103 research outputs found

    Rank-based camera spectral sensitivity estimation

    Get PDF
    In order to accurately predict a digital camera response to spectral stimuli, the spectral sensitivity functions of its sensor need to be known. These functions can be determined by direct measurement in the lab—a difficult and lengthy procedure—or through simple statistical inference. Statistical inference methods are based on the observation that when a camera responds linearly to spectral stimuli, the device spectral sensitivities are linearly related to the camera rgb response values, and so can be found through regression. However, for rendered images, such as the JPEG images taken by a mobile phone, this assumption of linearity is violated. Even small departures from linearity can negatively impact the accuracy of the recovered spectral sensitivities, when a regression method is used. In our work, we develop a novel camera spectral sensitivity estimation technique that can recover the linear device spectral sensitivities from linear images and the effective linear sensitivities from rendered images. According to our method, the rank order of a pair of responses imposes a constraint on the shape of the underlying spectral sensitivity curve (of the sensor). Technically, each rank-pair splits the space where the underlying sensor might lie in two parts (a feasible region and an infeasible region). By intersecting the feasible regions from all the ranked-pairs, we can find a feasible region of sensor space. Experiments demonstrate that using rank orders delivers equal estimation to the prior art. However, the Rank-based method delivers a step-change in estimation performance when the data is not linear and, for the first time, allows for the estimation of the effective sensitivities of devices that may not even have “raw mode.” Experiments validate our method

    Real Time Structured Light and Applications

    Get PDF

    Multiplexed Illumination for Scene Recovery in the Presence of Global Illumination

    Get PDF
    Global illumination effects such as inter-reflections and subsurface scattering result in systematic, and often significant errors in scene recovery using active illumination. Recently, it was shown that the direct and global components could be separated efficiently for a scene illuminated with a single light source. In this paper, we study the problem of direct-global separation for multiple light sources. We derive a theoretical lower bound for the number of required images, and propose a multiplexed illumination scheme which achieves this lower bound. We analyze the signal-to-noise ratio (SNR) characteristics of the proposed illumination multiplexing method in the context of direct-global separation. We apply our method to several scene recovery techniques requiring multiple light sources, including shape from shading, structured light 3D scanning, photometric stereo, and reflectance estimation. Both simulation and experimental results show that the proposed method can accurately recover scene information with fewer images compared to sequentially separating direct-global components for each light source

    Calibration and Analysis of a Multimodal Micro-CT and Structured Light Imaging System for the Evaluation of Excised Breast Tissue.

    Get PDF
    A multimodal micro-computed tomography (CT) and multi-spectral structured light imaging (SLI) system is introduced and systematically analyzed to test its feasibility to aid in margin delineation during breast conserving surgery (BCS). Phantom analysis of the micro-CT yielded a signal-to-noise ratio of 34, a contrast of 1.64, and a minimum detectable resolution of 240 ?m for a 1.2?min scan. The SLI system, spanning wavelengths 490?nm to 800?nm and spatial frequencies up to 1.37 , was evaluated with aqueous tissue simulating phantoms having variations in particle size distribution, scatter density, and blood volume fraction. The reduced scattering coefficient, and phase function parameter, ?, were accurately recovered over all wavelengths independent of blood volume fractions from 0% to 4%, assuming a flat sample geometry perpendicular to the imaging plane. The resolution of the optical system was tested with a step phantom, from which the modulation transfer function was calculated yielding a maximum resolution of 3.78 cycles per mm. The three dimensional spatial co-registration between the CT and optical imaging space was tested and shown to be accurate within 0.7?mm. A freshly resected breast specimen, with lobular carcinoma, fibrocystic disease, and adipose, was imaged with the system. The micro-CT provided visualization of the tumor mass and its spiculations, and SLI yielded superficial quantification of light scattering parameters for the malignant and benign tissue types. These results appear to be the first demonstration of SLI combined with standard medical tomography for imaging excised tumor specimens. While further investigations are needed to determine and test the spectral, spatial, and CT features required to classify tissue, this study demonstrates the ability of multimodal CT/SLI to quantify, visualize, and spatially navigate breast tumor specimens, which could potentially aid in the assessment of tumor margin status during BCS

    Dual-mode optical microscope based on single-pixel imaging

    Get PDF
    We demonstrate an inverted microscope that can image specimens in both reflection and transmission modes simultaneously with a single light source. The microscope utilizes a digital micromirror device (DMD) for patterned illumination altogether with two single-pixel photosensors for efficient light detection. The system, a scan-less device with no moving parts, works by sequential projection of a set of binary intensity patterns onto the sample that are codified onto a modified commercial DMD. Data to be displayed are geometrically transformed before written into a memory cell to cancel optical artifacts coming from the diamond-like shaped structure of the micromirror array. The 24-bit color depth of the display is fully exploited to increase the frame rate by a factor of 24, which makes the technique practicable for real samples. Our commercial DMD-based LED-illumination is cost effective and can be easily coupled as an add-on module for already existing inverted microscopes. The reflection and transmission information provided by our dual microscope complement each other and can be useful for imaging non-uniform samples and to prevent self-shadowing effects.This work was supported by MINECO through projects FIS2013-40666-P, the Generalitat Valenciana PROMETEO/2012/021, ISIC/2012/013, and by the Universitat Jaume I P1-1B2012-55. A.D. RodrĂ­guez acknowledges grant PREDOC/2012/41 from Universitat Jaume I. Thanks also to Dr. Tatiana Pina and Dr. Josep Jaques from Universitat Jaume I for providing us the biological samples
    • 