51 research outputs found

    Time domain analysis of switching transient fields in high voltage substations

    Get PDF
    Switching operations of circuit breakers and disconnect switches generate transient currents propagating along the substation busbars. At the moment of switching, the busbars temporarily acts as antennae radiating transient electromagnetic fields within the substations. The radiated fields may interfere and disrupt normal operations of electronic equipment used within the substation for measurement, control and communication purposes. Hence there is the need to fully characterise the substation electromagnetic environment as early as the design stage of substation planning and operation to ensure safe operations of the electronic equipment. This paper deals with the computation of transient electromagnetic fields due to switching within a high voltage air-insulated substation (AIS) using the finite difference time domain (FDTD) metho

    A bibliographic analysis of transformer literature 1990-2000

    Get PDF
    This paper presents an analysis of the bibliography on transformers covering the period from 1990 to 2000. It contains all the transformer subjects: a) Transformer design, b) Transformer protection, c) Transformer connections, d) Transformer diagnostics, e) Transformer failures, f) Transient analysis of transformers (overvoltages, overcurrents), g) Modeling and analysis of transformer using FEM (thermal modeling, losses modeling, insulation modeling, windings modeling). Several international journals were investigated including the following: Advances in Electrical and Computer Engineering, Canadian Journal of Electrical and Computer Engineering, COMPEL (The International Journal for Computation and Mathematics in Electrical and Electronic Engineering), Electrical Engineering, Electric Power Components and Systems, Electric Power Systems Research, European Transactions on Electrical Power, IEEE Transactions on Magnetics, IEEE Transactions on Power Delivery, International Journal of Electrical Power and Energy Systems, and IET Generation Transmission & Distribution. Due to the high number of publication in journals, we are not considering publications of conferences and symposia. A total of 700 publications are analyzed in this paper. The research presented in this paper is important because it contains and analyzes the best research papers on transformers coming from many countries all over the world and published in top rated scientific electrical engineering journals

    Reliability analysis of power transformers : case : Eskom Distribution Eastern Region, 1MVA to 80MVA power transformers.

    Get PDF
    Thesis (M.Sc.)-University of KwaZulu-Natal, 2007.This dissertation analyses the reliability of power transformers and its impact of failure on system performance. Eskom Distribution, Eastern Region is used as a practical case study, which has an installed transformer base of 6066MVA comprising of 428 transformers ranging from 1 MVA to 8OMVA with voltage levels of 6.6kV to I 32kV. The literature review illustrates the theory and principles of transformers, evolution and changes in design criteria, the function of cellulose and insulating oil, failure modes. operations and maintenance practices and factors affecting the distribution systems performance. This study included a conditional assessment and an oil analysis review of transformers at Eskom. A method to trend multiple oil samples was developed and illustrated. The research further investigates the reliability of series and parallel systems using actual component reliability values. A study was conducted to establish the degree of network firmness. Transformer failure data was analysed and were shown to be characteristic of a bathtub curve. Defects from on site inspections were analysed and identified oil leaks as a maintenance focus area. The Distribution Supply Loss Index was determined to be the major impact Key Performance Index due to transformer failures. Transformer failures using statistical methods, showed HV/LV winding to be the main component to fail. The cost of a transformer failure to Eskom and the customer was determined. International Benchmarking was investigated to establish the criteria for network reliability indices and to compare the network infrastructure and performance of international utilities and Eskom. The later part of the study involved the analysis of a risk ranking methodology to establish a risk ranking matrix. The transformers were ranked according to the matrix, identifying the high risk focus areas. Projects were raised within Eskom to replace the identified high risk transformers. This study has concluded that the reliability of transformers is impacted by the changes in transformer design, increased maintenance defects and inadequate transformer protection at substations. The reduced oil volume per kVA, increased hot spot and ambient temperature, and compact tank designs have resulted in the cellulose being overheated and fault gases being produced during normal operating conditions. The increase in load demand from the existing transformer fleet and a reduction in capital expenditure to maintain and build additional substations have also contributed to accelerated aging, since the transformers are forced to operate at 100 percent loading. There is an increase in transformer maintenance defects due to in sufficient operational staff, high staff turnover, reduced skills transfer. and insufficient network contingencies to allow for planned outages to clear the defects identified. The failure analysis showed that the main component to fail is HV/LV windings. The winding failures were traced to there being no or inadequate transformer protection at -20% of substations

    Life assessment and life extension of high voltage equipment in transmission substations.

    Get PDF
    Thesis (M.Sc.)-University of KwaZulu-Natal, Durban, 2004.In order to sustain transmission grid availability and reliability it is imperative that the condition of vital and costly high voltage equipment is ascertained on a continuous or regular basis. It is necessary to establish the effective diagnostic tools or surveillance devices that can be used to assess equipment condition. Emphasis has been placed on refining well-established and more novel but developing condition assessment techniques. It is important to note that condition assessment of equipment also allows the opportunity to predict failure. Based on a complete and systematic assessment, the failure of defective equipment may be evident or predicted in time, thus preventing a forced outage and loss of valuable 'system minutes'. It has also become necessary to extend the life of existing equipment since most of them are reaching the end of their useful life. Replacement strategies have proven to be ineffective due to financial and resource constraints experienced by utilities. Life extension is the work required to keep equipment operating economically beyond its anticipated life, with optimum availability, efficiency and safety. One of its principal components is condition assessment, with the possibility of predicting remnant life. As a result, refurbishment projects are then raised. Refurbishment by replacement, uprating, modifications or change of design of certain key components to extend the life usually requires a substantial amount of capital to be invested. These projects must be economically justified. This thesis focuses on establishing condition assessment techniques for major power equipment such as power transformers. Assessment techniques for instrument transformers and circuit breakers are included, since these are commonly replaced or modified under refurbishment projects. An experimental investigation was carried out to determine the effectiveness of integrating data of two diagnostic techniques i.e. dissolved gas analysis (on-line) and acoustic detection of partial discharges. It was found that there is a correlation between data obtained from an acoustic detection system and an on-line single gas (Hydrogen) analyser. By integrating the data of both on-line monitoring systems, the diagnostic process is further enhanced. In addition, the location of a fixed discharge source was verified by using an acoustic detection system. Further, the sensitivity of the acoustic technique to partial discharge inception voltage, relative to the established electrical detection technique was determined for the experimental arrangement used. The results obtained indicated that this is an effective technique for the evaluation of activity within a transformer structure

    High Voltage DC-biased Oil Type Medium Frequency Transformer; A Green Solution for Series DC Wind Park Concept

    Get PDF
    The electric energy generated by remote offshore wind parks is transported to the consumers using high voltage submarine cables. On the generation site, such transmissions are realized today by collecting the energy produced by several wind turbines in a bulky and expensive transformer placed on a dedicated platform. An alternative solution has been proposed recently, which allows to reduce the installation and maintenance costs by eliminating such a platform. It is suggested to equip each wind turbine in the wind park by an individual DC/DC converter and connect them in series to reach the DC voltage level required for an efficient HVDC energy transportation to the shore. The DC/DC converter is supposed to be a Dual Active Bridge (DAB) converter, which can be made reasonably small to be placed on the wind turbine tower or even in its nacelle. The key element of the converter defining its size and mass is a special transformer, which operates at voltages comprising a high (switching) frequency component superimposed on a high DC offset voltage. DC insulation design of such a transformer and investigation of the effects of a high DC insulation level on the other electromagnetic properties of the transformer is the subject of the present research.In order to verify the concept a prototype of the transformer was built, and its evaluation presented. The unit has been manufactured for the rated power of 50 kW and rated voltages 0.4/5 kV including DC offset of 125 kV and square-shaped oscillations with the frequency of 5 kHz. The magnetic system was made of ferrite material and consisted of 10 shell-type core segments. The magnetic properties have been verified by measuring magnetization and losses at various frequencies in the range 1-10 kHz to cover the operational range of the DAB. The types and dimensions of the windings and their conductors were chosen to minimize the proximity and eddy current effects at higher frequencies. To reduce the size of the transformer and to allow for its efficient cooling, the active part was immersed in oil and cellulose-based materials (paper and pressboard) were used to build the high voltage insulation system. The principles for dimensioning the insulation of the transformer are discussed. The criteria used for selecting insulating distances were based on the consideration of the electric field strength obtained from FEM simulations and using the non-linear Maxwell-Wagner model accounting for local variations of the electric field caused by accumulation of interfacial charges induced by DC stresses. The properties of the materials needed for the calculations were obtained by measuring their dielectric constants and electric conductivities. The methodology used for the measurements conducted for conventional mineral oil and eco-friendly biodegradable transformer oils and, respectively, for oil-impregnated paper/pressboard, is presented. The methodologies used for obtaining parameters of the built transformer prototype needed for its integration in the power electric circuit of the DAB are introduced. A method developed for accurate calculations of the leakage inductance for the shell-type multi core transformers with circular windings is described. Two innovative methods for evaluations of parasitic capacitances based on high frequency equivalent circuits of the transformer are presented. The results of their verifications against performed Frequency Response Analysis measurements and FEM calculations as well as their accuracy are discussed.Thermal performance of the developed transformer prototype is analysed based on the results of computer simulations of heat transfer in its active part under rated load. Identified hot spots and solutions for their elimination are presented.Finally, the expected dimensions, weight, and efficiency of an actual DC/DC converter with the rated parameters corresponding to a 6 MW, 1.8 kV real wind turbine having a 250 kV offset DC voltage are estimated assuming that the developed transformer prototype is scalable. It is shown that the proposed solution allows for installing the full-scale converter having 2.2 Tons in weight and 1.8 m3 in volume on the bottom of the wind turbine’s tower

    On-line measurement of partial discharges in high voltage rotating machines.

    Get PDF
    The on-line condition monitoring of rotating machines is given paramount importance, particularly in Oils and Gas industries where the financial implications of machine shutdown is very high. This project work was directed towards the on-line condition monitoring of high voltage rotating machines by detection of partial discharges (PD) which are indicative of stator insulation degradation. Partial discharge manifests itself in various forms which can be detected using various electrical and non-electrical techniques. The electrical method of detecting small current pulses generated by PD using a Rogowski coil as a sensor has been investigated in this work. Dowding & Mills, who are commercially involved in the condition monitoring of rotating machines, currently use a system called StatorMonotor® for PD detection. The research is intended to develop a new partial discharge detection system that will replace the existing system which is getting obsolete. A three phase partial discharge detection unit was specified, designed and developed that is capable of filtering, amplifying and digitising the discharge signals. The associated data acquisition software was developed using LabVIEW software that was capable of acquiring, displaying and storing the discharge signals. Additional software programs were devised to investigate the removal of external noise. A data compression algorithm was developed to store the discharge data in an efficient manner; also ensuring the backward compatibility to the existing analysis software. Tests were performed in laboratory and on machines on-site and the results are presented. Finally, the data acquisition (DAQ) cards that used the PCMCIA bus was replaced with new USB based DAQ cards with the software modified accordingly. The three phase data acquisition unit developed as a result of this project has produced encouraging results and will be implemented in an industrial environment to evaluate and benchmark its performance with the existing system. Most importantly, a hardware data acquisition platform for the detection of PD pulses has been established within the company which is easily maintainable and expandable to suit any future requirements

    Outdoor Insulation and Gas Insulated Switchgears

    Get PDF
    This book focuses on theoretical and practical developments in the performance of high-voltage transmission line against atmospheric pollution and icing. Modifications using suitable fillers are also pinpointed to improve silicone rubber insulation materials. Very fast transient overvoltage (VFTO) mitigation techniques, along with some suggestions for reliable partial discharge measurements under DC voltage stresses inside gas-insulated switchgears, are addressed. The application of an inductor-based filter for the protective performance of surge arresters against indirect lightning strikes is also discussed

    Selected Papers from 2020 IEEE International Conference on High Voltage Engineering (ICHVE 2020)

    Get PDF
    The 2020 IEEE International Conference on High Voltage Engineering (ICHVE 2020) was held on 6–10 September 2020 in Beijing, China. The conference was organized by the Tsinghua University, China, and endorsed by the IEEE Dielectrics and Electrical Insulation Society. This conference has attracted a great deal of attention from researchers around the world in the field of high voltage engineering. The forum offered the opportunity to present the latest developments and different emerging challenges in high voltage engineering, including the topics of ultra-high voltage, smart grids, and insulating materials
    • …