20 research outputs found

    Control and Limit Enforcements for VSC Multi-Terminal HVDC in Newton Power Flow

    Full text link
    This paper proposes a novel method to automatically enforce controls and limits for Voltage Source Converter (VSC) based multi-terminal HVDC in the Newton power flow iteration process. A general VSC MT-HVDC model with primary PQ or PV control and secondary voltage control is formulated. Both the dependent and independent variables are included in the propose formulation so that the algebraic variables of the VSC MT-HVDC are adjusted simultaneously. The proposed method also maintains the number of equations and the dimension of the Jacobian matrix unchanged so that, when a limit is reached and a control is released, the Jacobian needs no re-factorization. Simulations on the IEEE 14-bus and Polish 9241-bus systems are performed to demonstrate the effectiveness of the method.Comment: IEEE PES General Meeting 201

    Power control, fault analysis and protection of series connected diode rectifier and VSC based MTDC topology for offshore application.

    Get PDF
    A multiterminal high-voltage dc (MTDC) system is a promising method for transmitting energy generated from an offshore windfarm (OWF). The creation of MTDC systems became easier by the introduction of voltage source converter (VSC) due to the flexibility and controllability it provides. This technology is newer than the line-commutated converter technology (LCC). Power systems can include any number of windfarms together with converters for both offshore and onshore power conversion. Therefore, this thesis suggests a three-terminal MTDC model of two offshore windfarms and one onshore inverter. The electric energy generated by the two windfarms is rectified into dc and transmitted to the shore using dc cable. Although a VSC or a diode rectifier (DR) can convert ac to dc, a series connection of a VSC and two DRs was proposed at the windfarm side to convert the generated power to achieve controllability of the uncontrollable diode rectifiers and reduces the high cost of badditional VSCs. The proposed topology converts the ac power by dividing the windfarm power so that one-third is the share of the VSC and two-thirds is the share of the DRs. The same topology is used to convert the power produced from the other windfarm. Then, the dc power is transmitted via an undersea dc cable to the onshore location, and is then inverted into ac before it is supplied to the neighbouring ac grid using a grid-side VSC. The proposed topology has many advantages, including a significant save in windfarm VSC (WFVSC) capital cost and a significant reduction in the loss of power of the converter without losing the overall controllability. However, although this topology is suitable for windfarm applications, it might not be suitable for high-voltage direct current (HVDC) that requires bidirectional power flow unless making changes to the topology such as disconnecting the diode rectifiers. Furthermore, fault analyses were investigated, including dc faults and ac faults. Ac faults are categorised as symmetrical or unsymmetrical faults. For comparison purposes, a Simulink model was designed, implemented, and simulated as a reference model. The reference model can operate as VSC-, DR-based MTDC, or a mix of both in a way that any component can be added to or removed from the model at any time during the simulation run. The contribution to the dc fault current from various parts such as dc capacitor and the adjacent feeder was investigated thoroughly, and detailed mathematical formulae were developed to compute fault current from these contributors. In addition, the results of the system response due to both fault types are illustrated and discussed. Both symmetrical and unsymmetrical ac faults were initiated on the onshore grid side, and the system response results are presented for those faults. A generalised control scheme (GCS) was proposed in this thesis, which add the ability the model to control the reactive power and is suitable for both balanced and unbalanced ac faults conditions. A protection against faults was investigated and implemented using dc circuit breakers. The protection system was built to ensure safe operation and to fulfil the grid code requirements. Many grid codes are available and presented in the literature, such as Spanish, British, and Danish; however, a grid code by E.ON was chosen. The protection scheme in VSC-based MTDC networks plays a vital role during dc faults. It is vital that this protection be sensitive, selective, fast, and reliable. Specifically, it must isolate the fault reliably from the system within a short time after the fault occurrence, while maintaining the remaining components of the system in a secure operational condition. For optimal performance, the protection scheme discussed in this thesis employs solid-state circuit breakers. A literature survey relevant to the tasks mentioned above was conducted.PhD in Energy and Powe

    Loss allocation in a distribution system with distributed generation units

    Get PDF
    In Denmark, a large part of the electricity is produced by wind turbines and combined heat and power plants (CHPs). Most of them are connected to the network through distribution systems. This paper presents a new algorithm for allocation of the losses in a distribution system with distributed generation. The algorithm is based on a reduced impedance matrix of the network and current injections from loads and production units. With the algorithm, the effect of the covariance between production and consumption can be evaluated. To verify the theoretical results, a model of the distribution system in Brønderslev in Northern Jutland, including measurement data, has been studied

    State-of-the-art of design and operation of power systems with large amounts of wind power, summary of IEA Wind collaboration

    Get PDF
    An international forum for exchange of knowledge of power system impacts of wind power has been formed under the IEA Implementing Agreement on Wind Energy. The task “Design and Operation of Power Systems with Large Amounts of Wind Power” is analysing existing case studies from different power systems.There are a multitude of studies made and ongoing related to cost of wind integration. However, the results are not easy to compare. This paper summarises the results from 15 case studies
    corecore