculations. To eliminate these inaccuracies, a correction method specific to pelvis imaging and based on phantom measurements has been devised. Pelvis-shaped water phantoms of three different sizes were designed and imaged with MVCBCT. Three sets of correction factors were created from the artifacts observed in these MVCBCT images by dividing the measured CT number by the predefined CT number for water. Linear interpolation is performed between the sets of correction factors to take into account the varying size of different patients. To compensate for the missing anatomy due to the limited field of view of the MVCBCT system, the MVCBCT image is complemented with the kilovoltage CT (kVCT) image acquired for treatment planning.When the correction method is applied to an anthropomorphic pelvis phantom, the standard deviation between dose calculations performed with kVCT and MVCBCT images is 0.6%, with 98% of the dose points agreeing within +/- 3%.With uncorrected MVCBCT images this percentage falls to 75%. An example of dose calculation performed with a corrected clinicalMVCBCT image of a prostate cancer patient shows that changes in anatomy of normal tissues result in variation of the dose distribution received by these tissues.This correction method enablesMVCBCT images to be used for the verification of the daily dose distribution for patients treated in the pelvis region
The development of near field probing systems for EMC near field visualization and EMI source localization
The objectives of this research are to visualize the frequency dependent electromagnetic field distribution for electromagnetic compatibility (EMC) applications and the radiating source reconstruction on complex shaped electronic systems. This is achieved by combining near field probing with a system for automatically recording the probe position and orientation. Due to the complexity of the shape of the electronic systems of interest, and for utilizing the expertise of the user, the probe will be moved manually not robotically. Concurrently, the local near field will be recorded, associated with the location and displayed at near real time on the captured 3D geometry as a field strength map for EMC applications and, for source reconstruction, a reconstructed image showing the far field radiating sources. --Abstract, page iii
Gemini Planet Imager Observational Calibrations II: Detector Performance and Calibration
The Gemini Planet Imager is a newly commissioned facility instrument designed
to measure the near-infrared spectra of young extrasolar planets in the solar
neighborhood and obtain imaging polarimetry of circumstellar disks. GPI's
science instrument is an integral field spectrograph that utilizes a HAWAII-2RG
detector with a SIDECAR ASIC readout system. This paper describes the detector
characterization and calibrations performed by the GPI Data Reduction Pipeline
to compensate for effects including bad/hot/cold pixels, persistence,
non-linearity, vibration induced microphonics and correlated read noise.Comment: 11 pages, 6 figures. Proceedings of the SPIE, 9147-28
- …