74,696 research outputs found

    CT diagnosis of early stroke : the initial approach to the new CAD tool based on multiscale estimation of ischemia

    Get PDF
    Background: Computer aided diagnosis (CAD) becomes one of the most important diagnostic tools for urgent states in cerebral stroke and other life-threatening conditions where time plays a crucial role. Routine CT is still diagnostically insufficient in hyperacute stage of stroke that is in the therapeutic window for thrombolytic therapy. Authors present computer assistant of early ischemic stroke diagnosis that supports the radiologic interpretations. A new semantic-visualization system of ischemic symptoms applied to noncontrast, routine CT examination was based on multiscale image processing and diagnostic content estimation. Material/Methods: Evaluation of 95 sets of examinations in patients admitted to a hospital with symptoms suggesting stroke was undertaken by four radiologists from two medical centers unaware of the final clinical findings. All of the consecutive cases were considered as having no CT direct signs of hyperacute ischemia. At the first test stage only the CTs performed at the admission were evaluated independently by radiologists. Next, the same early scans were evaluated again with additional use of multiscale computer-assistant of stroke (MulCAS). Computerized suggestion with increased sensitivity to the subtle image manifestations of cerebral ischemia was constructed as additional view representing estimated diagnostic content with enhanced stroke symptoms synchronized to routine CT data preview. Follow-up CT examinations and clinical features confirmed or excluded the diagnosis of stroke constituting 'gold standard' to verify stroke detection performance. Results: Higher AUC (area under curve) values were found for MulCAS -aided radiological diagnosis for all readers and the differences were statistically significant for random readers-random cases parametric and non-parametric DBM MRMC analysis. Sensitivity and specificity of acute stroke detection for the readers was increased by 30% and 4%, respectively. Conclusions: Routine CT completed with proposed method of computer assisted diagnosis provided noticeable better diagnosis efficiency of acute stroke according to the rates and opinions of all test readers. Further research includes fully automatic detection of hypodense regions to complete assisted indications and formulate the suggestions of stroke cases more objectively. Planned prospective studies will let evaluate more accurately the impact of this CAD tool on diagnosis and further treatment in patients suffered from stroke. It is necessary to determine whether this method is possible to be applied widely

    Neural network-based colonoscopic diagnosis using on-line learning and differential evolution

    Get PDF
    In this paper, on-line training of neural networks is investigated in the context of computer-assisted colonoscopic diagnosis. A memory-based adaptation of the learning rate for the on-line back-propagation (BP) is proposed and used to seed an on-line evolution process that applies a differential evolution (DE) strategy to (re-) adapt the neural network to modified environmental conditions. Our approach looks at on-line training from the perspective of tracking the changing location of an approximate solution of a pattern-based, and thus, dynamically changing, error function. The proposed hybrid strategy is compared with other standard training methods that have traditionally been used for training neural networks off-line. Results in interpreting colonoscopy images and frames of video sequences are promising and suggest that networks trained with this strategy detect malignant regions of interest with accuracy

    ART Neural Networks: Distributed Coding and ARTMAP Applications

    Full text link
    ART (Adaptive Resonance Theory) neural networks for fast, stable learning and prediction have been applied in a variety of areas. Applications include airplane design and manufacturing, automatic target recognition, financial forecasting, machine tool monitoring, digital circuit design, chemical analysis, and robot vision. Supervised ART architectures, called ARTMAP systems, feature internal control mechanisms that create stable recognition categories of optimal size by maximizing code compression while minimizing predictive error in an on-line setting. Special-purpose requirements of various application domains have led to a number of ARTMAP variants, including fuzzy ARTMAP, ART-EMAP, Gaussian ARTMAP, and distributed ARTMAP. ARTMAP has been used for a variety of applications, including computer-assisted medical diagnosis. Medical databases present many of the challenges found in general information management settings where speed, efficiency, ease of use, and accuracy are at a premium. A direct goal of improved computer-assisted medicine is to help deliver quality emergency care in situations that may be less than ideal. Working with these problems has stimulated a number of ART architecture developments, including ARTMAP-IC [1]. This paper describes a recent collaborative effort, using a new cardiac care database for system development, has brought together medical statisticians and clinicians at the New England Medical Center with researchers developing expert systems and neural networks, in order to create a hybrid method for medical diagnosis. The paper also considers new neural network architectures, including distributed ART {dART), a real-time model of parallel distributed pattern learning that permits fast as well as slow adaptation, without catastrophic forgetting. Local synaptic computations in the dART model quantitatively match the paradoxical phenomenon of Markram-Tsodyks [2] redistribution of synaptic efficacy, as a consequence of global system hypotheses.Office of Naval Research (N00014-95-1-0409, N00014-95-1-0657

    Screening of Obstructive Sleep Apnea with Empirical Mode Decomposition of Pulse Oximetry

    Full text link
    Detection of desaturations on the pulse oximetry signal is of great importance for the diagnosis of sleep apneas. Using the counting of desaturations, an index can be built to help in the diagnosis of severe cases of obstructive sleep apnea-hypopnea syndrome. It is important to have automatic detection methods that allows the screening for this syndrome, reducing the need of the expensive polysomnography based studies. In this paper a novel recognition method based on the empirical mode decomposition of the pulse oximetry signal is proposed. The desaturations produce a very specific wave pattern that is extracted in the modes of the decomposition. Using this information, a detector based on properly selected thresholds and a set of simple rules is built. The oxygen desaturation index constructed from these detections produces a detector for obstructive sleep apnea-hypopnea syndrome with high sensitivity (0.8380.838) and specificity (0.8550.855) and yields better results than standard desaturation detection approaches.Comment: Accepted in Medical Engineering and Physic

    Gearbox fault diagnosis under different operating conditions based on time synchronous average and ensemble empirical mode decomposition

    Get PDF
    In this paper, a new method is proposed by combining ensemble empirical mode decomposition (EEMD) with order tracking techniques to analyse the vibration signals from a two stage helical gearbox. The method improves EEMD results in that it overcomes the potential deficiencies and achieves better order spectrum representation for fault diagnosis. Based on the analysis, a diagnostic feature is designed based on the order spectra of extracted IFMs for detection and separation of gearbox faults. Experimental results show this feature is sensitive to different fault severities and robust to the influences from operating conditions and remote sensor locations

    DoctorEye: A clinically driven multifunctional platform, for accurate processing of tumors in medical images

    Get PDF
    Copyright @ Skounakis et al.This paper presents a novel, open access interactive platform for 3D medical image analysis, simulation and visualization, focusing in oncology images. The platform was developed through constant interaction and feedback from expert clinicians integrating a thorough analysis of their requirements while having an ultimate goal of assisting in accurately delineating tumors. It allows clinicians not only to work with a large number of 3D tomographic datasets but also to efficiently annotate multiple regions of interest in the same session. Manual and semi-automatic segmentation techniques combined with integrated correction tools assist in the quick and refined delineation of tumors while different users can add different components related to oncology such as tumor growth and simulation algorithms for improving therapy planning. The platform has been tested by different users and over large number of heterogeneous tomographic datasets to ensure stability, usability, extensibility and robustness with promising results. AVAILABILITY: THE PLATFORM, A MANUAL AND TUTORIAL VIDEOS ARE AVAILABLE AT: http://biomodeling.ics.forth.gr. It is free to use under the GNU General Public License

    Phenotype-based and Self-learning Inter-individual Sleep Apnea Screening with a Level IV Monitoring System

    Get PDF
    Purpose: We propose a phenotype-based artificial intelligence system that can self-learn and is accurate for screening purposes, and test it on a Level IV monitoring system. Methods: Based on the physiological knowledge, we hypothesize that the phenotype information will allow us to find subjects from a well-annotated database that share similar sleep apnea patterns. Therefore, for a new-arriving subject, we can establish a prediction model from the existing database that is adaptive to the subject. We test the proposed algorithm on a database consisting of 62 subjects with the signals recorded from a Level IV wearable device measuring the thoracic and abdominal movements and the SpO2. Results: With the leave-one cross validation, the accuracy of the proposed algorithm to screen subjects with an apnea-hypopnea index greater or equal to 15 is 93.6%, the positive likelihood ratio is 6.8, and the negative likelihood ratio is 0.03. Conclusion: The results confirm the hypothesis and show that the proposed algorithm has great potential to screen patients with SAS
    • …
    corecore