315 research outputs found

    Magnetoencephalography

    Get PDF
    This is a practical book on MEG that covers a wide range of topics. The book begins with a series of reviews on the use of MEG for clinical applications, the study of cognitive functions in various diseases, and one chapter focusing specifically on studies of memory with MEG. There are sections with chapters that describe source localization issues, the use of beamformers and dipole source methods, as well as phase-based analyses, and a step-by-step guide to using dipoles for epilepsy spike analyses. The book ends with a section describing new innovations in MEG systems, namely an on-line real-time MEG data acquisition system, novel applications for MEG research, and a proposal for a helium re-circulation system. With such breadth of topics, there will be a chapter that is of interest to every MEG researcher or clinician

    Comparison of blind source separation methods in fast somatosensory-evoked potential detection

    Get PDF
    Blind source separation (BSS) is a promising method for extracting somatosensory-evoked potential (SEP). Although various BSS algorithms are available for SEP extraction, few studies have addressed the performance differences between them. In this study, we compared the performance of a number of typical BSS algorithms on SEP extraction from both computer simulations and clinical experiment. The algorithms we compared included second-order blind identification, estimation of signal parameters via rotation invariance technique, algorithm for multiple unknown signals extraction, joint approximate diagonalization of eigenmatrices, extended infomax, and fast independent component analysis. The performances of these BSS algorithms were determined by the correlation coefficients between the true and the extracted SEP signals. There were significant differences in the performances of the various BSS algorithms in a simulation study. In summary, second-order blind identification using six covariance matrix denoting SOBI6 was recommended as the most appropriate BSS method for fast SEP extraction from noisy backgrounds. Copyright © 2011 by the American Clinical Neurophysiology Society.postprin

    Interference suppression techniques for OPM-based MEG: Opportunities and challenges

    Get PDF
    One of the primary technical challenges facing magnetoencephalography (MEG) is that the magnitude of neuromagnetic fields is several orders of magnitude lower than interfering signals. Recently, a new type of sensor has been developed – the optically pumped magnetometer (OPM). These sensors can be placed directly on the scalp and move with the head during participant movement, making them wearable. This opens up a range of exciting experimental and clinical opportunities for OPM-based MEG experiments, including paediatric studies, and the incorporation of naturalistic movements into neuroimaging paradigms. However, OPMs face some unique challenges in terms of interference suppression, especially in situations involving mobile participants, and when OPMs are integrated with electrical equipment required for naturalistic paradigms, such as motion capture systems. Here we briefly review various hardware solutions for OPM interference suppression. We then outline several signal processing strategies aimed at increasing the signal from neuromagnetic sources. These include regression-based strategies, temporal filtering and spatial filtering approaches. The focus is on the practical application of these signal processing algorithms to OPM data. In a similar vein, we include two worked-through experiments using OPM data collected from a whole-head sensor array. These tutorial-style examples illustrate how the steps for suppressing external interference can be implemented, including the associated data and code so that researchers can try the pipelines for themselves. With the popularity of OPM-based MEG rising, there will be an increasing need to deal with interference suppression. We hope this practical paper provides a resource for OPM-based MEG researchers to build upon

    IFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG)

    Get PDF
    Magnetoencephalography (MEG) records weak magnetic fields outside the human head and thereby provides millisecond-accurate information about neuronal currents supporting human brain function. MEG and electroencephalography (EEG) are closely related complementary methods and should be interpreted together whenever possible. This manuscript covers the basic physical and physiological principles of MEG and discusses the main aspects of state-of-the-art MEG data analysis. We provide guidelines for best practices of patient preparation, stimulus presentation, MEG data collection and analysis, as well as for MEG interpretation in routine clinical examinations. In 2017, about 200 whole-scalp MEG devices were in operation worldwide, many of them located in clinical environments. Yet, the established clinical indications for MEG examinations remain few, mainly restricted to the diagnostics of epilepsy and to preoperative functional evaluation of neurosurgical patients. We are confident that the extensive ongoing basic MEG research indicates potential for the evaluation of neurological and psychiatric syndromes, developmental disorders, and the integrity of cortical brain networks after stroke. Basic and clinical research is, thus, paving way for new clinical applications to be identified by an increasing number of practitioners of MEG. (C) 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V.Peer reviewe

    Applying stochastic spike train theory for high-accuracy human MEG/EEG

    Get PDF
    Background The accuracy of electroencephalography (EEG) and magnetoencephalography (MEG) in measuring neural evoked responses (ERs) is challenged by overlapping neural sources. This lack of accuracy is a severe limitation to the application of ERs to clinical diagnostics. New method We here introduce a theory of stochastic neuronal spike timing probability densities for describing the large-scale spiking activity in neural assemblies, and a spike density component analysis (SCA) method for isolating specific neural sources. The method is tested in three empirical studies with 564 cases of ERs to auditory stimuli from 94 humans, each measured with 60 EEG electrodes and 306 MEG sensors, and a simulation study with 12,300 ERs. Results The first study showed that neural sources (but not non-encephalic artifacts) in individual averaged MEG/EEG waveforms are modelled accurately with temporal Gaussian probability density functions (median 99.7 %–99.9 % variance explained). The following studies confirmed that SCA can isolate an ER, namely the mismatch negativity (MMN), and that SCA reveals inter-individual variation in MMN amplitude. Finally, SCA reduced errors by suppressing interfering sources in simulated cases. Comparison with existing methods We found that gamma and sine functions fail to adequately describe individual MEG/EEG waveforms. Also, we observed that principal component analysis (PCA) and independent component analysis (ICA) does not consistently suppress interference from overlapping brain activity in neither empirical nor simulated cases. Conclusions These findings suggest that the overlapping neural sources in single-subject or patient data can be more accurately separated by applying SCA in comparison to PCA and ICA.Peer reviewe

    Quantitative evaluation of artifact removal in real magnetoencephalogram signals with blind source separation

    Full text link
    The magnetoencephalogram (MEG) is contaminated with undesired signals, which are called artifacts. Some of the most important ones are the cardiac and the ocular artifacts (CA and OA, respectively), and the power line noise (PLN). Blind source separation (BSS) has been used to reduce the influence of the artifacts in the data. There is a plethora of BSS-based artifact removal approaches, but few comparative analyses. In this study, MEG background activity from 26 subjects was processed with five widespread BSS (AMUSE, SOBI, JADE, extended Infomax, and FastICA) and one constrained BSS (cBSS) techniques. Then, the ability of several combinations of BSS algorithm, epoch length, and artifact detection metric to automatically reduce the CA, OA, and PLN were quantified with objective criteria. The results pinpointed to cBSS as a very suitable approach to remove the CA. Additionally, a combination of AMUSE or SOBI and artifact detection metrics based on entropy or power criteria decreased the OA. Finally, the PLN was reduced by means of a spectral metric. These findings confirm the utility of BSS to help in the artifact removal for MEG background activity

    New Approaches for Data-mining and Classification of Mental Disorder in Brain Imaging Data

    Get PDF
    Brain imaging data are incredibly complex and new information is being learned as approaches to mine these data are developed. In addition to studying the healthy brain, new approaches for using this information to provide information about complex mental illness such as schizophrenia are needed. Functional magnetic resonance imaging (fMRI) and magnetoencephalography (MEG) are two well-known neuroimaging approaches that provide complementary information, both of which provide a huge amount of data that are not easily modelled. Currently, diagnosis of mental disorders is based on a patients self-reported experiences and observed behavior over the longitudinal course of the illness. There is great interest in identifying biologically based marker of illness, rather than relying on symptoms, which are a very indirect manifestation of the illness. The hope is that biological markers will lead to earlier diagnosis and improved treatment as well as reduced costs. Understanding mental disorders is a challenging task due to the complexity of brain structure and function, overlapping features between disorders, small numbers of data sets for training, heterogeneity within disorders, and a very large amount of high dimensional data. This doctoral work proposes machine learning and data mining based algorithms to detect abnormal functional network connectivity patterns of patients with schizophrenia and distinguish them from healthy controls using 1) independent components obtained from task related fMRI data, 2) functional network correlations based on resting-state and a hierarchy of tasks, and 3) functional network correlations in both fMRI and MEG data. The abnormal activation patterns of the functional network correlation of patients are characterized by using a statistical analysis and then used as an input to classification algorithms. The framework presented in this doctoral study is able to achieve good characterization of schizophrenia and provides an initial step towards designing an objective biological marker-based diagnostic test for schizophrenia. The methods we develop can also help us to more fully leverage available imaging technology in order to better understand the mystery of the human brain, the most complex organ in the human body

    Automated detection of epileptic ripples in MEG using beamformer-based virtual sensors

    Get PDF
    Objective. In epilepsy, high-frequency oscillations (HFOs) are expressively linked to the seizure onset zone (SOZ). The detection of HFOs in the noninvasive signals from scalp electroencephalography (EEG) and magnetoencephalography (MEG) is still a challenging task. The aim of this study was to automate the detection of ripples in MEG signals by reducing the high-frequency noise using beamformer-based virtual sensors (VSs) and applying an automatic procedure for exploring the time-frequency content of the detected events. Approach. Two-hundred seconds of MEG signal and simultaneous iEEG were selected from nine patients with refractory epilepsy. A two-stage algorithm was implemented. Firstly, beamforming was applied to the whole head to delimitate the region of interest (ROI) within a coarse grid of MEG-VS. Secondly, a beamformer using a finer grid in the ROI was computed. The automatic detection of ripples was performed using the time-frequency response provided by the Stockwell transform. Performance was evaluated through comparisons with simultaneous iEEG signals. Main results. ROIs were located within the seizure-generating lobes in the nine subjects. Precision and sensitivity values were 79.18% and 68.88%, respectively, by considering iEEG-detected events as benchmarks. A higher number of ripples were detected inside the ROI compared to the same region in the contralateral lobe. Significance. The evaluation of interictal ripples using non-invasive techniques can help in the delimitation of the epileptogenic zone and guide placement of intracranial electrodes. This is the first study that automatically detects ripples in MEG in the time domain located within the clinically expected epileptic area taking into account the time-frequency characteristics of the events through the whole signal spectrum. The algorithm was tested against intracranial recordings, the current gold standard. Further studies should explore this approach to enable the localization of noninvasively recorded HFOs to help during pre-surgical planning and to reduce the need for invasive diagnostics.Peer ReviewedPostprint (author's final draft
    corecore