849 research outputs found

    A review of the effectiveness of lower limb orthoses used in cerebral palsy

    Get PDF
    To produce this review, a systematic literature search was conducted for relevant articles published in the period between the date of the previous ISPO consensus conference report on cerebral palsy (1994) and April 2008. The search terms were 'cerebral and pals* (palsy, palsies), 'hemiplegia', 'diplegia', 'orthos*' (orthoses, orthosis) orthot* (orthotic, orthotics), brace or AFO

    How a Diverse Research Ecosystem Has Generated New Rehabilitation Technologies: Review of NIDILRR’s Rehabilitation Engineering Research Centers

    Get PDF
    Over 50 million United States citizens (1 in 6 people in the US) have a developmental, acquired, or degenerative disability. The average US citizen can expect to live 20% of his or her life with a disability. Rehabilitation technologies play a major role in improving the quality of life for people with a disability, yet widespread and highly challenging needs remain. Within the US, a major effort aimed at the creation and evaluation of rehabilitation technology has been the Rehabilitation Engineering Research Centers (RERCs) sponsored by the National Institute on Disability, Independent Living, and Rehabilitation Research. As envisioned at their conception by a panel of the National Academy of Science in 1970, these centers were intended to take a “total approach to rehabilitation”, combining medicine, engineering, and related science, to improve the quality of life of individuals with a disability. Here, we review the scope, achievements, and ongoing projects of an unbiased sample of 19 currently active or recently terminated RERCs. Specifically, for each center, we briefly explain the needs it targets, summarize key historical advances, identify emerging innovations, and consider future directions. Our assessment from this review is that the RERC program indeed involves a multidisciplinary approach, with 36 professional fields involved, although 70% of research and development staff are in engineering fields, 23% in clinical fields, and only 7% in basic science fields; significantly, 11% of the professional staff have a disability related to their research. We observe that the RERC program has substantially diversified the scope of its work since the 1970’s, addressing more types of disabilities using more technologies, and, in particular, often now focusing on information technologies. RERC work also now often views users as integrated into an interdependent society through technologies that both people with and without disabilities co-use (such as the internet, wireless communication, and architecture). In addition, RERC research has evolved to view users as able at improving outcomes through learning, exercise, and plasticity (rather than being static), which can be optimally timed. We provide examples of rehabilitation technology innovation produced by the RERCs that illustrate this increasingly diversifying scope and evolving perspective. We conclude by discussing growth opportunities and possible future directions of the RERC program

    International Conference on NeuroRehabilitation 2012

    Get PDF
    This volume 3, number 2 gathers a set of articles based on the most outstanding research on accessibility and disability issues that was presented in the International Conference on NeuroRehabilitation 2012 (ICNR).The articles’ research present in this number is centred on the analysis and/or rehabilitation of body impairment most due to brain injury and neurological disorders.JACCES thanks the collaboration of the ICNR members and the research authors and reviewers that have collaborated for making possible that issue

    GENTLE/A - Adaptive Robotic Assistance for Upper-Limb Rehabilitation

    Get PDF
    Advanced devices that can assist the therapists to offer rehabilitation are in high demand with the growing rehabilitation needs. The primary requirement from such rehabilitative devices is to reduce the therapist monitoring time. If the training device can autonomously adapt to the performance of the user, it can make the rehabilitation partly self-manageable. Therefore the main goal of our research is to investigate how to make a rehabilitation system more adaptable. The strategy we followed to augment the adaptability of the GENTLE/A robotic system was to (i) identify the parameters that inform about the contribution of the user/robot during a human-robot interaction session and (ii) use these parameters as performance indicators to adapt the system. Three main studies were conducted with healthy participants during the course of this PhD. The first study identified that the difference between the position coordinates recorded by the robot and the reference trajectory position coordinates indicated the leading/lagging status of the user with respect to the robot. Using the leadlag model we proposed two strategies to enhance the adaptability of the system. The first adaptability strategy tuned the performance time to suit the user’s requirements (second study). The second adaptability strategy tuned the task difficulty level based on the user’s leading or lagging status (third study). In summary the research undertaken during this PhD successfully enhanced the adaptability of the GENTLE/A system. The adaptability strategies evaluated were designed to suit various stages of recovery. Apart from potential use for remote assessment of patients, the work presented in this thesis is applicable in many areas of human-robot interaction research where a robot and human are involved in physical interaction

    Wearables for Movement Analysis in Healthcare

    Get PDF
    Quantitative movement analysis is widely used in clinical practice and research to investigate movement disorders objectively and in a complete way. Conventionally, body segment kinematic and kinetic parameters are measured in gait laboratories using marker-based optoelectronic systems, force plates, and electromyographic systems. Although movement analyses are considered accurate, the availability of specific laboratories, high costs, and dependency on trained users sometimes limit its use in clinical practice. A variety of compact wearable sensors are available today and have allowed researchers and clinicians to pursue applications in which individuals are monitored in their homes and in community settings within different fields of study, such movement analysis. Wearable sensors may thus contribute to the implementation of quantitative movement analyses even during out-patient use to reduce evaluation times and to provide objective, quantifiable data on the patients’ capabilities, unobtrusively and continuously, for clinical purposes

    Modulation of Corticospinal Excitability Using Cathodal Transcranial Direct Current Stimulation to Improve Walking in Individuals with Chronic Post Stroke Hemiparesis

    Full text link
    Background and Purpose: Individuals who have experienced a pyramidal cerebrovascular accident (pCVA) often exhibit impairments to volitional control of corresponding motor tasks. Promising effects in motor response, post-application of transcranial direct current stimulation (tDCS), have been reported in studies on individuals with the ability to achieve independent gait for 20 minutes. These studies mainly examined the effects of combined tDCS with locomotor training on lower extremity function among higher functioning individuals post-stroke. The purpose of this study was to determine the effect of tDCS among individuals post-stroke who may not have independent ambulatory capabilities, focusing on motor response and less demanding outcomes. The results of this study will extend knowledge on tDCS effects among lower functioning individuals post-CVA. Methods: Four individuals with chronic stroke (2.38 ± 0.63 years) randomly received either cathodal stimulation or a sham treatment to their non-lesioned hemisphere. Transcranial magnetic stimulation (TMS) was used in order identify the tibialis anterior hotspot in the motor cortex of their lesioned hemisphere such that we were able to assess and reassess the effects of tDCS at the same hotspot location. Fourteen days later, subjects attended a second session where they received the intervention that they did not receive in the first session (either sham or cathodal tDCS). Lower extremity (LE) function was evaluated by comparing pre and post intervention Timed Up and Go (TUG) scores, as well as Step Length, Stride Length, Stride Width, Stance Time, Swing Time, Gait Velocity, Ambulation Time, and Cadence. Motor response was evaluated by comparing pre and post intervention Motor Evoked Potential (MEP) values. Results: There was a statistically significant change in the MEP value measured before and after cathodal tDCS compared to sham (p = 0.037 \u3c 0.05). There was no statistically significant difference when comparing tDCS to sham interventions for: resting motor threshold maximum stimulator output (rMT MSO%), TUG, Step Length, Stride Length, Stride Width, Stance Time, Swing Time, Gait Velocity, Ambulation Time, and Cadence. Discussion: For those who are living post-stroke, the application of cathodal tDCS may provide a relative increase in cortical excitability of the ipsilesional hemisphere. Future tDCS research should incorporate functional interventions to see if they can promote lasting effects

    Advancing Medical Technology for Motor Impairment Rehabilitation: Tools, Protocols, and Devices

    Get PDF
    Excellent motor control skills are necessary to live a high-quality life. Activities such as walking, getting dressed, and feeding yourself may seem mundane, but injuries to the neuromuscular system can render these tasks difficult or even impossible to accomplish without assistance. Statistics indicate that well over 100 million people are affected by diseases or injuries, such as stroke, Parkinson’s Disease, Multiple Sclerosis, Cerebral Palsy, peripheral nerve injury, spinal cord injury, and amputation, that negatively impact their motor abilities. This wide array of injuries presents a challenge to the medical field as optimal treatment paradigms are often difficult to implement due to a lack of availability of appropriate assessment tools, the inability for people to access the appropriate medical centers for treatment, or altogether gaps in technology for treating the underlying impairments causing the disability. Addressing each of these challenges will improve the treatment of movement impairments, provide more customized and continuous treatment to a larger number of patients, and advance rehabilitative and assistive device technology. In my research, the key approach was to develop tools to assess and treat upper extremity movement impairment. In Chapter 2.1, I challenged a common biomechanical[GV1] modeling technique of the forearm. Comparing joint torque values through inverse dynamics simulation between two modeling platforms, I discovered that representing the forearm as a single cylindrical body was unable to capture the inertial parameters of a physiological forearm which is made up of two segments, the radius and ulna. I split the forearm segment into a proximal and distal segment, with the rationale being that the inertial parameters of the proximal segment could be tuned to those of the ulna and the inertial parameters of the distal segment could be tuned to those of the radius. Results showed a marked increase in joint torque calculation accuracy for those degrees of freedom that are affected by the inertial parameters of the radius and ulna. In Chapter 2.2, an inverse kinematic upper extremity model was developed for joint angle calculations from experimental motion capture data, with the rationale being that this would create an easy-to-use tool for clinicians and researchers to process their data. The results show accurate angle calculations when compared to algebraic solutions. Together, these chapters provide easy-to-use models and tools for processing movement assessment data. In Chapter 3.1, I developed a protocol to collect high-quality movement data in a virtual reality task that is used to assess hand function as part of a Box and Block Test. The goal of this chapter is to suggest a method to not only collect quality data in a research setting but can also be adapted for telehealth and at home movement assessment and rehabilitation. Results indicate that the data collected in this protocol are good and the virtual nature of this approach can make it a useful tool for continuous, data driven care in clinic or at home. In Chapter 3.2 I developed a high-density electromyography device for collecting motor unit action potentials of the arm. Traditional surface electromyography is limited by its ability to obtain signals from deep muscles and can also be time consuming to selectively place over appropriate muscles. With this high-density approach, muscle coverage is increased, placement time is decreased, and deep muscle activity can potentially be collected due to the high-density nature of the device[GV2] . Furthermore, the high-density electromyography device is built as a precursor to a high-density electromyography-electrical stimulation device for functional electrical stimulation. The customizable nature of the prototype in Chapter 3.2 allows for the implementation both recording and stimulating electrodes. Furthermore, signal results show that the electromyography data obtained from the device are of high quality and are correlated with gold standard surface electromyography sensors. One key factor in a device that can record and then stimulate based on the information from the recorded signals is an accurate movement intent decoder. High-quality movement decoders have been designed by closed-loop device controllers in the past, but they still struggle when the user interacts with objects of varying weight due to underlying alterations in muscle signals. In Chapter 4, I investigate this phenomenon by administering an experiment where participants perform a Box and Block Task with objects of 3 different weights, 0 kg, 0.02 kg, and 0.1 kg. Electromyography signals of the participants right arm were collected and co-contraction levels between antagonistic muscles were analyzed to uncover alterations in muscle forces and joint dynamics. Results indicated contraction differences between the conditions and also between movement stages (contraction levels before grabbing the block vs after touching the block) for each condition. This work builds a foundation for incorporating object weight estimates into closed-loop electromyography device movement decoders. Overall, we believe the chapters in this thesis provide a basis for increasing availability to movement assessment tools, increasing access to effective movement assessment and rehabilitation, and advance the medical device and technology field
    • 

    corecore