227 research outputs found
Ethnic disparities in people accessing FreeStyle Libre in the UK: insights from the Association of British Clinical Diabetologists audit
The long-term impact of glucose monitoring with the FreeStyle Libre on glycaemic control and hypoglycaemia awareness in people with type 1 diabetes: Insights from the Association of British Clinical Diabetologists national audit
AimsTo investigate the change in glycated haemoglobin (HbA1c), hypoglycaemia awareness and diabetes-related distress in people with type 1 diabetes (T1D) using FreeStyle Libre (FSL) over a 2-year follow-up period.MethodsFSL user data from U.K wide hospitals collected during routine clinical care were analysed. People living with T1D were categorised into four groups based on the duration of follow-up. Group I ( 2 years, n = 642). The t-test was used to compare the baseline and follow-up HbA1c, GOLD score (a measure of hypoglycaemia awareness) and diabetes-related distress scale (DDS score) (quality of life measure).ResultsThe study consisted of 16,834 people, with follow-up data available for 8,629 participants. The change in HbA1c, GOLD and DDS score from baseline within the follow-up sub-groups (group I vs group II vs group III vs group IV) was HbA1c (−6 vs −6 vs −4 vs −4 mmol/mol; p < 0.001) (−0.55 vs −0.55 vs −0.37 vs −0.37 %), GOLD score (−0.31 vs −0.45 vs −0.26 vs −0.42; p < 0.0001 group I, II, IV and p  0.07 group III), and DDS score(−0.59 vs −0.58 vs −0.63 vs −0.50; p < 0.001), respectively.ConclusionsIn people with T1D, FSL use resulted in a sustained improvement in HbA1c, hypoglycaemia awareness and diabetes-related distress for over two years
The HIPASS Catalogue - II. Completeness, Reliability, and Parameter Accuracy
The HI Parkes All Sky Survey (HIPASS) is a blind extragalactic HI 21-cm
emission line survey covering the whole southern sky from declination -90 to
+25. The HIPASS catalogue (HICAT), containing 4315 HI-selected galaxies from
the region south of declination +2, is presented in Meyer et al. (2004a, Paper
I). This paper describes in detail the completeness and reliability of HICAT,
which are calculated from the recovery rate of synthetic sources and follow-up
observations, respectively. HICAT is found to be 99 per cent complete at a peak
flux of 84 mJy and an integrated flux of 9.4 Jy km/s. The overall reliability
is 95 per cent, but rises to 99 per cent for sources with peak fluxes >58 mJy
or integrated flux > 8.2 Jy km/s. Expressions are derived for the uncertainties
on the most important HICAT parameters: peak flux, integrated flux, velocity
width, and recessional velocity. The errors on HICAT parameters are dominated
by the noise in the HIPASS data, rather than by the parametrization procedure.Comment: Accepted for publication in MNRAS. 12 pages, 11 figures. Paper with
higher resolution figures can be downloaded from http://hipass.aus-vo.or
What is the progenitor of the Type Ia SN 2014J?
We report the deepest radio interferometric observations of the closest Type Ia supernova in decades, SN 2014J, which exploded in the nearby galaxy M 82. These observations
represent, together with radio observations of SNe 2011fe, the most sensitive radio studies of a Type Ia SN ever. We constrain the mass-loss rate from the progenitor system of
SN 2014J lower than 7.0 × 10^(−10) M yr^(−1) (for a wind speed of 100 km s^(−1) ). Our deep upper limits favor a double-degenerate scenario–involving two WD stars–for the progenitor system of SN 2014J, as such systems have less circumstellar gas than our upper limits. By contrast,
most single-degenerate scenarios, i.e., the wide family of progenitor systems where a red giant, main-sequence, or sub-giant star donates mass to a exploding white dwarf, are ruled out by our observations. The evidence from SNe 2011fe and 2014J points in the direction of a double-degenerate scenario for both
Modelling chemistry in the nocturnal boundary layer above tropical rainforest and a generalised effective nocturnal ozone deposition velocity for sub-ppbv NOx conditions
Measurements of atmospheric composition have been made over a remote rainforest landscape. A box model has previously been demonstrated to model the observed daytime chemistry well. However the box model is unable to explain the nocturnal measurements of relatively high [NO] and [O3], but relatively low observed [NO2]. It is shown that a one-dimensional (1-D) column model with simple O3 -NOx chemistry and a simple representation of vertical transport is able to explain the observed nocturnal concentrations and predict the likely vertical profiles of these species in the nocturnal boundary layer (NBL). Concentrations of tracers carried over from the end of the night can affect the atmospheric chemistry of the following day. To ascertain the anomaly introduced by using the box model to represent the NBL, vertically-averaged NBL concentrations at the end of the night are compared between the 1-D model and the box model. It is found that, under low to medium [NOx] conditions (NOx <1 ppbv), a simple parametrisation can be used to modify the box model deposition velocity of ozone, in order to achieve good agreement between the box and 1-D models for these end-of-night concentrations of NOx and O3. This parametrisation would could also be used in global climate-chemistry models with limited vertical resolution near the surface. Box-model results for the following day differ significantly if this effective nocturnal deposition velocity for ozone is implemented; for instance, there is a 9% increase in the following day’s peak ozone concentration. However under medium to high [NOx] conditions (NOx > 1 ppbv), the effect on the chemistry due to the vertical distribution of the species means no box model can adequately represent chemistry in the NBL without modifying reaction rate constants
Injectable semaglutide and reductions in HbA1c and weight in the real world in people switched from alternative glucagon-like peptide-1 receptor agonists
The ABCD semaglutide audit was designed to capture the routine clinical outcomes of people commenced on semaglutide in the UK. Previous work showed differential reductions in HbA1c and weight dependent on previous glucagon-like peptide-1 receptor agonist (GLP-1RA) exposure. The analysis, in this research letter, shows that decreases in HbA1c and weight associated with semaglutide occur irrespective of previous GLP-1RA use. However, HbA1c reductions were less if switched from dulaglutide or liraglutide and weight changes were attenuated if switched from dulaglutide or exenatide, potentially suggesting differing potencies between GLP-1RAs. Dedicated studies with head-to-head comparisons are needed to confirm these findings
VAST: An ASKAP Survey for Variables and Slow Transients
The Australian Square Kilometre Array Pathfinder (ASKAP) will give us an
unprecedented opportunity to investigate the transient sky at radio
wavelengths. In this paper we present VAST, an ASKAP survey for Variables and
Slow Transients. VAST will exploit the wide-field survey capabilities of ASKAP
to enable the discovery and investigation of variable and transient phenomena
from the local to the cosmological, including flare stars, intermittent
pulsars, X-ray binaries, magnetars, extreme scattering events, interstellar
scintillation, radio supernovae and orphan afterglows of gamma ray bursts. In
addition, it will allow us to probe unexplored regions of parameter space where
new classes of transient sources may be detected. In this paper we review the
known radio transient and variable populations and the current results from
blind radio surveys. We outline a comprehensive program based on a multi-tiered
survey strategy to characterise the radio transient sky through detection and
monitoring of transient and variable sources on the ASKAP imaging timescales of
five seconds and greater. We also present an analysis of the expected source
populations that we will be able to detect with VAST.Comment: 29 pages, 8 figures. Submitted for publication in Pub. Astron. Soc.
Australi
Tissue Sampling Methods and Standards for Vertebrate Genomics
The recent rise in speed and efficiency of new sequencing technologies have facilitated high-throughput sequencing, assembly and analyses of genomes, advancing ongoing efforts to analyze genetic sequences across major vertebrate groups. Standardized procedures in acquiring high quality DNA and RNA and establishing cell lines from target species will facilitate these initiatives. We provide a legal and methodological guide according to four standards of acquiring and storing tissue for the Genome 10K Project and similar initiatives as follows: four-star (banked tissue/cell cultures, RNA from multiple types of tissue for transcriptomes, and sufficient flash-frozen tissue for 1 mg of DNA, all from a single individual);three-star (RNA as above and frozen tissue for 1 mg of DNA); two-star (frozen tissue for at least 700 μg of DNA); and one-star (ethanol-preserved tissue for 700 μg of DNA or less of mixed quality). At a minimum, all tissues collected for the Genome 10K and other genomic projects should consider each species’ natural history and follow institutional and legal requirements. Associated documentation should detail as much information as possible about provenance to ensure representative sampling and subsequent sequencing. Hopefully, the procedures outlined here will not only encourage success in the Genome 10K Project but also inspire the adaptation of standards by other genomic projects, including those involving other biota
- …