116,322 research outputs found

    Flow compensating pressure regulator

    Get PDF
    An apparatus for regulating pressure of treatment fluid during ophthalmic procedures is described. Flow sensing and pressure regulating diaphragms are used to modulate a flow control valve. The pressure regulating diaphragm is connected to the flow control valve to urge the valve to an open position due to pressure being applied to the diaphragm by bias means such as a spring. The flow sensing diaphragm is mechanically connected to the flow control valve and urges it to an opened position because of the differential pressure on the diaphragm generated by a flow of incoming treatment fluid through an orifice in the diaphragm. A bypass connection with a variable restriction is connected in parallel relationship to the orifice to provide for adjusting the sensitivity of the flow sensing diaphragm. A multiple lever linkage system is utilized between the center of the second diaphragm and the flow control valve to multiply the force applied to the valve by the other diaphragm and reverse the direction of the force

    Calibrating pressure switch

    Get PDF
    A pressure switch assembly comprising a body portion and a switch mechanism having a contact element operable between opposite limit positions is described. A diaphragm chamber is provided in the body portion which mounts therein a system diaphragm and a calibration diaphragm which are of generally the same configuration and having outer faces conforming to the inner and outer walls of the diaphragm chamber. The space between the inner faces of the diaphragms defines a first chamber section and the space between the outer face of one of the diaphragms and the outer wall of the diaphragm chamber defines a second chamber section. The body portion includes a system pressure port communicating with one of the chamber sections and a calibration pressure port communicating with the other chamber section. An actuator connected to one of the diaphragms and the contact element of the switch operates upon pressure change in the diaphragm sections to move said contact element between limit positions

    Measured opening characteristics of an electromagnetically opened diaphragm for the Langley expansion tunnel

    Get PDF
    Results from an experimental study of the opening characteristics of an electromagnetically opened, 15.24 cm diameter diaphragm are presented. This diaphragm consists of a polyester film bonded to a preformed wire and is opened by passing a current pulse (capacitor discharge) through the wire. The diaphragm separates the acceleration section of the expansion tunnel from the nozzle so that the nozzle may be at a lower pressure than the acceleration section prior to a test. Opening times and cleanness of the opened area were examined for dependence on diaphragm thickness, on wire diameter, on technique of bonding the wire to the diaphragm, and on voltage and energy level of the energy source. Time histories of the pitot pressure measured at the expansion-tunnel nozzle entrance location are presented for (1) no diaphragm, (2) a flow-opened diaphragm, and (3) an electromagnetically opened diaphragm

    TFE coating extends life of flexible metal compressor diaphragm

    Get PDF
    Tetrafluoroethylene /TFE/ aerosol sprayed onto entire surface of diaphragm acts as film lubricant and permits diaphragm to slide between upper and lower plates in a reciprocating compressor. Flexing occurs over an area rather than about a single line of action and operating life of diaphragm is more than quadrupled

    Noninvasive assessment of inspiratory muscle neuromechanical coupling during inspiratory threshold loading

    Get PDF
    Diaphragm neuromechanical coupling (NMC), which reflects the efficiency of conversion of neural activation to transdiaphragmatic pressure (Pdi), is increasingly recognized to be a useful clinical index of diaphragm function and respiratory mechanics in neuromuscular weakness and cardiorespiratory disease. However, the current gold standard assessment of diaphragm NMC requires invasive measurements of Pdi and crural diaphragm electromyography (oesEMGdi), which complicates the measurement of diaphragm NMC in clinical practice. This is the first study to compare invasive measurements of diaphragm NMC (iNMC) using the relationship between Pdi and oesEMGdi, with noninvasive assessment of NMC (nNMC) using surface mechanomyography (sMMGlic) and electromyography (sEMGlic) of lower chest wall inspiratory muscles. Both invasive and noninvasive measurements were recorded in twelve healthy adult subjects during an inspiratory threshold loading protocol. A linear relationship between noninvasive sMMGlic and sEMGlic measurements was found, resulting in little change in nNMC with increasing inspiratory load. By contrast, a curvilinear relationship between invasive Pdi and oesEMGdi measurements was observed, such that there was a progressive increase in iNMC with increasing inspiratory threshold load. Progressive recruitment of lower ribcage muscles, serving to enhance the mechanical advantage of the diaphragm, may explain the more linear relationship between sMMGlic and sEMGlic (both representing lower intercostal plus costal diaphragm activity) than between Pdi and crural oesEMGdi. Noninvasive indices of NMC derived from sEMGlic and sMMGlic may prove to be useful indices of lower chest wall inspiratory muscle NMC, particularly in settings that do not have access to invasive measures of diaphragm function.Peer ReviewedPostprint (published version

    Flexible parylene actuator for micro adaptive flow control

    Get PDF
    This paper describes the first flexible parylene electrostatic actuator valves intended for micro adaptive flow control for the future use on the wings of micro-air-vehicle (MAV). The actuator diaphragm is made of two layers of parylene membranes with offset vent holes. Without electrostatic actuation, air can move freely from one side of the skin to the other side through the vent holes. With actuation, these vent holes are sealed and the airflow is controlled. The membrane behaves as a complete diaphragm. We have successfully demonstrated this function using a 2-mm x 2-mm parylene diaphragm electrostatic actuator valves. This work also includes the novel anti-stiction technology that is crucial to make such large-area parylene actuator diaphragm with the combined use of anti-stiction posts, self-assembled monolayers (SAM), surface roughening, and bromine trifluoride (BrFe) dry etching. With the help of SAM treatment, the operating voltage is lowered from 30 volts to 13 volts. The load deflection method is then used to measure the effective thickness of the composite diaphragm. The flexible parylene diaphragm can be deflected up to 100 μm when 150 Torr of pressure is applied. The result is fitted into a theoretical model and yields an effective thickness of 5.9 μm, which is agreeable with the actual thickness of 5.6 μm, thus proves the functionality of the device

    The effect of hypodynamia on the structure of the intraorganic blood vessels and the capacity of the blood stream in the diaphragm of white rats

    Get PDF
    The effect of hypodynamia on the vascular system of white rats with diaphragm deprivation was investigated. Morphological changes in the intraorganic blood stream of the diaphragm were determined. The capacity of the intraorganic vascular flow within the diaphragm muscles was established

    Collapsible pistons for light-gas guns

    Get PDF
    Moving and expandable parts of gun consist of pump-tube diaphragm, piston, launch-tube diaphragm, and saboted projectile. As a result of improved piston design, pressure cycle has been significantly improved by smoother buildup, increasing muzzle velocities up to 50%

    Early changes in rat diaphragm biology with mechanical ventilation

    Get PDF
    To better characterize the effects of 24-hour mechanical ventilation on diaphragm, the expression of myogenic transcription factors, myosin heavy chains, and sarcoplasmic/endoplasmic reticulum calcium-ATPase pumps was examined in rats. In the diaphragm of mechanically ventilated animals, the mRNA of MyoD, myosin heavy chain-2a and -2b, and sarcoplasmic/endoplasmic reticulum calcium-ATPase-1a decreased, whereas myogenin mRNA increased. In the diaphragm of anesthetized and spontaneously breathing rats, only the mRNA of MyoD and myosin heavy chain-2a decreased. MyoD and myogenin protein expression followed the changes at the mRNA, whereas the myosin heavy chain isoforms did not change. Parallel experiments involving the gastrocnemius were performed to assess the relative contribution of muscle shortening versus immobilization-induced deconditioning on muscle regulatory factor expression. Passive shortening produced no additional effects compared with immobilization-induced deconditioning. The overall changes followed a remarkably similar pattern except for MyoD protein expression, which increased in the gastrocnemius and decreased in the diaphragm while its mRNA diminished in both muscles. The early alterations in the expression of muscle protein and regulatory factors may serve as underlying molecular basis for the impaired diaphragm function seen after 24 hours of mechanical ventilation. Whether immobilization-induced deconditioning and/or passive shortening play a role in these alterations could not be fully unraveled
    corecore