743 research outputs found

    Stereoscopic visual saliency prediction based on stereo contrast and stereo focus

    Full text link
    © 2017, The Author(s). In this paper, we exploit two characteristics of stereoscopic vision: the pop-out effect and the comfort zone. We propose a visual saliency prediction model for stereoscopic images based on stereo contrast and stereo focus models. The stereo contrast model measures stereo saliency based on the color/depth contrast and the pop-out effect. The stereo focus model describes the degree of focus based on monocular focus and the comfort zone. After obtaining the values of the stereo contrast and stereo focus models in parallel, an enhancement based on clustering is performed on both values. We then apply a multi-scale fusion to form the respective maps of the two models. Last, we use a Bayesian integration scheme to integrate the two maps (the stereo contrast and stereo focus maps) into the stereo saliency map. Experimental results on two eye-tracking databases show that our proposed method outperforms the state-of-the-art saliency models

    Biosignalų požymių regos diskomfortui vertinti išskyrimas ir tyrimas

    Get PDF
    Comfortable stereoscopic perception continues to be an essential area of research. The growing interest in virtual reality content and increasing market for head-mounted displays (HMDs) still cause issues of balancing depth perception and comfortable viewing. Stereoscopic views are stimulating binocular cues – one type of several available human visual depth cues which becomes conflicting cues when stereoscopic displays are used. Depth perception by binocular cues is based on matching of image features from one retina with corresponding features from the second retina. It is known that our eyes can tolerate small amounts of retinal defocus, which is also known as Depth of Focus. When magnitudes are larger, a problem of visual discomfort arises. The research object of the doctoral dissertation is a visual discomfort level. This work aimed at the objective evaluation of visual discomfort, based on physiological signals. Different levels of disparity and the number of details in stereoscopic views in some cases make it difficult to find the focus point for comfortable depth perception quickly. During this investigation, a tendency for differences in single sensor-based electroencephalographic EEG signal activity at specific frequencies was found. Additionally, changes in eye tracker collected gaze signals were also found. A dataset of EEG and gaze signal records from 28 control subjects was collected and used for further evaluation. The dissertation consists of an introduction, three chapters and general conclusions. The first chapter reveals the fundamental knowledge ways of measuring visual discomfort based on objective and subjective methods. In the second chapter theoretical research results are presented. This research was aimed to investigate methods which use physiological signals to detect changes on the level of sense of presence. Results of the experimental research are presented in the third chapter. This research aimed to find differences in collected physiological signals when a level of visual discomfort changes. An experiment with 28 control subjects was conducted to collect these signals. The results of the thesis were published in six scientific publications – three in peer-reviewed scientific papers, three in conference proceedings. Additionally, the results of the research were presented in 8 conferences.Dissertatio

    GazeStereo3D: seamless disparity manipulations

    Get PDF
    Producing a high quality stereoscopic impression on current displays is a challenging task. The content has to be carefully prepared in order to maintain visual comfort, which typically affects the quality of depth reproduction. In this work, we show that this problem can be significantly alleviated when the eye fixation regions can be roughly estimated. We propose a new method for stereoscopic depth adjustment that utilizes eye tracking or other gaze prediction information. The key idea that distinguishes our approach from the previous work is to apply gradual depth adjustments at the eye fixation stage, so that they remain unnoticeable. To this end, we measure the limits imposed on the speed of disparity changes in various depth adjustment scenarios, and formulate a new model that can guide such seamless stereoscopic content processing. Based on this model, we propose a real-time controller that applies local manipulations to stereoscopic content to find the optimum between depth reproduction and visual comfort. We show that the controller is mostly immune to the limitations of low-cost eye tracking solutions. We also demonstrate benefits of our model in off-line applications, such as stereoscopic movie production, where skillful directors can reliably guide and predict viewers' attention or where attended image regions are identified during eye tracking sessions. We validate both our model and the controller in a series of user experiments. They show significant improvements in depth perception without sacrificing the visual quality when our techniques are applied

    Engineering data compendium. Human perception and performance. User's guide

    Get PDF
    The concept underlying the Engineering Data Compendium was the product of a research and development program (Integrated Perceptual Information for Designers project) aimed at facilitating the application of basic research findings in human performance to the design and military crew systems. The principal objective was to develop a workable strategy for: (1) identifying and distilling information of potential value to system design from the existing research literature, and (2) presenting this technical information in a way that would aid its accessibility, interpretability, and applicability by systems designers. The present four volumes of the Engineering Data Compendium represent the first implementation of this strategy. This is the first volume, the User's Guide, containing a description of the program and instructions for its use

    Comfort-driven disparity adjustment for stereoscopic video

    Get PDF
    Pixel disparity—the offset of corresponding pixels between left and right views—is a crucial parameter in stereoscopic three-dimensional (S3D) video, as it determines the depth perceived by the human visual system (HVS). Unsuitable pixel disparity distribution throughout an S3D video may lead to visual discomfort. We present a unified and extensible stereoscopic video disparity adjustment framework which improves the viewing experience for an S3D video by keeping the perceived 3D appearance as unchanged as possible while minimizing discomfort. We first analyse disparity and motion attributes of S3D video in general, then derive a wide-ranging visual discomfort metric from existing perceptual comfort models. An objective function based on this metric is used as the basis of a hierarchical optimisation method to find a disparity mapping function for each input video frame. Warping-based disparity manipulation is then applied to the input video to generate the output video, using the desired disparity mappings as constraints. Our comfort metric takes into account disparity range, motion, and stereoscopic window violation; the framework could easily be extended to use further visual comfort models. We demonstrate the power of our approach using both animated cartoons and real S3D videos

    Remote Visual Observation of Real Places Through Virtual Reality Headsets

    Get PDF
    Virtual Reality has always represented a fascinating yet powerful opportunity that has attracted studies and technology developments, especially since the latest release on the market of powerful high-resolution and wide field-of-view VR headsets. While the great potential of such VR systems is common and accepted knowledge, issues remain related to how to design systems and setups capable of fully exploiting the latest hardware advances. The aim of the proposed research is to study and understand how to increase the perceived level of realism and sense of presence when remotely observing real places through VR headset displays. Hence, to produce a set of guidelines that give directions to system designers about how to optimize the display-camera setup to enhance performance, focusing on remote visual observation of real places. The outcome of this investigation represents unique knowledge that is believed to be very beneficial for better VR headset designs towards improved remote observation systems. To achieve the proposed goal, this thesis presents a thorough investigation of existing literature and previous researches, which is carried out systematically to identify the most important factors ruling realism, depth perception, comfort, and sense of presence in VR headset observation. Once identified, these factors are further discussed and assessed through a series of experiments and usability studies, based on a predefined set of research questions. More specifically, the role of familiarity with the observed place, the role of the environment characteristics shown to the viewer, and the role of the display used for the remote observation of the virtual environment are further investigated. To gain more insights, two usability studies are proposed with the aim of defining guidelines and best practices. The main outcomes from the two studies demonstrate that test users can experience an enhanced realistic observation when natural features, higher resolution displays, natural illumination, and high image contrast are used in Mobile VR. In terms of comfort, simple scene layouts and relaxing environments are considered ideal to reduce visual fatigue and eye strain. Furthermore, sense of presence increases when observed environments induce strong emotions, and depth perception improves in VR when several monocular cues such as lights and shadows are combined with binocular depth cues. Based on these results, this investigation then presents a focused evaluation on the outcomes and introduces an innovative eye-adapted High Dynamic Range (HDR) approach, which the author believes to be of great improvement in the context of remote observation when combined with eye-tracked VR headsets. Within this purpose, a third user study is proposed to compare static HDR and eye-adapted HDR observation in VR, to assess that the latter can improve realism, depth perception, sense of presence, and in certain cases even comfort. Results from this last study confirmed the author expectations, proving that eye-adapted HDR and eye tracking should be used to achieve best visual performances for remote observation in modern VR systems

    Visual discomfort whilst viewing 3D stereoscopic stimuli

    Get PDF
    3D stereoscopic technology intensifies and heightens the viewer s experience by adding an extra dimension to the viewing of visual content. However, with expansion of this technology to the commercial market concerns have been expressed about the potential negative effects on the visual system, producing viewer discomfort. The visual stimulus provided by a 3D stereoscopic display differs from that of the real world, and so it is important to understand whether these differences may pose a health hazard. The aim of this thesis is to investigate the effect of 3D stereoscopic stimulation on visual discomfort. To that end, four experimental studies were conducted. In the first study two hypotheses were tested. The first hypothesis was that the viewing of 3D stereoscopic stimuli, which are located geometrically beyond the screen on which the images are displayed, would induce adaptation changes in the resting position of the eyes (exophoric heterophoria changes). The second hypothesis was that participants whose heterophoria changed as a consequence of adaptation during the viewing of the stereoscopic stimuli would experience less visual discomfort than those people whose heterophoria did not adapt. In the experiment an increase of visual discomfort change in the 3D condition in comparison with the 2D condition was found. Also, there were statistically significant changes in heterophoria under 3D conditions as compared with 2D conditions. However, there was appreciable variability in the magnitude of this adaptation among individuals, and no correlation between the amount of heterophoria change and visual discomfort change was observed. In the second experiment the two hypotheses tested were based on the vergence-accommodation mismatch theory, and the visual-vestibular mismatch theory. The vergence-accommodation mismatch theory predicts that a greater mismatch between the stimuli to accommodation and to vergence would produce greater symptoms in visual discomfort when viewing in 3D conditions than when viewing in 2D conditions. An increase of visual discomfort change in the 3D condition in comparison with the 2D condition was indeed found; however the magnitude of visual discomfort reported did not correlate with the mismatch present during the watching of 3D stereoscopic stimuli. The visual-vestibular mismatch theory predicts that viewing a stimulus stereoscopically will produce a greater sense of vection than viewing it in 2D. This will increase the conflict between the signals from the visual and vestibular systems, producing greater VIMS (Visually- Induced Motion Sickness) symptoms. Participants did indeed report an increase in motion sickness symptoms in the 3D condition. Furthermore, participants with closer seating positions reported more VIMS than participants sitting farther away whilst viewing 3D stimuli. This suggests that the amount of visual field stimulated during 3D presentation affects VIMS, and is an important factor in terms of viewing comfort. In the study more younger viewers (21 to 39 years old) than older viewers (40 years old and older) reported a greater change in visual discomfort during the 3D condition than the 2D condition. This suggests that the visual system s response to a stimulus, rather than the stimulus itself, is a reason for discomfort. No influence of gender on viewing comfort was found. In the next experiment participants fusion capability, as measured by their fusional reserves, was examined to determine whether this component has an impact on reported discomfort during the watching of movies in the 3D condition versus the 2D condition. It was hypothesised that participants with limited fusional range would experience more visual discomfort than participants with a wide fusion range. The hypothesis was confirmed but only in the case of convergent and not divergent eye movement. This observation illustrates that participants capability to convergence has a significant impact on visual comfort. The aim of the last experiment was to examine responses of the accommodation system to changes in 3D stimulus position and to determine whether discrepancies in these responses (i.e. accommodation overshoot, accommodation undershoot) could account for visual discomfort experienced during 3D stereoscopic viewing. It was found that accommodation discrepancy was larger for perceived forwards movement than for perceived backwards movement. The discrepancy was slightly higher in the group susceptible to visual discomfort than in the group not susceptible to visual discomfort, but this difference was not statistically significant. When considering the research findings as a whole it was apparent that not all participants experienced more discomfort whilst watching 3D stereoscopic stimuli than whilst watching 2D stimuli. More visual discomfort in the 3D condition than in the 2D condition was reported by 35% of the participants, whilst 24% of the participants reported more headaches and 17% of the participants reported more VIMS. The research indicates that multiple causative factors have an impact on reported symptoms. The analysis of the data suggests that discomfort experienced by people during 3D stereoscopic stimulation may reveal binocular vision problems. This observation suggests that 3D technology could be used as a screening method to diagnose un-treated binocular vision disorder. Additionally, this work shows that 3D stereoscopic technology can be easily adopted to binocular vision measurement. The conclusion of this thesis is that many people do not suffer adverse symptoms when viewing 3D stereoscopic displays, but that if adverse symptoms are present they can be caused either by the conflict in the stimulus, or by the heightened experience of self-motion which leads to Visually-Induced Motion Sickness (VIMS)
    corecore