26 research outputs found

    Transtubular Resection of Spinal Intradural LĂ©sions : Techniques, Results, & Complications.

    Get PDF
    Le travail de thĂšse ici prĂ©sentĂ© a Ă©tĂ© publiĂ© sous forme d’un article scientifique ayant le titre « Image guided tailored access resection (IMTAR) of spinal intradural tumors. Technical report of 13 cases » L’article prĂ©sente les rĂ©sultats de la chirurgie per « accĂšs minime » (MAS) utilisĂ©e dans notre Ă©tablissement hospitalier avec une implĂ©mentation de la technique guidĂ©e par image que nous appelons « technique de navigation chirurgicale guidĂ©e par fusion d’image » (en anglais : Image Merge Tailored Access Resection ou IMTAR). IMTAR reprĂ©sente l’application d’une technique de fusion d’image dĂ©jĂ  existante pour la chirurgie crĂąnienne qui consiste Ă  fusionner les images de la rĂ©sonance magnĂ©tique prĂ©opĂ©ratoire avec les images de fluoroscopie 3D obtenues pendant la chirurgie pour naviguer Ă  la fois les structures osseuses et les tissus mous. La fusion d’image donne au chirurgien la possibilitĂ© de mieux planifier l’accĂšs chirurgical par la navigation virtuelle sur les images avant l’incision. Le chirurgien peut donc adapter l’abord chirurgical selon la localisation de la lĂ©sion et Ă©galement adapter la rĂ©section d’os en fonction de la fenĂȘtre d’exposition nĂ©cessaire pour la visualisation de la lĂ©sion tumorale. Le choix d’utiliser la technique IMTAR est pris en prĂ©opĂ©ratoire par le chirurgien en fonction de la disponibilitĂ© de cette technique dans un contexte de chirurgie Ă©lective. La technique est une implĂ©mentation d’une technique dĂ©jĂ  existante et bien validĂ©e par la littĂ©rature courante dont l’utilisation est faite au niveau crĂąnien, mais ici adaptĂ©e Ă  la chirurgie spinale. L’utilisation de la technique IMTAR a pour but de rĂ©duire le risque d’erreur de niveau de la localisation des lĂ©sions tumorales spinales, situation dĂ©crite en littĂ©rature. De plus, le choix de trajectoire d’accĂšs trans-musculaire selon la localisation de la lĂ©sion tumorale pourrait amĂ©liorer l’angle d’accĂšs aux lĂ©sions et minimiser le volume d’os enlevĂ© pendant l’abord chirurgical. Sur la sĂ©rie prĂ©liminaire de 13 patients dont les rĂ©sultats sont contenus dans l’article ici joint, la technique IMTAR a montrĂ© des rĂ©sultats d’exĂ©rĂšse tumorale superposables aux rĂ©sultats de la technique MAS non-naviguĂ©e. La procĂ©dure IMTAR semble ĂȘtre moins invasive en termes de rĂ©section osseuse et elle permet une meilleure localisation de la lĂ©sion. Le prĂ©sent travail de thĂšse s’est dĂ©roulĂ© dans le contexte de l’étude IMTAR, catĂ©gorie A (Protocole n. 172/15) approuvĂ© par le CER VD et en cours depuis 01.01.2017 au CHUV de Lausanne (investigateurs principales: Dr Rodolfo Maduri, Dr John Michael Duff). Les perspectives futures pour cette Ă©tude sont de dĂ©crire les rĂ©sultats chirurgicaux sur une « prospective cohort » de patients ayant bĂ©nĂ©ficiĂ© de la technique IMTAR et de la technique MAS non-naviguĂ©e jusqu’à la date de fin de l’étude. L’étude IMTAR a pour but d’évaluer les rĂ©sultats de l’utilisation de la technique IMTAR pour les tumeurs spinales par rapport Ă  la technique de chirurgie MAS classique en termes de minimisation de la morbiditĂ© associĂ©e Ă  l’abord chirurgical, de la rĂ©duction du risque d’une instabilitĂ© spinale iatrogĂšne et de l’optimisation de l’efficacitĂ© de la rĂ©section de la tumeur. -- - OBJECTIVE: Standard translaminar approaches for intradural extramedullary (IDEM) tumors require extensive soft tissue dissection and partial facet removal. Ventral lesions may necessitate wider bone resection with sub- sequent possible spinal instability. Any manipulation of an already compromised spinal cord may lead to neurological injury. We describe an image-guided minimal access technique for IDEM tumor resection. - METHODS: Retrospective chart review of 13 consecutive patients after institutional ethics committee approval. We superimpose preoperative magnetic resonance imaging data with intraoperative 3-dimensional fluoroscopic im- ages, allowing to simultaneously visualize osseous anat- omy and the soft tissue lesion using appropriate windowing. We then plan optimal angle of trajectory to the tumor, which defines the skin incision and the trans- muscular trajectory. A tubular retractor is placed to span the tumor. Microsurgical tumor resection is then carried out using this angle of approach. - RESULTS: Thirteen patients (mean age. 57 years; male-to- female ratio, 10:3) were operated on during 28 months. Gross total resection was achieved in all patients. Neuro- logical improvement occurred in 12 of the 13 patients. There was no neurological deficit outside of the expected sensory loss due to intentional nerve root sacrifice. No mechanical pain nor tumor recurrence were noted during the follow-up (mean, 16 months; range, 2e30 months). - CONCLUSIONS: Image merge tailored access resection appears to be at least equivalent in terms of tumor resec- tion, blood loss, and complications to other tubular tech- niques. It may reduce risks of neurological deficit and spine instability. Image merge tailored access resection is a novel application of merging intraoperative fluoroscopic images with preoperative magnetic resonance images for tailored IDEM resection

    Biopsies prostatiques ciblées guidées par IRM dans le diagnostic du cancer de prostate (revue de la littérature et expérience clinique initiale avec l'UrostationŸ)

    Get PDF
    Deux axes principaux se dégagent de notre étude de la littérature : la réalisation de biopsies avec guidage direct dans l IRM, et la fusion d image échographie-IRM. Les premiÚres offrent une grande précision, mais restent limitées par l accessibilité, le coût et la durée de ces procédures. La fusion d images est un compromis prometteur associant la précision et la spécificité de l IRM multiparamétrique, et la facilité d accÚs et d utilisation de l échographie endorectale. Plusieurs systÚmes ont ainsi été développés, dont l UrostationŸ, offrant la possibilité de réaliser des biopsies ciblées à l aide d une fusion d images échographiques 3D et IRM. Nous avons inclus de maniÚre prospective entre novembre 2011 et août 2012, 30 patients présentant une indication de biopsies prostatiques ayant réalisé une IRM multiparamétrique au CHU de Grenoble. Un protocole de 12 biopsies randomisées a été réalisé, ainsi que 2 biopsies ciblées en cas de zone suspecte. Un cancer de prostate a été diagnostiqué dans 14 cas (47%), dont 3 cancers sans anomalie IRM. Onze cancers ont été considérés cliniquement significatifs. Dans notre étude, un protocole de 2 biopsies ciblées réalisé en cas d IRM anormale avec PI-RADS score >8 aurait négligé un cancer significatif, mais évité 15 procédures inutiles et 2 cas de sur-diagnostic de cancers non significatifs, avec une sensibilité de 91% pour la détection d un cancer de prostate significatif. Des études de plus grande ampleur seront nécessaires pour définir la place de l IRM avant biopsie, des biopsies ciblées, et enfin de la fusion écho-IRM, à l heure de la robotisation, de l émergence des traitements focaux et de la réflexion sur le sur-traitement.The systematic review of the literature showed that research is focused on two main areas: direct biopsy guidance inside the MRI, and MRI-ultrasound fusion. The first offer a high precision, but are still limited by the accessibility, cost and duration of these procedures. Image fusion is a promising compromise, associating the precision and specificity of multiparametric MRI, and the accessibility and usability of transrectal ultrasound. Several systems have therefore been developped, including the UrostationŸ, to allow biopsy guidance based on 3D ultrasound and MRI fusion. Between November, 2011 and August, 2012, we prospectively included 30 patients presenting with an indication for prostate biopsies, who first had a multiparametric MRI in the Grenoble University Hospital. A 12-core randomised biopsy protocol was performed, as well as 2 targeted biopsies in case of suspicious lesion. Prostate cancer was detected in 14 cases (47%), including 3 cancers with MRI considered normal. Eleven cancers were considered clinically significant. In our study, a 2-core targeted biopsy protocol performed only in case of abnormal MRI with a PI-RADS score >8 would have missed one significant cancer, but avoided 15 unnecessary procedures and 2 cases of over-diagnosis of insignificant cancers, with a 91% sensitivity for the detection of significant prostate cancer. Further, larger studies are needed to define the place of MRI prior to biopsy, of targeted biopsies, and finally of MRI-ultrasound fusion, in the context of the developpement of robotics, emergence of focal therapies, and reflection on over-treatment.GRENOBLE1-BU Médecine pharm. (385162101) / SudocSudocFranceF

    La chaĂźne image SPOT5 THR : un exemple d'optimisation globale

    Get PDF
    - Issu de la filiÚre SPOT, le satellite de télédétection optique SPOT5 s'en démarque par un mode d'échantillonnage quinconce adapté à la Fonction de Transfert de Modulation (FTM) de l'instrument et généré par un détecteur spécifique comportant deux barrettes CCD décalées dans le plan focal. En raison des faibles valeurs de la FTM pour les hautes fréquences spatiales, les images produites par un tel systÚme sont floues et nécessitent un traitement sol complexe d'interpolation quinconce, de déconvolution linéaire et de débruitage par seuillage de coefficients de paquets d'ondelettes

    ModÚles de fusion et diffusion par équations aux dérivées partielles (application à la sismique azimutale)

    Get PDF
    Ce mémoire porte sur le développement de nouvelles méthodes de fusion d images à partir d un formalisme à base d Equations aux Dérivées Partielles (EDP). Les deux premiers chapitres bibliographiques portent sur les 2 domaines au centre de notre problématique : la fusion et les EDP. Le Chapitre 3 est consacré à la présentation progressive de notre modÚle EDP de fusion constitué par un terme de fusion (diffusion inverse isotrope) et un terme de régularisation. De plus, un des attraits de l approche EDP est de pouvoir traiter avec le formalisme des données bruitées. L association d un terme de diffusion dépendant du type de données à traiter est donc abordée. Le chapitre 4 est consacré à l application des modÚles de fusion-diffusion aux données sismiques. Pour répondre aux besoins de filtrage de ces données sismiques, nous proposons deux méthodes originales de diffusion 3D. Nous présenterons dans ce mémoire l approche de fusion 3D intégrant une de ces méthodes nommée SFPD (Seismic Fault Preserving Diffusion).This thesis focuses on developing new methods for image fusion based on Partial Differential Equations (PDE). The starting point of the proposed fusion approach is the enhancement process contained in most classical diffusion models. The aim of enhancing contours is similar to one of the purpose of the fusion: the relevant information (equivalent to the contours) must be found in the output image. In general, the contour enhancement uses an inverse diffusion equation. In our model of fusion, the evolution of each input image is led by such equation. This single equation must necessarily be accompanied by a global information detector useful to select the signal to be injected. In addition, an inverse diffusion equation, like any Gaussian deconvolution, raises problems of stability and regularization of the solution. To resolve these problems, a regularization term is integrated into the model. The general model of fusion is finally similar to an evolving cooperative system, where the information contained in each image starts moving towards relevant information, leading to a convergent process. The essential interest of PDE approach is to deal with noisy data by combining in a natural way two processes: fusion and diffusion. The fusion-diffusion proposed model is easy to adapt to different types of data by tuning the PDE. In order to adapt the fusion-diffusion model to a specific application, I propose 2 diffusion models: Seismic fault preserving diffusion and 3D directional diffusion . The aim is to denoise 3D seismic data. These models are integrated into the fusion-diffusion approach. One of them is successfully transferred to the industrial partner: french oil company Total. The efficiency of our models (fusion and fusion-diffusion) is proven through an experimental plan in both noisy and noisy-free data.BORDEAUX1-Bib.electronique (335229901) / SudocSudocFranceF

    Etude de la variabilité inter- et intra-opérateur du volume de l'oreillette droite par l'IRM: travail de Bachelor

    Get PDF
    Nous avons rĂ©alisĂ© un protocole de segmentation pour l’analyse de l’oreillette droite grĂące au logiciel OsiriX dans le but de mesurer la variabilitĂ© inter- et intra-opĂ©rateur. Nous voulions vĂ©rifier si le TRM avait des rĂ©sultats comparables Ă  ceux d’un expert, le Professeur VallĂ©e. Nous avons chacun effectuĂ© un certain nombre de segmentations pour calculer le volume de l’atrium droit. D’un point de vue mĂ©dical, la mesure du volume de l’oreillette droite permet d’effectuer certains liens avec des pathologies

    Conception d'algorithmes innovants de traitement d'images de la rétine chez l'homme

    Get PDF
    Our objective was to analyze the importance of spatial and temporal variability of the reflectance of cones in counting for adaptive optics high resolution imaging, and propose ways to overcome these difficulties.The first part of the work focuses on the study of the temporal variability of cones. We confirmed the presence of a scintillation phenomenon at a frequency at least equal to that of our acquisition system. We have proposed an image analysis process including restoration by deconvolution, rigid registration, and image fusion for cone mapping. To validate this approach, we conducted a validation test for two deconvolution methods. We have shown that in the case of healthy subjects, the image fusion procedure to bring the measurement of cone density and histological references. The angular variation of cone reflectance is called optical Stiles-Crawford effect. We have identified a new clinical manifestation of this phenomenon, through a study on the analysis of adaptive optics images periphery). We have shown, through the alternation of the positive / negative mosaics, that the reflectance of the cones may become lower than that of rods. Comparison with the data of the optical coherence tomography showed a strong correlation of the switching with the outer segment layer. We then proposed a procedure of integration of spatial variability for cone mapping. This procedure was evaluated in healthy and diseased subjects and showed a significant gain (in terms of cone enumeration) in pathological cases.Notre objectif a été d'analyser l'influence de la variabilité spatio-temporelle de la réflectance des cÎnes sur le comptage des cÎnes par imagerie à haute résolution par optique adaptative plein champ, et de proposer des méthodes pour pallier ces difficultés. La premiÚre partie des travaux porte sur l'étude de la variabilité temporelle des cÎnes. Nous avons confirmé la présence d'un phénomÚne de scintillement des cÎnes à une fréquence au moins égale à celle de notre systÚme d'acquisition. Nous avons proposé une procédure d'analyse d'images incluant restauration par déconvolution myope, recalage rigide, fusion d'images pour la construction de cartographies de cÎnes. Nous avons montré que dans le cas des sujets sains, la procédure de fusion d'image permet de rapprocher la mesure de la densité des cÎnes des références histologiques. La directionalité de la réflectance des cÎnes est appelée effet Stiles-Crawford optique. Nous en avons identifié une nouvelle manifestation clinique, à travers une étude portant sur l'analyse d'images d'optique adaptative en périphérie de la rétine. Nous avons montré, à travers l'alternance des mosaïques positive/négative, que la réflectance des cÎnes peut devenir inférieure à celle des bùtonnets. La comparaison avec les données de la tomographie de cohérence optique a montré une forte corrélation de cette commutation avec la couche des segments externes des cÎnes. Nous avons proposé une procédure d'intégration de la variabilité spatiale pour la construction des cartographies. Cette procédure a été évaluée sur des sujets sains et pathologiques et a montré un gain significatif (en termes de dénombrement des cÎnes) chez les cas pathologiques

    Apport de l'assistance par ordinateur lors de la pose d'endoprothĂšse aortique

    Get PDF
    The development of endovascular aortic procedures is growing. These mini-invasive techniques allow a reduction of surgical trauma, usually important in conventional open surgery. The technical limitations of endovascular repair are pushed to special aortic localizations which were in the past decade indication for open repair. Success and efficiency of such procedures are based on the development and the implementation of decision-making tools. This work aims to improve endovascular procedures thanks to a better utilization of pre and intraoperative imaging. This approach is in the line with the framework of computer-assisted surgery whose concepts are applied to vascular surgery. The optimization of endograft deployment is considered in three steps. The first part is dedicated to preoperative imaging analysis and shows the limits of the current sizing tools. The accuracy of a new measurement criterion is assessed (outer curvature length). The second part deals with intraoperative imaging and shows the contribution of augmented reality in endovascular aortic repair. In the last part, image guided surgery on soft tissues is addressed, especially the arterial deformations occurring during endovascular procedures which disprove rigid registration in fusion imaging. The use of finite element simulation to deal with this issue is presented. We report an original approach based on a predictive model of deformations using finite element simulation with geometrical and anatomo-mechanical patient specific parameters extracted from the preoperative CT-scan.Les techniques endovasculaires, particuliĂšrement pour l’aorte, sont en plein essor en chirurgie vasculaire. Ces techniques mini-invasives permettent de diminuer l’agression chirurgicale habituellement importante lors de la chirurgie conventionnelle. Les limites techniques sont repoussĂ©es Ă  certaines localisations de l’aorte qui Ă©taient il y a encore peu de temps inaccessibles aux endoprothĂšses. Le succĂšs et l’efficience de ces interventions reposent en partie sur l'Ă©laboration et la mise en Ɠuvre de nouveaux outils d'aide Ă  la dĂ©cision. Ce travail entend contribuer Ă  l’amĂ©lioration des procĂ©dures interventionnelles aortiques grĂące Ă  une meilleure exploitation de l’imagerie prĂ© et peropĂ©ratoire. Cette dĂ©marche s’inscrit dans le cadre plus gĂ©nĂ©ral des Gestes MĂ©dico-Chirurgicaux AssistĂ©s par Ordinateur, dont les concepts sont revisitĂ©s pour les transposer au domaine de la chirurgie endovasculaire. Trois axes sont dĂ©veloppĂ©s afin de sĂ©curiser et optimiser la pose d'endoprothĂšse. Le premier est focalisĂ© sur l’analyse prĂ©opĂ©ratoire du scanner (sizing) et montre les limites des outils de mesure actuels et Ă©value la prĂ©cision d’un nouveau critĂšre de mesure des longueurs de l’aorte (courbure externe). Le deuxiĂšme axe se positionne sur le versant peropĂ©ratoire et montre la contribution de la rĂ©alitĂ© augmentĂ©e dans la pose d’une endoprothĂšse aortique. Le troisiĂšme axe s’intĂ©resse au problĂšme plus gĂ©nĂ©ral des interventions sur les tissus mous et particuliĂšrement aux dĂ©formations artĂ©rielles qui surviennent au cours des procĂ©dures interventionnelles qui mettent en dĂ©faut le recalage rigide lors de la fusion d’images. Nous prĂ©sentons une approche originale basĂ©e sur un modĂšle numĂ©rique de prĂ©diction des dĂ©formations qui utilise la simulation par Ă©lĂ©ments finis en y intĂ©grant des paramĂštres gĂ©omĂ©triques et anatomo-mĂ©caniques spĂ©cifique-patient extraits du scanner prĂ©opĂ©ratoire

    Fusion de données provenant de différents capteurs satellitaires pour le suivi de la qualité de l'eau en zones cÎtiÚres. Application au littoral de la région PACA

    Get PDF
    Monitoring coastal areas requires both a good spatial resolution, good spectral resolution associated with agood signal to noise ratio and finally a good temporal resolution to visualize rapid changes in water color.Available now, and even those planed soon, sensors do not provide both a good spatial, spectral ANDtemporal resolution. In this study, we are interested in the image fusion of two future sensors which are bothpart of the Copernicus program of the European Space Agency: MSI on Sentinel-2 and OLCI on Sentinel-3.Such as MSI and OLCI do not provide image yet, it was necessary to simulate them. We then used thehyperspectral imager HICO and we then proposed three methods: an adaptation of the method ARSIS fusionof multispectral images (ARSIS), a fusion method based on the non-negative factorization tensors (Tensor)and a fusion method based on the inversion de matrices (Inversion).These three methods were first evaluated using statistical parameters between images obtained by fusionand the "perfect" image as well as the estimation results of biophysical parameters obtained by minimizingthe radiative transfer model in water.Le suivi des zones cĂŽtiĂšres nĂ©cessite Ă  la fois une bonne rĂ©solution spatiale, une bonne rĂ©solution spectraleassociĂ©e Ă  un bon rapport signal sur bruit et enfin une bonne rĂ©solution temporelle pour visualiser deschangements rapides de couleur de l’eau.Les capteurs disponibles actuellement, et mĂȘme ceux prĂ©vus prochainement, n’apportent pas Ă  la fois unebonne rĂ©solution spatiale, spectrale ET temporelle. Dans cette Ă©tude, nous nous intĂ©ressons Ă  la fusion de 2futurs capteurs qui s’inscrivent tous deux dans le programme Copernicus de l’agence spatiale europĂ©enne:MSI sur Sentinel-2 et OLCI sur Sentinel-3.Comme les capteurs MSI et OLCI ne fournissent pas encore d’images, il a fallu les simuler. Pour cela nousavons eu recours aux images hyperspectrales du capteur HICO. Nous avons alors proposĂ© 3 mĂ©thodes : uneadaptation de la mĂ©thode ARSIS Ă  la fusion d’images multispectrales (ARSIS), une mĂ©thode de fusion basĂ©esur la factorisation de tenseurs non-nĂ©gatifs (Tenseur) et une mĂ©thode de fusion basĂ©e sur l’inversion dematrices (Inversion)Ces 3 mĂ©thodes ont tout d’abord Ă©tĂ© Ă©valuĂ©es Ă  l’aide de paramĂštres statistiques entre les images obtenuespar fusion et l’image « parfaite » ainsi que sur les rĂ©sultats d’estimation de paramĂštres biophysiques obtenuspar minimisation du modĂšle de transfert radiatif dans l’eau

    Analyse radiomique du cancer de la prostate pour la prédiction du pronostic des patients avec un grand risque de récidive

    Get PDF
    Les options thĂ©rapeutiques d'intention curative ont une faible probabilitĂ© de succĂšs chez les patients atteints d'un cancer de la prostate avec mĂ©tastases ganglionnaires. Ainsi, l'obtention d'une mĂ©thode de prĂ©diction de la prĂ©sence ou l'apparition de mĂ©tastases ganglionnaires est souhaitable. Ce document prĂ©sente le dĂ©veloppement d'un modĂšle de prĂ©diction de la prĂ©sence de mĂ©tastases ganglionnaires Ă  la prostatectomie radicale. Le modĂšle utilise les marqueurs radiomiques extraits de l'examen FDG-TEP/CT fait en prĂ©opĂ©ratoire. Ces marqueurs issus de la radiomique - dĂ©finie comme le processus d'extraction quantitative de donnĂ©es exploitables de haute dimension Ă  partir d'images mĂ©dicales - permettent de quantifier des caractĂ©ristiques invisibles Ă  l'Ɠil tels que les paramĂštres de texture et d'intensitĂ©. Dans un premier volet, afin de limiter les erreurs de recalage entre la TEP et le CT, une Ă©valuation de l'extraction des marqueurs radiomiques a Ă©tĂ© effectuĂ©e en comparant la valeur maximale d'absorption standardisĂ©e (SUVₘₐₓ) sur l'imagerie TEP. Une mĂ©thode de segmentation semi-automatique de la vessie en TEP a Ă©tĂ© dĂ©veloppĂ©e de maniĂšre Ă  soustraire la vessie de la segmentation de la prostate, ce qui permet une extraction plus juste des marqueurs radiomiques. Dans un second volet, une mĂ©thode de sĂ©lection des marqueurs radiomiques a Ă©tĂ© dĂ©veloppĂ©e afin de rĂ©duire les marqueurs redondants et de sĂ©lectionner les plus importants, ce qui a permis de sĂ©lectionner 17 marqueurs TEP. Lorsque combinĂ©s avec l'intelligence artificielle, les marqueurs radiomiques peuvent ĂȘtre utilisĂ©s pour la prĂ©diction de diffĂ©rents paramĂštres cliniques. Un modĂšle de prĂ©diction utilisant un classificateur par forĂȘts alĂ©atoires a permis d'obtenir des rĂ©sultats dĂ©montrant le potentiel de l'algorithme et des marqueurs radiomiques en FDG-TEP/CT. Une fois couplĂ© aux donnĂ©es cliniques, l'algorithme permet une meilleure prĂ©diction. Une AUC de (79 ± 9) % est obtenue lors de la combinaison du modĂšle de prĂ©diction avec le stade clinique de la tumeur.Therapeutic options with curative intent have a low probability of success in patients with prostate cancer with lymph node metastases. Therefore, a method for predicting the presence or development of lymph node metastases is desirable. This document presents the development of a model for predicting the presence of lymph node metastases at radical prostatectomy. The model uses radiomic markers extracted from the preoperative FDG-PET/CT examination. These radiomic markers - defined as the process of quantitatively extracting high-dimensional usable data from medical images - allow the quantification of features invisible to the eye such as texture and intensity parameters. In the first part, to limit the misalignment errors between PET and CT, an evaluation of the extraction of radiomic markers was carried out by comparing the standardized maximum absorption value (SUVₘₐₓ) on PET imaging. A semi-automatic PET bladder segmentation method was developed to subtract the bladder from the prostate segmentation, allowing a more accurate extraction of radiomic markers. In the second phase, a method for selecting radiomic markers was developed to reduce redundant markers and to select the most important ones, resulting in the selection of 17 PET markers. When combined with artificial intelligence, radiomic markers can be used for the prediction of various clinical parameters. A prediction model using a random forest classifier provided results demonstrating the potential of the algorithm and radiomic markers in FDG-PET/CT. Once coupled with clinical data, the algorithm allows a better prediction. AUC of (79 ± 9) % is obtained when combining the prediction model with the clinical stage of tumor
    corecore