29 research outputs found

    Development of temporal phase unwrapping algorithms for depth-resolved measurements using an electronically tuned Ti:Sa laser

    Get PDF
    This thesis is concerned with (a) the development of full-field, multi-axis and phase contrast wavelength scanning interferometer, using an electronically tuned CW Ti:Sa laser for the study of depth resolved measurements in composite materials such as GFRPs and (b) the development of temporal phase unwrapping algorithms for depth re-solved measurements. Item (a) was part of the ultimate goal of successfully extracting the 3-D, depth-resolved, constituent parameters (Young s modulus E, Poisson s ratio v etc.) that define the mechanical behaviour of composite materials like GFRPs. Considering the success of OCT as an imaging modality, a wavelength scanning interferometer (WSI) capable of imaging the intensity AND the phase of the interference signal was proposed as the preferred technique to provide the volumetric displacement/strain fields (Note that displacement/strain fields are analogous to phase fields and thus a phase-contrast interferometer is of particular interest in this case). These would then be passed to the VFM and yield the sought parameters provided the loading scheme is known. As a result, a number of key opto-mechanical hardware was developed. First, a multiple channel (x6) tomographic interferometer realised in a Mach-Zehnder arrangement was built. Each of the three channels would provide the necessary information to extract the three orthogonal displacement/strain components while the other three are complementary and were included in the design in order to maximize the penetration depth (sample illuminated from both sides). Second, a miniature uniaxial (tensile and/or compression) loading machine was designed and built for the introduction of controlled and low magnitude displacements. Last, a rotation stage for the experimental determination of the sensitivity vectors and the re-registration of the volumetric data from the six channels was also designed and built. Unfortunately, due to the critical failure of the Ti:Sa laser data collection using the last two items was not possible. However, preliminary results at a single wavelength suggested that the above items work as expected. Item (b) involved the development of an optical sensor for the dynamic monitoring of wavenumber changes during a full 100 nm scan. The sensor is comprised of a set of four wedges in a Fizeau interferometer setup that became part of the multi-axis interferometer (7th channel). Its development became relevant due to the large amount of mode-hops present during a full scan of the Ti:Sa source. These are associated to the physics of the laser and have the undesirable effect of randomising the signal and thus preventing successful depth reconstructions. The multi-wedge sensor was designed so that it provides simultaneously high wavenumber change resolution and immunity to the large wavenumber jumps from the Ti:Sa. The analysis algorithms for the extraction of the sought wavenumber changes were based on 2-D Fourier transform method followed by temporal phase unwrapping. At first, the performance of the sensor was tested against that of a high-end commercial wavemeter for a limited scan of 1nm. A root mean square (rms) difference in measured wavenumber shift between the two of ∼4 m-1 has been achieved, equivalent to an rms wavelength shift error of ∼0.4 pm. Second, by resampling the interference signal and the wavenumber-change axis onto a uniformly sampled k-space, depth resolutions that are close to the theoretical limits were achieved for scans of up to 37 nm. Access of the full 100 nm range that is characterised by wavelength steps down to picometers level was achieved by introducing a number of improvements to the original temporal phase unwrapping algorithm reported in ref [1] tailored to depth resolved measurements. These involved the estimation and suppression of intensity background artefacts, improvements on the 2-D Fourier transform phase detection based on a previously developed algorithm in ref [2] and finally the introduction of two modifications to the original TPU. Both approaches are adaptive and involve signal re-referencing at regular intervals throughout the scan. Their purpose is to compensate for systematic and non-systematic errors owing to a small error in the value of R (a scaling factor applied to the lower sensitivity wedge phase-change signal used to unwrap the higher sensitivity one), or small changes in R with wavelength due to the possibility of a mismatch in the refractive dispersion curves of the wedges and/or a mismatch in the wedge angles. A hybrid approach combining both methods was proposed and used to analyse the data from each of the four wedges. It was found to give the most robust results of all the techniques considered, with a clear Fourier peak at the expected frequency, with significantly reduced spectral artefacts and identical depth resolutions for all four wedges of 2.2 μm measured at FWHM. The ability of the phase unwrapping strategy in resolving the aforementioned issues was demonstrated by successfully measuring the absolute thickness of four fused silica glasses using real experimental data. The results were compared with independent micrometer measurements and showed excellent agreement. Finally, due to the lack of additional experimental data and in an attempt to justify the validity of the proposed temporal phase unwrapping strategy termed as the hybrid approach, a set of simulations that closely matched the parameters characterising the real experimental data set analysed were produced and were subsequently analysed. The results of this final test justify that the various fixes included in the hybrid approach have not evolved to solve the problems of a particular data set but are rather of general nature thereby, highlighting its importance for PC-WSI applications concerning the processing and analysis of large scans

    Conference on Intelligent Robotics in Field, Factory, Service, and Space (CIRFFSS 1994), volume 1

    Get PDF
    The AIAA/NASA Conference on Intelligent Robotics in Field, Factory, Service, and Space (CIRFFSS '94) was originally proposed because of the strong belief that America's problems of global economic competitiveness and job creation and preservation can partly be solved by the use of intelligent robotics, which are also required for human space exploration missions. Individual sessions addressed nuclear industry, agile manufacturing, security/building monitoring, on-orbit applications, vision and sensing technologies, situated control and low-level control, robotic systems architecture, environmental restoration and waste management, robotic remanufacturing, and healthcare applications

    LDEF: 69 Months in Space. Third Post-Retrieval Symposium, part 1

    Get PDF
    This volume (Part 1 of 3) is a compilation of papers presented at the Third Long Duration Exposure Facility (LDEF) Post-Retrieval Symposium. The papers represent the data analysis of the 57 experiments flown on the LDEF. The experiments include materials, coatings, thermal systems, power and propulsion, science (cosmic ray, interstellar gas, heavy ions, micrometeoroid, etc.), electronics, optics, and life science. In addition, papers on preliminary data analysis of EURECA, EOIM-3, and other spacecraft are included

    Research reports: 1987 NASA/ASEE Summer Faculty Fellowship Program

    Get PDF
    For the 23rd consecutive year, a NASA/ASEE Summer Faculty Fellowship Program was conducted at the Marshall Space Flight Center (MSFC). The program was conducted by the University of Alabama in Huntsville and MSFC during the period 1 June to 7 August 1987. Operated under the auspices of the American Society for Engineering Education, the MSFC program, as well as those at other NASA Centers, was sponsored by the Office of University Affairs, NASA Headquarters, Washington, D.C. The basic objectives of the program are: (1) to further the professional knowledge of qualified engineering and science faculty members; (2) to stimulate an exchange of ideas between participants and NASA; (3) to enrich and refresh the research and teaching activities of the participant's institutions; and (4) to contribute to the research objectives of the NASA Centers. This document is a compilation of Fellow's reports on their research during the Summer of 1987

    Marshall Space Flight Center Research and Technology Report 2018

    Get PDF
    Many of NASAs missions would not be possible if it were not for the investments made in research advancements and technology development efforts. The technologies developed at Marshall Space Flight Center contribute to NASAs strategic array of missions through technology development and accomplishments. The scientists, researchers, and technologists of Marshall Space Flight Center who are working these enabling technology efforts are facilitating NASAs ability to fulfill the ambitious goals of innovation, exploration, and discovery

    Technology 2003: The Fourth National Technology Transfer Conference and Exposition, volume 2

    Get PDF
    Proceedings from symposia of the Technology 2003 Conference and Exposition, Dec. 7-9, 1993, Anaheim, CA, are presented. Volume 2 features papers on artificial intelligence, CAD&E, computer hardware, computer software, information management, photonics, robotics, test and measurement, video and imaging, and virtual reality/simulation

    Pattern Recognition

    Get PDF
    A wealth of advanced pattern recognition algorithms are emerging from the interdiscipline between technologies of effective visual features and the human-brain cognition process. Effective visual features are made possible through the rapid developments in appropriate sensor equipments, novel filter designs, and viable information processing architectures. While the understanding of human-brain cognition process broadens the way in which the computer can perform pattern recognition tasks. The present book is intended to collect representative researches around the globe focusing on low-level vision, filter design, features and image descriptors, data mining and analysis, and biologically inspired algorithms. The 27 chapters coved in this book disclose recent advances and new ideas in promoting the techniques, technology and applications of pattern recognition

    Contribution of a genetic variant of the Wnt receptor LRP6 to synapse vulnerability in the ageing hippocampus

    Get PDF
    Synapse dysfunction and loss represent key pathological hallmarks of Alzheimer's disease (AD). Wnt signalling, in particular through the Wnt co-receptor LRP6, has a critical role in maintaining the structural and functional integrity of synaptic connections in the adult brain. LRP6 dysfunction and deficient Wnt signalling compromise synaptic circuits during ageing, contributing to AD pathogenesis. Wnt signalling has been implicated in AD through a genetic link: A common variant of LRP6 (LRP6-Val) based on a single-nucleotide polymorphism (SNP) confers reduced Wnt signalling activity in cell lines and is associated with an increased risk for late-onset AD. However, it is unknown whether LRP6-Val has a functional impact on synapses in the brain. To investigate the LRP6-Val variant in a physiological context, a novel knock-in mouse model was generated for this study. I examined the structure and function of excitatory hippocampal synapses as well as hippocampus-dependent memory function, using a multidisciplinary approach combining cell biology, imaging, electrophysiological and behavioural studies. My findings demonstrate that the LRP6-Val variant compromises Wnt signalling in an age-dependent manner, leading to pre- and postsynaptic structural and functional defects in the ageing hippocampus. Shrinkage of presynaptic terminals and dendritic spines is accompanied by reduced neurotransmitter release. Upregulation of astrocytes and microglia suggests concomitant neuroinflammation, which may further contribute to synaptic damage. However, global synaptic transmission is preserved and memory function remains unaffected in LRP6-Val knock-in mice up to 14 months of age, possibly due to a homeostatic adjustment of synapse density. Synaptic defects caused by LRP6-Val may exacerbate synapse vulnerability to further toxic insults with advancing age, increasing the risk of a pathological transition towards AD. The results of this study advance our understanding of the role of LRP6-mediated Wnt signalling for synapse maintenance during ageing and strengthen the link between aberrant Wnt signalling, synaptic degeneration and Alzheimer's disease
    corecore