87 research outputs found

    Wearable electrochemical biosensors in North America

    Get PDF
    Tremendous research and commercialization efforts around the world are focused on developing novel wearable electrochemical biosensors that can noninvasively and continuously screen for biochemical markers in body fluids for the prognosis, diagnosis and management of diseases, as well as the monitoring of fitness. Researchers in North America are leading the development of innovative wearable platforms that can comfortably comply to the human body and efficiently sample fluids such as sweat, interstitial fluids, tear and saliva for the electrochemical detection of biomarkers through various sensing approaches such as potentiometric ion selective electrodes and amperometric enzymatic sensors. We start this review with a historical timeline overviewing the major milestones in the development of wearable electrochemical sensors by North American institutions. We then describe how such research efforts have led to pioneering developments and are driving the advancement and commercialization of wearable electrochemical sensors: from minimally invasive continuous glucose monitors for chronic disease management to non-invasive sweat electrolyte sensors for dehydration monitoring in fitness applications. While many countries across the globe have contributed significantly to this rapidly emerging field, their contributions are beyond the scope of this review. Furthermore, we share our perspective on the promising future of wearable electrochemical sensors in applications spanning from remote and personalized healthcare to wellness

    Microwave Devices for Wearable Sensors and IoT

    Get PDF
    The Internet of Things (IoT) paradigm is currently highly demanded in multiple scenarios and in particular plays an important role in solving medical-related challenges. RF and microwave technologies, coupled with wireless energy transfer, are interesting candidates because of their inherent contactless spectrometric capabilities and for the wireless transmission of sensing data. This article reviews some recent achievements in the field of wearable sensors, highlighting the benefits that these solutions introduce in operative contexts, such as indoor localization and microwave sensing. Wireless power transfer is an essential requirement to be fulfilled to allow these sensors to be not only wearable but also compact and lightweight while avoiding bulky batteries. Flexible materials and 3D printing polymers, as well as daily garments, are widely exploited within the presented solutions, allowing comfort and wearability without renouncing the robustness and reliability of the built-in wearable sensor

    Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    Get PDF
    Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications

    Updates of Wearing Devices (WDs) In Healthcare, And Disease Monitoring

    Get PDF
     With the rising pervasiveness of growing populace, aging and chronic illnesses consistently rising medical services costs, the health care system is going through a crucial change from the conventional hospital focused system to an individual-focused system. Since the twentieth century, wearable sensors are becoming widespread in medical care and biomedical monitoring systems, engaging consistent estimation of biomarkers for checking of the diseased condition and wellbeing, clinical diagnostics and assessment in biological fluids like saliva, blood, and sweat. Recently, the improvements have been centered around electrochemical and optical biosensors, alongside advances with the non-invasive monitoring of biomarkers, bacteria and hormones, etc. Wearable devices have created with a mix of multiplexed biosensing, microfluidic testing and transport frameworks incorporated with flexible materials and body connections for additional created wear ability and effortlessness. These wearables hold guarantee and are fit for a higher understanding of the relationships between analyte focuses inside the blood or non-invasive biofluids and feedback to the patient, which is fundamentally significant in ideal finding, therapy, and control of diseases. In any case, cohort validation studies and execution assessment of wearable biosensors are expected to support their clinical acceptance. In the current review, we discussed the significance, highlights, types of wearables, difficulties and utilizations of wearable devices for biological fluids for the prevention of diseased conditions and real time monitoring of human wellbeing. In this, we sum up the different wearable devices that are developed for health care monitoring and their future potential has been discussed in detail

    A Wearable Fabric-Based RFID Skin Temperature Monitoring Patch

    Get PDF
    This paper presents a novel design of wearable radio frequency identification (RFID) sensor patch make of conductive fabric and integrated on clothes. The wearable RFID with similar design is also implemented on a Polyimide (PI) substrate to show the effectiveness of the system. We also demonstrate the wearable and washable RFID patch by using conductive fabric coil antenna as well as non-conductive fabric substrate. The conductive fabric offers great flexibility and comfortability as it can be sewed into clothes and connect the components of the patch. As a proof of concept, we developed the conductive fabric based RFID for temperature sensing and demonstrate its use by measuring variations in the skin temperature. We observed that the proposed antenna is strain independent during bending. Further, it has the advantage of simplicity and is relatively free from issues such as degradation of performance

    Wearable bio and chemical sensors

    Get PDF
    Chemical and biochemical sensors have experienced tremendous growth in the past decade due to advances in material chemistry combined with the emergence of digital communication technologies and wireless sensor networks (WSNs) [1]. The emergence of wearable chemical and biochemical sensors is a relatively new concept that poses unique challenges to the field of wearable sensing. This is because chemical sensors have a more complex mode of operation, compared to physical transducers, in that they must interact in some manner with specific molecular targets in the sample medium. To understand the challenges in developing wearable chemical and biochemical sensors the traits of these devices will be discussed in this introductory section. Following this the potential parameters of interest are presented and examples of wearable systems are discussed. A range of sampling techniques and methods of chemical sensing are presented along with integration issues and design challenges. Finally, some of the main application areas of this novel technology are discussed

    Detection of exercise adaptations by different specimens analysis

    Get PDF
    This literature review is a compilation of the most used methods to monitoring athletes in training and competition. Blood is certainly the best known and proven methodology and a wide range of markers can be analyzed through it, but it can be difficult to obtain, especially among athletes or people who are afraid of needles. The use of saliva is an interesting alternative especially for the easy and less invasive method of collecting. The saliva infact contains a few of compounds diffused in the plasma, like water, electrolytes, proteins, metabolites and hormones. However, new methods yet poorly understood are slowly catching on; sweat for example, may carry far more information, may provide useful biomarkers that can give indications about the physical state of the body (electrolytes, lactate, creatinine, glucose, proteins, amino acids) and may be easier to stimulate, gather, and analyze than previously thought

    A Passive UHF RFID Dielectric Sensor for Aqueous Electrolytes

    Get PDF
    The one step modification of a commercial RFID sensing tag is demonstrated using polydimethylsiloxane based thin film chemistry to construct reusable passive RFID sensors for changes in the dielectric properties of electrolyte solutions as a function of concentration. The effects of PDMS film thickness were characterized as a function of RFID sensor code value. The output sensor code of the RFMicron RFM2100-AER wireless flexible moisture sensor (taken between 800-860 MHz) was compared to readings taken when the tag was dry and when the tag had a water deposition on the sensor area. The effect of the direct application of liquid water to the tag was to alter the capacitance presented to the integrated chip which auto-tunes to correct for the reactance. By varying the thickness of the PDMS film between the interdigitated sensor and deposited liquid, the sensitivity of the tag to a high dielectric medium could be controlled. Aqueous salt solutions were tested on a 500 m thickness film. It was found that the sensing platform could be used as a means of measuring the concentration of various salt solutions within the range 0-2M, and in turn could be used as a passive UHF RFID dielectric measuring tool. The measurement capability of the platform was subsequently demonstrated using a reduced frequency range (845-865 MHz)
    corecore