3,164 research outputs found

    A Hybrid Active Filter Using the Backstepping Controller for Harmonic Current Compensation

    Get PDF
    This document presents a new hybrid combination of filters using passive and active elements because of the generalization in the use of non-linear loads that generate harmonics directly affecting the symmetry of energy transmission systems that influence the functioning of the electricity grid and, consequently, the deterioration of power quality. In this context, active power filters represent one of the best solutions for improving power quality and compensating harmonic currents to get a symmetrical waveform. In addition, given the importance and occupation of the transmission network, it is necessary to control the stability of the system. Traditionally, passive filters were used to improve energy quality, but they have endured problems such as resonance, fixed remuneration, etc. In order to mitigate these problems, a hybrid HAPF active power filter is proposed combining a parallel active filter and a passive filter controlled by a backstepping algorithm strategy. This control strategy is compared with two other methods, namely the classical PI control, and the fuzzy logic control in order to verify the effectiveness and the level of symmetry of the backstepping controller proposed for the HAPF. The proposed backstepping controller inspires the notion of stability in Lyapunov’s sense. This work is carried out to improve the performance of the HAPF by the backstepping command. It perfectly compensates the harmonics according to standards. The results of simulations performed under the Matlab/Simulink environment show the efficiency and robustness of the proposed backstepping controller applied on HAPF, compared to other control methods. The HAPF with the backstepping controller shows a significant decrease in the THD harmonic distortion rate

    PFC Topologies for AC to DC Converters in DC Micro-Grid

    Get PDF
    With increasing dominance of renewable energy resources and DC household appliances, the novelty of DC micro grid is attracting significant attention. The key interface between the main supply grid and DC micro grid is AC to DC converter. The conventional AC to DC converter with large output capacitor introduces undesirable power quality problems in the main supply current. It reduces system efficiency due to low power factor and high harmonic distortion. Power Factor Correction (PFC) circuits are used to make supply currents sinusoidal and in-phase with supply voltages. This paper presents different PFC topologies for single phase AC to DC converters which are analyzed for power factor (PF), total harmonic distortion (THD) and system efficiency by varying output power. Two-quadrant shunt active filter topology attains a power factor of 0.999, 3.03% THD and 98% system efficiency. Output voltage regulation of the presented active PFC topologies is simulated by applying a step load. Two-quadrant shunt active filter achieves better output voltage regulation compared to other topologies and can be used as grid interface

    Instantaneous Power Theory with Fourier and Optimal Predictive Controller Design for Shunt Active Power Filter

    Get PDF
    This paper presents a novel harmonic identification algorithm of shunt active power filter for balanced and unbalanced three-phase systems based on the instantaneous power theory called instantaneous power theory with Fourier. Moreover, the optimal design of predictive current controller using an artificial intelligence technique called adaptive Tabu search is also proposed in the paper. These enhancements of the identification and current control parts are the aim of the good performance for shunt active power filter. The good results for harmonic mitigation using the proposed ideas in the paper are confirmed by the intensive simulation using SPS in SIMULINK. The simulation results show that the enhanced shunt active power filter can provide the minimum %THD (Total Harmonic Distortion) of source currents and unity power factor after compensation. In addition, the %THD also follows the IEEE Std.519-1992

    Particle Swarm Optimization Trained Artificial Neural Network to Control Shunt Active Power Filter Based on Multilevel Flying Capacitor Inverter

    Get PDF
    © 2020 by the authors; licensee IIETA, Edmonton, Canada. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/).Shunt Active Power Filters (SAPF) are an emerging power electronics-based technology to mitigate harmonic and improve power quality in distribution grids. The SAPF proposed in this paper is based on three-phase Flying Capacitor Inverter (FCI) with a three-cell per phase topology, which has the advantage to provide voltage stress distribution on the switches. However, controlling the voltage of floating capacitors is a challenging problem for this type of topology. In this paper, a controller based artificial neural networks optimized with particle swarm optimization (ANN-PSO) is proposed to regulate the filter currents to follow the references extracted by the method of synchronous reference frame (SRF). The simulation results showed an enhancement of the power quality with a significant reduction in the THD levels of the current source under various loading conditions, which confirms the effectiveness, and robustness of the proposed control scheme and SAPF topology.Peer reviewe

    Control techniques for active power filters

    Get PDF

    Active damping of a DC network with a constant power load: an adaptive passivity-based control approach

    Get PDF
    This paper proposes a nonlinear, adaptive controller to increase the stability margin of a direct-current (DC) small-scale electrical network containing a constant power load, whose value is unknown. Due to their negative incremental impedance, constant power loads are known to reduce the effective damping of a network, leading to voltage oscillations and even to network collapse. To tackle this problem, we consider the incorporation of a controlled DC-DC power converter between the feeder and the constant power load. The design of the control law for the converter is based on the use of standard Passivity-Based Control and Immersion and Invariance theories. The good performance of the controller is evaluated with numerical simulations.Postprint (author's final draft

    Adaptive-Fuzzy Controller Based Shunt Active Filter for Power Line Conditioners

    Get PDF
    This paper presents a novel Fuzzy Logic Controller (FLC) in conjunction with Phase Locked Loop (PLL) based shunt active filter for Power Line Conditioners (PLCs) to improve the power quality in the distribution system. The active filter is implemented with current controlled Voltage Source Inverter (VSI) for compensating current harmonics and reactive power at the point of common coupling. The VSI gate control switching pulses are derived from proposed Adaptive-Fuzzy-Hysteresis Current Controller (HCC) and this method calculates the hysteresis bandwidth effectively using fuzzy logic.  The bandwidth can be adjusted based on compensation current variation, which is used to optimize the required switching frequency and improves active filter substantially. These shunt active power filter system is investigated and verified under steady and transient-state with non-linear load conditions. This shunt active filter is in compliance with IEEE 519 and IEC 61000-3 recommended harmonic standards

    Interleaved Buck Converter Based Shunt Active Power Filter with Shoot-through Elimination for Power Quality Improvement

    Get PDF
    The “shoot-through” phenomenon defined as the rush of current that occurs while both the devices are ON at the same time of a particular limb is one of the most perilous failure modes encountered in conventional inverter circuits of active power filter (APF). Shoot-through phenomenon has few distinct disadvantages like; it introduces typical ringing, increases temperature rise in power switches, causes higher Electromagnetic Interference (EMI) and reduces the efficiency of the circuit. To avert the “shoot-through”, dead time control could be added, but it deteriorates the harmonic compensation level. This dissertation presents active power filters (APFs) based on interleaved buck (IB) converter. Compared to traditional shunt active power filters, the presented IB APFs have enhanced reliability with no shoot-through phenomenon. The instantaneous active and reactive power (p-q) scheme and instantaneous active and reactive current component (id-iq) control scheme has been implemented to mitigate the source current harmonics. Type-1 and Type-2 fuzzy logic controller with different membership functions (MFs) viz. Triangular, Trapezoidal and Gaussian have been implemented for the optimal harmonic compensation by controlling the dc-link voltage and minimizing the undesirable losses occurred inside the APF. Additionally, the adaptive hysteresis band current controller (AHBCC) is being implemented to get the nearly constant switching frequency. The performance of the control strategies and controllers for the presented IB APF topologies has been evaluated in terms of harmonic mitigation and dc-link voltage regulation under sinusoidal, unbalanced sinusoidal and non-sinusoidal voltage source condition. This dissertation is concerned with the different topologies of 3-phase 4-wire IB APFs viz. split capacitor (2C) topology, 4-leg (4L) topology, transformer based full-bridge IB APF or single capacitor based FB IB APF (1C 3 FB IB APF) and full-bridge IB APF (FB IB APF) for low to medium power application. Moreover, APF topology is now being expanded to multilevel VSIs for high power application. Thanks to flexible modular design, transformerless connection, extended voltage and power output, less maintenance and higher fault tolerance, the cascade inverters are good candidates for active power filters with the utility of high power application. The cascaded FB IB APF is modelled with no shoot-through phenomenon by using multicarrier phase shifted PWM scheme. Extensive simulations have been carried out in the MATLAB / Simulink environment and also verified in the OPAL-RT LAB using OP5142-Spartan 3 FPGA to support the feasibility of presented IB APF topologies, control strategies and controllers during steady and dynamic condition. The performance shows that IB-APF topologies bring the THD of the source current well below 5% adhering to IEEE-519 standard. A comparison has also been made, based on SDP (switch device power) between the IB-APF topologies
    corecore