2,667 research outputs found
Wireless body sensor networks for health-monitoring applications
This is an author-created, un-copyedited version of an article accepted for publication in
Physiological Measurement. The publisher is
not responsible for any errors or omissions in this version of the manuscript or any version
derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/0967-3334/29/11/R01
Wearable devices for remote vital signs monitoring in the outpatient setting: an overview of the field
Early detection of physiological deterioration has been shown to improve patient outcomes. Due to recent improvements in technology, comprehensive outpatient vital signs monitoring is now possible. This is the first review to collate information on all wearable devices on the market for outpatient physiological monitoring.
A scoping review was undertaken. The monitors reviewed were limited to those that can function in the outpatient setting with minimal restrictions on the patientâs normal lifestyle, while measuring any or all of the vital signs: heart rate, ECG, oxygen saturation, respiration rate, blood pressure and temperature.
A total of 270 papers were included in the review. Thirty wearable monitors were examined: 6 patches, 3 clothing-based monitors, 4 chest straps, 2 upper arm bands and 15 wristbands. The monitoring of vital signs in the outpatient setting is a developing field with differing levels of evidence for each monitor. The most common clinical application was heart rate monitoring. Blood pressure and oxygen saturation measurements were the least common applications. There is a need for clinical validation studies in the outpatient setting to prove the potential of many of the monitors identified.
Research in this area is in its infancy. Future research should look at aggregating the results of validity and reliability and patient outcome studies for each monitor and between different devices. This would provide a more holistic overview of the potential for the clinical use of each device
Wearable technology and the cardiovascular system: the future of patient assessment
The past decade has seen a dramatic rise in consumer technologies able to monitor a variety of cardiovascular parameters. Such devices initially recorded markers of exercise, but now include physiological and health-care focused measurements. The public are keen to adopt these devices in the belief that they are useful to identify and monitor cardiovascular disease. Clinicians are therefore often presented with health app data accompanied by a diverse range of concerns and queries. Herein, we assess whether these devices are accurate, their outputs validated, and whether they are suitable for professionals to make management decisions. We review underpinning methods and technologies and explore the evidence supporting the use of these devices as diagnostic and monitoring tools in hypertension, arrhythmia, heart failure, coronary artery disease, pulmonary hypertension, and valvular heart disease. Used correctly, they might improve health care and support research
The 2023 wearable photoplethysmography roadmap
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology
BioWatch: Estimation of Heart and Breathing Rates from Wrist Motions
Continued developments of sensor technology including hardware miniaturization and increased sensitivity have enabled the development of less intrusive methods to monitor physiological parameters during daily life. In this work, we present methods to recover cardiac and respiratory parameters using accelerometer and gyroscope sensors on the wrist. We demonstrate accurate measurements in a controlled laboratory study where participants (n = 12) held three different positions (standing up, sitting down and lying down) under relaxed and aroused conditions. In particular, we show it is possible to achieve a mean absolute error of 1.27 beats per minute (STD: 3.37) for heart rate and 0.38 breaths per minute (STD: 1.19) for breathing rate when comparing performance with FDA-cleared sensors. Furthermore, we show comparable performance with a state-of-the-art wrist-worn heart rate monitor, and when monitoring heart rate of three individuals during two consecutive nights of in-situ sleep measurements.National Science Foundation (U.S.) (CCF-1029585)Samsung (Firm). Think Tank TeamMIT Media Lab Consortiu
Morphic sensors for respiratory parameters estimation : validation against overnight polysomnography
Effective monitoring of respiratory disturbances during sleep requires a sensor capable of accurately capturing chest movements or airflow displacement. Gold-standard monitoring of sleep and breathing through polysomnography achieves this task through dedicated chest/abdomen bands, thermistors, and nasal flow sensors, and more detailed physiology, evaluations via a nasal mask, pneumotachograph, and airway pressure sensors. However, these measurement approaches can be invasive and time-consuming to perform and analyze. This work compares the performance of a non-invasive wearable stretchable morphic sensor, which does not require direct skin contact, embedded in a t-shirt worn by 32 volunteer participants (26 males, 6 females) with sleep-disordered breathing who performed a detailed, overnight in-laboratory sleep study. Direct comparison of computed respiratory parameters from morphic sensors versus traditional polysomnography had approximately 95% (95 Âą 0.7) accuracy. These findings confirm that novel wearable morphic sensors provide a viable alternative to non-invasively and simultaneously capture respiratory rate and chest and abdominal motions
Recommended from our members
Digital phenotyping through multimodal, unobtrusive sensing
The growing adoption of multimodal wearable and mobile devices, such as smartphones and wrist-worn watches has generated an increase in the collection of physiological and behavioural data at scale. This digital phenotyping data enables researchers to make inferences regarding usersâ physical and mental health at scale, for the first time. However, translating this data into actionable insights requires computational approaches that turn unlabelled, multimodal time-series sensor data into validated measures that can be interpreted at scale.
This thesis describes the derivation of novel computational methods that leverage digital phenotyping data from wearable devices in large-scale populations to infer physical behaviours. These methods combine insights from signal processing, data mining and machine learning alongside domain knowledge in physical activity and sleep epidemiology. First, the inference of sleeping windows in free-living conditions through a heart rate sensing approach is explored. This algorithm is particularly valuable in the absence of ground truth or sleep diaries given its simplicity, adaptability and capacity for personalization. I then explore multistage sleep classification through combined movement and cardiac wearable sensing and machine learning. Further, I demonstrate that postural changes detected through wrist accelerometers can inform habitual behaviours and are valuable complements to traditional, intensity-based physical activity metrics. I then leverage the concomitant responses of heart rate to physical activity that can be captured through multimodal wearable sensors through a self-supervised training task. The resulting embeddings from this task are shown to be useful for the downstream classification of demographic factors, BMI, energy expenditure and cardiorespiratory fitness. Finally, I describe a deep learning model for the adaptive inference of cardiorespiratory fitness (VO2max) using wearable data in free living conditions. I demonstrate the robustness of the model in a large UK population and show the modelsâ adaptability by evaluating its performance in a subset of the population with repeated measures ~6 years after the original recordings.
Together, this work increases the potential of multimodal wearable and mobile sensors for physical activity and behavioural inferences in population studies. In particular, this thesis showcases the potential of using wearable devices to make valuable physical activity, sleep and fitness inferences in large cohort studies. Given the nature of the data collected and the fact that most of this data is currently generated by commercial providers and not research institutes, laying the foundations for responsible data governance and ethical use of these technologies will be critical to building trust and enabling the development of the field of digital phenotyping.I was funded by GlaxoSmithKline and the Engineering and Physical Sciences Research Council. I was also supported by the Alan Turing Institute through their Enrichment Scheme
Communication system for a tooth-mounted RF sensor used for continuous monitoring of nutrient intake
In this Thesis, the communication system of a wearable device that monitors the userâs diet is studied. Based in a novel RF metamaterial-based mouth sensor, different decisions have to be made concerning the systemâs technologies, such as the power source options for the device, the wireless technology used for communications and the method to obtain data from the sensor. These issues, along with other safety rules and regulations, are reviewed, as the first stage of development of the Food-Intake Monitoring projectOutgoin
- âŚ