1,127 research outputs found

    Revisiting QRS detection methodologies for portable, wearable, battery-operated, and wireless ECG systems

    Get PDF
    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices.Mohamed Elgendi, Björn Eskofier, Socrates Dokos, Derek Abbot

    Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease : a multicentre observational study

    Get PDF
    Background Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection. We aimed to formally assess the proof-of-concept and accuracy of self-detection of acute coronary artery occlusion by patients during daily life situations and during the very early stages of acute coronary artery occlusion. Methods In this multicentre, observational study, we tested the operational feasibility, specificity, and sensitivity of our RELF method, a three-lead detection system with an automatic algorithm built into a mobile handheld device, for detection of acute coronary artery occlusion. Patients were recruited continuously by physician referrals from three Belgian hospitals until the desired sample size was achieved, had been discharged with planned elective percutaneous coronary intervention, and were able to use a smartphone; they were asked to perform random ambulatory selfrecordings for at least 1 week. A similar self-recording was made before percutaneous coronary intervention and at 60 s of balloon occlusion. Patients were clinically followed up until 1 month after discharge. We quantitatively assessed the operational feasibility with an automated dichotomous quality check of self-recordings. Performance was assessed by analysing the receiver operator characteristics of the ST difference vector magnitude. This trial is registered with ClinicalTrials.gov, number NCT02983396. Findings From Nov 18, 2016, to April 25, 2018, we enrolled 64 patients into the study, of whom 59 (92%) were eligible for self-applications. 58 (91%) of 64 (95% CI 81.0-95.6) patients were able to perform ambulatory self-recordings. Of all 5011 self-recordings, 4567 (91%) were automatically classified as successful within 1 min. In 65 balloon occlusions, 63 index tests at 60 s of occlusion in 55 patients were available. The mean specificity of daily life recordings was 0.96 (0.95-0.97). The mean false positive rate during daily life conditions was 4.19% (95% CI 3.29-5.10). The sensitivity for the target conditions was 0.87 (55 of 63; 95% CI 0.77-0.93) for acute coronary artery occlusion, 0.95 (54 of 57; 0.86-0.98) for acute coronary artery occlusion with electrocardiogram (ECG) changes, and 1.00 (35 of 35) for acute coronary artery occlusion with ECG changes and ST-segment elevation myocardial infarction criteria (STEMI). The index test was more sensitive to detect a 60 s balloon occlusion than the STEMI criteria on 12-lead ECG (87% vs 56%; p<0.0001). The proportion of total variation in study estimates due to heterogeneity between patients (I-2) was low (12.6%). The area under the receiver operator characteristics curve was 0.973 (95% CI 0.956-0.990) for acute coronary artery occlusion at different cutoff values of the magnitude of the ST difference vector. No patients died during the study. Interpretation Self-recording with our RELF device is feasible for most patients with coronary artery disease. The sensitivity and specificity for automatic detection of the earliest phase of acute coronary artery occlusion support the concept of our RELF device for patient empowerment to reduce delay and increase Survival without overloading emergency services. Copyright (C) 2019 The Author(s). Published by Elsevier Ltd

    Emotions in context: examining pervasive affective sensing systems, applications, and analyses

    Get PDF
    Pervasive sensing has opened up new opportunities for measuring our feelings and understanding our behavior by monitoring our affective states while mobile. This review paper surveys pervasive affect sensing by examining and considering three major elements of affective pervasive systems, namely; “sensing”, “analysis”, and “application”. Sensing investigates the different sensing modalities that are used in existing real-time affective applications, Analysis explores different approaches to emotion recognition and visualization based on different types of collected data, and Application investigates different leading areas of affective applications. For each of the three aspects, the paper includes an extensive survey of the literature and finally outlines some of challenges and future research opportunities of affective sensing in the context of pervasive computing

    A Survey Study of the Current Challenges and Opportunities of Deploying the ECG Biometric Authentication Method in IoT and 5G Environments

    Get PDF
    The environment prototype of the Internet of Things (IoT) has opened the horizon for researchers to utilize such environments in deploying useful new techniques and methods in different fields and areas. The deployment process takes place when numerous IoT devices are utilized in the implementation phase for new techniques and methods. With the wide use of IoT devices in our daily lives in many fields, personal identification is becoming increasingly important for our society. This survey aims to demonstrate various aspects related to the implementation of biometric authentication in healthcare monitoring systems based on acquiring vital ECG signals via designated wearable devices that are compatible with 5G technology. The nature of ECG signals and current ongoing research related to ECG authentication are investigated in this survey along with the factors that may affect the signal acquisition process. In addition, the survey addresses the psycho-physiological factors that pose a challenge to the usage of ECG signals as a biometric trait in biometric authentication systems along with other challenges that must be addressed and resolved in any future related research.

    Identification of diseases based on the use of inertial sensors: a systematic review

    Get PDF
    Inertial sensors are commonly embedded in several devices, including smartphones, and other specific devices. This type of sensors may be used for different purposes, including the recognition of different diseases. Several studies are focused on the use of accelerometer for the automatic recognition of different diseases, and it may powerful the different treatments with the use of less invasive and painful techniques for patients. This paper is focused in the systematic review of the studies available in the literature for the automatic recognition of different diseases with accelerometer sensors. The disease that is the most reliably detectable disease using accelerometer sensors, available in 54% of the analyzed studies, is the Parkinson’s disease. The machine learning methods implements for the recognition of Parkinson’s disease reported an accuracy of 94%. Other diseases are recognized in less number that will be subject of further analysis in the future.info:eu-repo/semantics/publishedVersio

    Debatable issues in automated ECG reporting

    Get PDF
    Although automated ECG analysis has been available for many years, there are some aspects which require to be re-assessed with respect to their value while newer techniques which are worthy of review are beginning to find their way into routine use. At the annual International Society of Computerized Electrocardiology conference held in April 2017, four areas in particular were debated. These were a) automated 12 lead resting ECG analysis; b) real time out of hospital ECG monitoring; c) ECG imaging; and d) single channel ECG rhythm interpretation. One speaker presented the positive aspects of each technique and another outlined the more negative aspects. Debate ensued. There were many positives set out for each technique but equally, more negative features were not in short supply, particularly for out of hospital ECG monitoring

    The Design of Digital Heart Rate Meter Using Microcontroller

    Get PDF
    Cardiac tests generally use an electrocardiograph, the results of which are used by medical teams to diagnose heart conditions. Individual ECG examination is held in a health care institution so that it cannot be held independently, considering the high costs and the need for analysis by a specialist.  It is, therefore, necessary to have a functional and portable device to detect heart rate. The heart rate measuring device, equipped with a finger sensor, was designed for adults. The 15-second measurement interval showed the heart rate in one minute and the results were shown on an LCD. The minimum system circuit used ATMega 16

    Classification techniques on computerized systems to predict and/or to detect Apnea: A systematic review

    Get PDF
    Sleep apnea syndrome (SAS), which can significantly decrease the quality of life is associated with a major risk factor of health implications such as increased cardiovascular disease, sudden death, depression, irritability, hypertension, and learning difficulties. Thus, it is relevant and timely to present a systematic review describing significant applications in the framework of computational intelligence-based SAS, including its performance, beneficial and challenging effects, and modeling for the decision-making on multiple scenarios.info:eu-repo/semantics/publishedVersio
    • 

    corecore