27 research outputs found
Miniature fiber-optic force sensor based on low-coherence Fabry-Pérot interferometry for vitreoretinal microsurgery
During vitreoretinal surgery, the surgeon manipulates retinal tissue with tool-to-tissue interaction forces below the human sensory threshold. A force sensor (FS) integrated with conventional surgical tools may significantly improve the surgery outcome by providing tactile feedback to the surgeon. We designed and built a surgical tool integrated with a miniature FS with an outer diameter smaller than 1 mm for vitreoretinal surgery based on low-coherence Fabry–Pérot (FP) interferometry. The force sensing elements are located at the tool tip which is in direct contact with tissue during surgery and the FP cavity length is interrogated by a fiber-optic common-path phase-sensitive optical coherence tomography (OCT) system. We have calibrated the FS's response to axial and lateral forces and conducted experiments to verify that our FS can simultaneously measure both axial and lateral force components
Force Sensing in Arthroscopic Instruments using Fiber Bragg Gratings
Minimally-invasive surgery has revolutionized many medical procedures; however, it also impedes the ability to feel the interaction between the surgical tool and the anatomical part being operated on. In order to address this problem, it is necessary to obtain accurate measurements of the interaction forces exerted on the surgical tools during surgery. These forces can then be manifested to the surgeon via a haptic device or presented visually (visual-force feedback). This thesis describes the use of a fiber optic device to measure and display to the surgeon interaction forces acting on an arthroscopic tool. The sensorization of the tool involves a simple, highly efficient and robust design and is ideally suited for use in a surgical training environment aimed at narrowing the gap between trainees and expert surgeons before the trainees proceed to their first surgery in vivo. The major advantages of using fiber optics include their small size, their local simplicity, their ease of sterilization, and their high sensitivity. In this thesis, a complete low-cost sensing solution is described, including 1) the use of fiber Bragg grating and long period grating sensors, 2) design of a low-cost optical interrogator, 3) high resolution electronic signal processing, and 4) fabrication of the tool using wire EDM, CNC, and 3D metal sintering technologies. The full design of an arthroscopic grasper is presented, along with the preliminary design and manufacturing of an arthroscopic probe and shaver. The designed low-cost system was compared with a commercially-available optical interrogator. The calibration and experimental results for this system are presented and discussed for accuracy and performance of the sensorized tool before and after an axial element was added for increased sensitivity. Sources of error and methods of improvement for the optical system, arthroscopic tool, and testing procedures are discussed to inform the design of future generations of these instruments
Fiber bragg gratings for medical applications and future challenges: A review
In the last decades, fiber Bragg gratings (FBGs) have become increasingly attractive to medical applications due to their unique properties such as small size, biocompatibility, immunity to electromagnetic interferences, high sensitivity and multiplexing capability. FBGs have been employed in the development of surgical tools, assistive devices, wearables, and biosensors, showing great potentialities for medical uses. This paper reviews the FBG-based measuring systems, their principle of work, and their applications in medicine and healthcare. Particular attention is given to sensing solutions for biomechanics, minimally invasive surgery, physiological monitoring, and medical biosensing. Strengths, weaknesses, open challenges, and future trends are also discussed to highlight how FBGs can meet the demands of next-generation medical devices and healthcare system
Fiber Bragg Gratings for Medical Applications and Future Challenges: A Review
[EN] In the last decades, fiber Bragg gratings (FBGs) have become increasingly attractive to medical applications due to their unique properties such as small size, biocompatibility, immunity to electromagnetic interferences, high sensitivity and multiplexing capability. FBGs have been employed in the development of surgical tools, assistive devices, wearables, and biosensors, showing great potentialities for medical uses. This paper reviews the FBG-based measuring systems, their principle of work, and their applications in medicine and healthcare. Particular attention is given to sensing solutions for biomechanics, minimally invasive surgery, physiological monitoring, and medical biosensing. Strengths, weaknesses, open challenges, and future trends are also discussed to highlight how FBGs can meet the demands of next-generation medical devices and healthcare system.This work was supported in part by INAIL (the Italian National Institute for Insurance against Accident at Work), through the BRIC (Bando ricerche in collaborazione) 2018 SENSE-RISC (Sviluppo di abiti intelligENti Sensorizzati per prevenzione e mitigazione di Rischi per la SiCurezza dei lavoratori) Project under Grant ID10/2018, in part by the UCBM (Universita Campus Bio-Medico di Roma) under the University Strategic HOPE (HOspital to the PatiEnt) Project, in part by the EU Framework Program H2020-FETPROACT-2018-01 NeuHeart Project under Grant GA 824071, by FCT/MEC (Fundacao para a Ciencia e Tecnologia) under the Projects UIDB/50008/2020 - UIDP/50008/2020, and by REACT (Development of optical fiber solutions for Rehabilitation and e-Health applications) FCT-IT-LA scientific action.Lo Presti, D.; Massaroni, C.; Leitao, CSJ.; Domingues, MDF.; Sypabekova, M.; Barrera, D.; Floris, I.... (2020). Fiber Bragg Gratings for Medical Applications and Future Challenges: A Review. IEEE Access. 8:156863-156888. https://doi.org/10.1109/ACCESS.2020.3019138S156863156888
Force-Sensing-Based Multi-Platform Robotic Assistance for Vitreoretinal Surgery
Vitreoretinal surgery aims to treat disorders of the retina, vitreous body, and macula, such as retinal detachment, diabetic retinopathy, macular hole, epiretinal membrane and retinal vein occlusion. Challenged by several technical and human limitations, vitreoretinal practice currently ranks amongst the most demanding fields in ophthalmic surgery. Of vitreoretinal procedures, membrane peeling is the most common to be performed, over 0.5 million times annually, and among the most prone to complications. It requires an extremely delicate tissue manipulation by various micron scale maneuvers near the retina despite the physiological hand tremor of the operator. In addition, to avoid injuries, the applied forces on the retina need to be kept at a very fine level, which is often well below the tactile sensory threshold of the surgeon. Retinal vein cannulation is another demanding procedure where therapeutic agents are injected into occluded retinal veins. The feasibility of this treatment is limited due to challenges in identifying the moment of venous puncture, achieving cannulation and maintaining it throughout the drug delivery period.
Recent advancements in medical robotics have significant potential to address most of the challenges in vitreoretinal practice, and therefore to prevent traumas, lessen complications, minimize intra-operative surgeon effort, maximize surgeon comfort, and promote patient safety. This dissertation presents the development of novel force-sensing tools that can easily be used on various robotic platforms, and robot control methods to produce integrated assistive surgical systems that work in partnership with surgeons against the current limitations in vitreoretinal surgery, specifically focusing on membrane peeling and vein cannulation procedures. Integrating high sensitivity force sensing into the ophthalmic instruments enables precise quantitative monitoring of applied forces. Auditory feedback based upon the measured forces can inform (and warn) the surgeon quickly during the surgery and help prevent injury due to excessive forces. Using these tools on a robotic platform can attenuate hand tremor of the surgeon, which effectively promotes tool manipulation accuracy. In addition, based upon certain force signatures, the robotic system can precisely identify critical instants, such as the venous puncture in retinal vein cannulation, and actively guide the tool towards clinical targets, compensate any involuntary motion of the surgeon, or generate additional motion that will make the surgical task easier. The experimental results using two distinct robotic platforms, the Steady-Hand Eye Robot and Micron, in combination with the force-sensing ophthalmic instruments, show significant performance improvement in artificial dry phantoms and ex vivo biological tissues
An Intraoperative Force Perception and Signal Decoupling Method on Capsulorhexis Forceps
Force perception on medical instruments is critical for understanding the
mechanism between surgical tools and tissues for feeding back quantized force
information, which is essential for guidance and supervision in robotic
autonomous surgery. Especially for continuous curvilinear capsulorhexis (CCC),
it always lacks a force measuring method, providing a sensitive, accurate, and
multi-dimensional measurement to track the intraoperative force. Furthermore,
the decoupling matrix obtained from the calibration can decorrelate signals
with acceptable accuracy, however, this calculating method is not a strong way
for thoroughly decoupling under some sensitive measuring situations such as the
CCC. In this paper, a three-dimensional force perception method on
capsulorhexis forceps by installing Fiber Bragg Grating sensors (FBGs) on
prongs and a signal decoupling method combined with FASTICA is first proposed
to solve these problems. According to experimental results, the measuring range
is up to 1 N (depending on the range of wavelength shifts of sensors) and the
resolution on x, y, and z axial force is 0.5, 0.5, and 2 mN separately. To
minimize the coupling effects among sensors on measuring multi-axial forces, by
unitizing the particular parameter and scaling the corresponding vector in the
mixing matrix and recovered signals from FastICA, the signals from sensors can
be decorrelated and recovered with the errors on axial forces decreasing up to
50% least. The calibration and calculation can also be simplified with half the
parameters involved in the calculation. Experiments on thin sheets and in vitro
porcine eyes were performed, and it was found that the tearing forces were
stable and the time sequence of tearing forceps was stationary or first-order
difference stationary during roughly circular crack propagating.Comment: 12pages, 17 figure
From teleoperation to autonomous robot-assisted microsurgery: A survey
Robot-assisted microsurgery (RAMS) has many benefits compared to traditional microsurgery. Microsurgical platforms with advanced control strategies, high-quality micro-imaging modalities and micro-sensing systems are worth developing to further enhance the clinical outcomes of RAMS. Within only a few decades, microsurgical robotics has evolved into a rapidly developing research field with increasing attention all over the world. Despite the appreciated benefits, significant challenges remain to be solved. In this review paper, the emerging concepts and achievements of RAMS will be presented. We introduce the development tendency of RAMS from teleoperation to autonomous systems. We highlight the upcoming new research opportunities that require joint efforts from both clinicians and engineers to pursue further outcomes for RAMS in years to come
Recent advances in biomedical photonic sensors: a focus on optical-fibre-based sensing
In this invited review, we provide an overview of the recent advances in biomedical pho tonic sensors within the last five years. This review is focused on works using optical-fibre technology, employing diverse optical fibres, sensing techniques, and configurations applied in several medical fields. We identified technical innovations and advancements with increased implementations of optical-fibre sensors, multiparameter sensors, and control systems in real applications. Examples of outstanding optical-fibre sensor performances for physical and biochemical parameters are covered, including diverse sensing strategies and fibre-optical probes for integration into medical instruments such as catheters, needles, or endoscopes.This work was supported by Ministerio de Ciencia e Innovación and Agencia Estatal de Investigación (PID2019-107270RB-C21/AEI/10.13039/501100011033), and TeDFeS Project (RTC-2017- 6321-1) co-funded by European FEDER funds. M.O. and J.F.A. received funding from Ministerio de Ciencia, Innovación y Universidades of Spain under Juan de la Cierva-Formación and Juan de la Cierva-Incorporación grants, respectively. P.R-V. received funding from Ministerio de Educación, Cultura y Deporte of Spain under PhD grant FPU2018/02797