135 research outputs found
Smart Healthy Schools: An IoT-enabled concept for multi-room dynamic air quality control
Smart Healthy Schools (SHS) are a new paradigm in building engineering and infection risk control in school buildings where the disciplines of Indoor Air Quality (IAQ), IoT (Internet of Things) and Artificial Intelligence (AI) merge together. In the post-pandemic era, equipping schools with a network of smart IoT sensors has become critical to aspire for the optimal control of the IAQ and lowering the airborne infection risk of several pathogens, indirectly related to cumulated human emitted CO2 levels over time. Thermal energy waste in winter due to improved air renewal remains of major concern but can be well monitored within a SHS monitoring architecture thanks to the flexibility of the LoRaWAN protocol able to process also a large amount of energy and climatic data at room and building scale. In this work, we report the design of the AulaSicura platform, an IoT control system co-designed by the main author and Gizero Energie to implement the SHS paradigm via clearly visible (and audible) alarm signalling in existing and new school buildings. The cloud-based LoRa system is capable of continuous and simultaneous monitoring of a variety of sensors and IAQ parameters including indoor/oudoor temperatures, rel. humidities and human-emitted excess CO2. The multi-room monitoring concept of indoor-CO2 levels allows centralized control of natural ventilation levels in individual classrooms and can handle (quasi)-real-time data, relevant for data post-processing and future developments in (quasi)-real-rime assessment of IAQ and infection risk levels at single room scale. The sensor network is also extensible to up to one thousand of classrooms per LoRa-node allowing centralized control of entire school districts at an urban scale. Moreover, through Modbus-LoRa I/O converters, AulaSicura can also control the same amount of mechanical ventilation units per node either in pure or hybrid mechanical ventilation modes
Neuronal intermediate filament IgGs in CSF: Autoimmune Axonopathy Biomarkers
Objectives: To describe CSF-defined neuronal intermediate filament (NIF) autoimmunity. Methods: NIF-IgG CSF-positive patients (41, 0.03% of 118599 tested, 1996-2019) were included (serum was neither sensitive nor specific). Criteria-based patient NIF-IgG staining of brain and myenteric NIFs was detected by indirect immunofluorescence assay (IFA); NIF-specificity was confirmed by cell-based assays (CBAs, alpha internexin, neurofilament light [NF-L]), heavy-[NF-H] chain). Results: Sixty-one percent of 41 patients were men, median age, 61 years (range, 21-88). Syndromes were encephalopathy predominant (23), cerebellar ataxia predominant (11), or myeloradiculoneuropathies (7). MRI abnormalities (T2 hyperintensities of brain, spinal cord white matter tracts. and peripheral nerve axons) and neurophysiologic testing (EEG, EMG, evoked potentials) co-localized with clinical neurological phenotypes (multifocal in 29%). Thirty patients (73%) had 65 1 immunological perturbation: cancer (paraneoplastic), 22; systemic infection (parainfectious [including ehrlichosis, 3] or HIV), 7; checkpoint-inhibitor cancer immunotherapy, 4; other, 5. Cancers were as follows: neuroendocrine-lineage carcinomas, 12 (small cell, 6; Merkel cell, 5; pancreatic, 1 [11/12 had NF-L-IgG detected, versus 8/29 others, P = 0.0005]) and other, 11. Onset was predominantly subacute (92%) and accompanied by inflammatory CSF (75%), and immunotherapy response (77%). In contrast, CSF controls (15684 total) demonstrated NIF-IgG negativity (100% of test validation controls), and low frequencies of autoimmune diagnoses (20% of consecutively referred clinical specimens) and neuroendocrine-lineage carcinoma diagnosis (3.1% vs. 30% of NIF cases), P < 0.0001. Median NF-L protein concentration was higher in 8 NF-L-IgG-positive patients (median, 6718 ng/L) than 16 controls. Interpretation: Neurological autoimmunity, defined by CSF-detected NIF-IgGs, represents a continuum of treatable axonopathies, sometimes paraneoplastic or parainfectious
Laser decoating of DLC films for tribological applications
Damaged DLC coatings usually require remanufacturing of the entire coated components starting from an industrial chemical de-coating step. Alternatively, a complete or local coating repair can be considered. To pursue this approach, however, a local coating removal is needed as first operation. In this context, controlled decoating based on laser sources can be a suitable and clean alternative to achieve a pre-fixed decoating depth with high accuracy. In the present study, we investigated a laser-based decoating process executed on multilayered DLC films for advanced tribological applications (deposited via a hybrid PVD/PE-CVD technique). The results were acquired via multifocal optical digital microscopy (MF-ODM), which allowed high-resolution 3D surface reconstruction as well as digital profilometry of the lasered and unlasered surface. The study identifies the most critical process parameters which influence the effective decoating depth and the post-decoating surface roughness. In particular, the role of pulse overlap (decomposed along orthogonal directions), laser fluence, number of lasing passes and assist gas is discussed in text. A first experimental campaign was designed to identify the best conditions to obtain full decoating of the DLC + DLC:Cr layers. It was observed that decreasing the marking speed to 200 mm/s was necessary to obtain a sufficient pulse overlap and a nearly planar ablation profile. By operating with microsecond pulses and 1 J/cm2 (fairly above the ablation threshold), less than 10 passes were needed to obtain full decoating of the lasered area with an etching rate of 1.1 μm/loop. Further experiments were then executed in order to minimise the roughness of the rest surface with the best value found at around 0.2 μm. Limited oxidation but higher Ra values were observed in Ar atmosphere
The Coronary Sinus Reducer; 5-year Dutch experience
Background: Refractory angina is a growing and major health-care problem affecting millions of patients with coronary artery disease worldwide. The Coronary Sinus Reducer (CSR) is a device that may be considered for the relief of symptoms of refractory angina. It causes increased venous pressure leading to a dilatation of arterioles and reduced arterial vascular resistance in the sub-endocardium. This study describes the 5‑year Dutch experience regarding safety and efficacy of the CSR. Methods: One hundred and thirty-two patients with refractory angina were treated with the CSR. The primary efficacy endpoint of the study was Canadian Cardiovascular Society (CCS) class improvement between baseline and 6‑month follow-up. The primary safety endpoint was successful CSR implantation in the absence of any device-related events. Results: Eighty-five patients (67%) showed improvement of at least 1 CCS class and 43 patients (34%) of at least 2 classes. Mean CCS class improved from 3.17 ± 0.61 to 2.12 ± 1.07 after implantation (P < 0.001). The CSR was successfully implanted in 99% of the patients and only minor complications during implantation were reported. Conclusion: The CSR is a simple, safe, and effective option for most patients with refractory angina. However, approximately thirty percent of the patients showed no benefit after implantation. Future studies should focus on the exact underlying mechanisms of action and reasons for non-response to better identify patients that could benefit most from this therapy
Less bleeding by omitting aspirin in non-ST-segment elevation acute coronary syndrome patients: rationale and design of the LEGACY study
BackgroundEarly aspirin withdrawal, also known as P2Y12-inhibitor monotherapy, following percutaneous coronary intervention (PCI) for non-ST-segment elevation acute coronary syndrome (NSTE-ACS) can reduce bleeding without a trade-off in efficacy. Still the average daily bleeding risk is highest during the first months and it remains unclear if aspirin can be omitted immediately following PCI.MethodsThe LEGACY study is an open-label, multicenter randomized controlled trial evaluating the safety and efficacy of immediate P2Y12-inhibitor monotherapy versus dual antiplatelet therapy (DAPT) for 12 months in 3,090 patients. Patients are randomized immediately following successful PCI for NSTE-ACS to 75-100 mg aspirin once daily versus no aspirin. The primary hypothesis is that immediately omitting aspirin is superior to DAPT with respect to major or minor bleeding defined as Bleeding Academic Research Consortium type 2, 3, or 5 bleeding, while maintaining noninferiority for the composite of all-cause mortality, myocardial infarction and stroke compared to DAPT.ConclusionsThe LEGACY study is the first randomized study that is specifically designed to evaluate the impact of immediately omitting aspirin, and thus treating patients with P2Y12-inhibitor monotherapy, as compared to DAPT for 12 months on bleeding and ischemic events within 12 months following PCI for NSTE-ACS.Cardiolog
Appropriate use criteria for optical coherence tomography guidance in percutaneous coronary interventions Recommendations of the working group of interventional cardiology of the Netherlands Society of Cardiology
Introduction: Optical coherence tomography (OCT) enables detailed imaging of the coronary wall, lumen and intracoronary implanted devices. Responding to the lack of specific appropriate use criteria (AUC) for this technique, we conducted a literature review and a procedure for appropriate use criteria. Methods: Twenty-one of all 184 members of the Dutch Working Group on Interventional Cardiology agreed to evaluate 49 pre-specified cases. During a meeting, factual indications were established whereupon members individually rated indications on a 9-point scale, with the opportunity to substantiate their scoring. Results: Twenty-six indications were rated ‘Appropriate’, eighteen indications ‘May be appropriate’, and five ‘Rarely appropriate’. Use of OCT was unanimously considered ‘Appropriate’ in stent thrombosis, and ‘Appropriate’ for guidance in PCI, especially in distal left main coronary artery and proximal left anterior descending coronary artery, unexplained angiographic abnormalities, and use of bioresorbable vascular scaffold (BVS). OCT was considered ‘Rarely Appropriate’ on top of fractional flow reserve (FFR) for treatment indication, assessment of strut coverage, bypass anastomoses or assessment of proximal left main coronary artery. Conclusions: The use of OCT in stent thrombosis is unanimously considered ‘Appropriate’ by these experts. Varying degrees of consensus exists on the appropriate use of OCT in other settings
Prevention of congenital malformations and other adverse pregnancy outcomes with 4.0 mg of folic acid : community-based randomized clinical trial in Italy and the Netherlands
Background: In 2010 a Cochrane review confirmed that folic acid (FA) supplementation prevents the first- and second-time occurrence of neural tube defects (NTDs). At present some evidence from observational studies supports the hypothesis that FA supplementation can reduce the risk of all congenital malformations (CMs) or the risk of a specific and selected group of them, namely cardiac defects and oral clefts. Furthermore, the effects on the prevention of prematurity, foetal growth retardation and pre-eclampsia are unclear.Although the most common recommendation is to take 0.4 mg/day, the problem of the most appropriate dose of FA is still open.The aim of this project is to assess the effect a higher dose of peri-conceptional FA supplementation on reducing the occurrence of all CMs. Other aims include the promotion of pre-conceptional counselling, comparing rates of selected CMs, miscarriage, pre-eclampsia, preterm birth, small for gestational age, abruptio placentae.Methods/Design: This project is a joint effort by research groups in Italy and the Netherlands. Women of childbearing age, who intend to become pregnant within 12 months are eligible for the studies. Women are randomly assigned to receive 4 mg of FA (treatment in study) or 0.4 mg of FA (referent treatment) daily. Information on pregnancy outcomes are derived from women-and-physician information.We foresee to analyze the data considering all the adverse outcomes of pregnancy taken together in a global end point (e.g.: CMs, miscarriage, pre-eclampsia, preterm birth, small for gestational age). A total of about 1,000 pregnancies need to be evaluated to detect an absolute reduction of the frequency of 8%. Since the sample size needed for studying outcomes separately is large, this project also promotes an international prospective meta-analysis.Discussion: The rationale of these randomized clinical trials (RCTs) is the hypothesis that a higher intake of FA is related to a higher risk reduction of NTDs, other CMs and other adverse pregnancy outcomes. Our hope is that these trials will act as catalysers, and lead to other large RCTs studying the effects of this supplementation on CMs and other infant and maternal outcomes.Trial registration: Italian trial: ClinicalTrials.gov Identifier: NCT01244347.Dutch trial: Dutch Trial Register ID: NTR3161
- …